Equivalent Diameter using Reynolds Number Solution

STEP 0: Pre-Calculation Summary
Formula Used
Equivalent Diameter = (Reynolds Number*Dynamic Viscosity)/Density*Velocity
De = (Re*μ)/ρ*v
This formula uses 5 Variables
Variables Used
Equivalent Diameter - (Measured in Meter) - Equivalent diameter is the diameter equivalent to the given value.
Reynolds Number - Reynolds number is the ratio of inertial forces to viscous forces within a fluid which is subjected to relative internal movement due to different fluid velocities.
Dynamic Viscosity - (Measured in Pascal Second) - Dynamic viscosity of a fluid is the measure of its resistance to flow when an external force is applied.
Density - (Measured in Kilogram per Cubic Meter) - Density of a material shows the denseness of that material in a specific given area. This is taken as mass per unit volume of a given object.
Velocity - (Measured in Meter per Second) - Velocity is a vector quantity (it has both magnitude and direction) and is the rate of change of the position of an object with respect to time.
STEP 1: Convert Input(s) to Base Unit
Reynolds Number: 5000 --> No Conversion Required
Dynamic Viscosity: 0.6 Poise --> 0.06 Pascal Second (Check conversion here)
Density: 997 Kilogram per Cubic Meter --> 997 Kilogram per Cubic Meter No Conversion Required
Velocity: 60 Meter per Second --> 60 Meter per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
De = (Re*μ)/ρ*v --> (5000*0.06)/997*60
Evaluating ... ...
De = 18.0541624874624
STEP 3: Convert Result to Output's Unit
18.0541624874624 Meter --> No Conversion Required
FINAL ANSWER
18.0541624874624 18.05416 Meter <-- Equivalent Diameter
(Calculation completed in 00.020 seconds)

Credits

Created by Vaibhav Mishra
DJ Sanghvi College of Engineering (DJSCE), Mumbai
Vaibhav Mishra has created this Calculator and 300+ more calculators!
Verified by Ayush gupta
University School of Chemical Technology-USCT (GGSIPU), New Delhi
Ayush gupta has verified this Calculator and 10+ more calculators!

4 Filtration Calculators

Equivalent Diameter using Reynolds Number
Go Equivalent Diameter = (Reynolds Number*Dynamic Viscosity)/Density*Velocity
Fraction of Cycle Time used for Cake Formation
Go Fraction of Cycle Time Used For Cake Formation = Time Required For Cake Formation/Total Cycle Time
Total Cycle Time Required for Cake Formation
Go Total Cycle Time = Time Required For Cake Formation/Fraction of Cycle Time Used For Cake Formation
Time Required for Cake Formation
Go Time Required For Cake Formation = Fraction of Cycle Time Used For Cake Formation*Total Cycle Time

Equivalent Diameter using Reynolds Number Formula

Equivalent Diameter = (Reynolds Number*Dynamic Viscosity)/Density*Velocity
De = (Re*μ)/ρ*v

What is Dynamic Viscosity ?

The dynamic viscosity η (η = "eta") is a measure of the viscosity of a fluid . The higher the viscosity, the thicker (less liquid) the fluid; the lower the viscosity, the thinner (more liquid) it is. SI unit of dynamic viscosity: [η] = Pascal-second

How to Calculate Equivalent Diameter using Reynolds Number?

Equivalent Diameter using Reynolds Number calculator uses Equivalent Diameter = (Reynolds Number*Dynamic Viscosity)/Density*Velocity to calculate the Equivalent Diameter, The Equivalent Diameter using Reynolds Number calculator is used for calculation of equivalent diameter using the definition of Reynolds Number for Packed bed. Equivalent Diameter is denoted by De symbol.

How to calculate Equivalent Diameter using Reynolds Number using this online calculator? To use this online calculator for Equivalent Diameter using Reynolds Number, enter Reynolds Number (Re), Dynamic Viscosity (μ), Density (ρ) & Velocity (v) and hit the calculate button. Here is how the Equivalent Diameter using Reynolds Number calculation can be explained with given input values -> 18.05416 = (5000*0.06)/997*60.

FAQ

What is Equivalent Diameter using Reynolds Number?
The Equivalent Diameter using Reynolds Number calculator is used for calculation of equivalent diameter using the definition of Reynolds Number for Packed bed and is represented as De = (Re*μ)/ρ*v or Equivalent Diameter = (Reynolds Number*Dynamic Viscosity)/Density*Velocity. Reynolds number is the ratio of inertial forces to viscous forces within a fluid which is subjected to relative internal movement due to different fluid velocities, Dynamic viscosity of a fluid is the measure of its resistance to flow when an external force is applied, Density of a material shows the denseness of that material in a specific given area. This is taken as mass per unit volume of a given object & Velocity is a vector quantity (it has both magnitude and direction) and is the rate of change of the position of an object with respect to time.
How to calculate Equivalent Diameter using Reynolds Number?
The Equivalent Diameter using Reynolds Number calculator is used for calculation of equivalent diameter using the definition of Reynolds Number for Packed bed is calculated using Equivalent Diameter = (Reynolds Number*Dynamic Viscosity)/Density*Velocity. To calculate Equivalent Diameter using Reynolds Number, you need Reynolds Number (Re), Dynamic Viscosity (μ), Density (ρ) & Velocity (v). With our tool, you need to enter the respective value for Reynolds Number, Dynamic Viscosity, Density & Velocity and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!