Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 500+ more calculators!
Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 500+ more calculators!

5 Other formulas that you can solve using the same Inputs

Equivalent Reactance From Secondary Side When Equivalent Impedance From Secondary Side Is Given
Equivalent reactance from secondary=sqrt((Equivalent Impedance of transformer from secondary*Equivalent Impedance of transformer from secondary)-(Equivalent resistance from Secondary*Equivalent resistance from Secondary)) GO
Equivalent Impedance Of Transformer From Secondary Side
Equivalent Impedance of transformer from secondary=sqrt((Equivalent resistance from Secondary*Equivalent resistance from Secondary)+(Equivalent reactance from secondary*Equivalent reactance from secondary)) GO
Secondary Leakage Reactance When Equivalent Reactance From Secondary Side Is Given
Secondary leakage Reactance=Equivalent reactance from secondary-(Primary leakage Reactance*Voltage Transformation Ratio*Voltage Transformation Ratio) GO
Voltage Transformation Ratio When Equivalent Reactance From Secondary Side Is Given
Voltage Transformation Ratio=sqrt((Equivalent reactance from secondary-Secondary leakage Reactance)/Primary leakage Reactance) GO
Reactance Of Primary In Secondary When Equivalent Reactance From Secondary Side Is Given
Reactance of Primary in Secondary=Equivalent reactance from secondary-Secondary leakage Reactance GO

2 Other formulas that calculate the same Output

Equivalent Resistance From Secondary Side When Primary Winding Resistance
Equivalent resistance from Secondary=Resistance of Secondary winding+(Resistance of primary winding/(Voltage Transformation Ratio*Voltage Transformation Ratio)) GO
Equivalent Resistance Of Transformer From Secondary Side
Equivalent resistance from Secondary=Resistance of Primary winding in Secondary+Resistance of Secondary winding GO

Equivalent Resistance From Secondary Side When Equivalent Impedance From Secondary Side Is Given Formula

Equivalent resistance from Secondary=sqrt((Equivalent Impedance of transformer from secondary*Equivalent Impedance of transformer from secondary)-(Equivalent reactance from secondary*Equivalent reactance from secondary))
R02=sqrt((Z02*Z02)-(X02*X02))
More formulas
Equivalent Resistance Of Transformer From Primary Side GO
Equivalent Resistance Of Transformer From Secondary Side GO
Equivalent Resistance From Primary Side When Secondary Winding Resistance GO
Equivalent Resistance From Secondary Side When Primary Winding Resistance GO
Equivalent Resistance From Primary Side When Equivalent Impedance From Primary Side Is Given GO

What type of winding is used in a transformer?

In core type, we wrap the primary, and secondary windings on the outside limbs, and in shell type, we place the primary and secondary windings on the inner limbs. We use concentric type windings in core type transformer. We place a low voltage winding near the core. However, to reduce leakage reactance, windings can be interlaced.

How to Calculate Equivalent Resistance From Secondary Side When Equivalent Impedance From Secondary Side Is Given?

Equivalent Resistance From Secondary Side When Equivalent Impedance From Secondary Side Is Given calculator uses Equivalent resistance from Secondary=sqrt((Equivalent Impedance of transformer from secondary*Equivalent Impedance of transformer from secondary)-(Equivalent reactance from secondary*Equivalent reactance from secondary)) to calculate the Equivalent resistance from Secondary, The Equivalent Resistance From Secondary Side When Equivalent Impedance From Secondary Side Is Given formula is defined as the sum of Secondary Winding Resistance and Resistance of Primary winding in Secondary. Equivalent resistance from Secondary and is denoted by R02 symbol.

How to calculate Equivalent Resistance From Secondary Side When Equivalent Impedance From Secondary Side Is Given using this online calculator? To use this online calculator for Equivalent Resistance From Secondary Side When Equivalent Impedance From Secondary Side Is Given, enter Equivalent Impedance of transformer from secondary (Z02) and Equivalent reactance from secondary (X02) and hit the calculate button. Here is how the Equivalent Resistance From Secondary Side When Equivalent Impedance From Secondary Side Is Given calculation can be explained with given input values -> NaN = sqrt((2*2)-(3*3)).

FAQ

What is Equivalent Resistance From Secondary Side When Equivalent Impedance From Secondary Side Is Given?
The Equivalent Resistance From Secondary Side When Equivalent Impedance From Secondary Side Is Given formula is defined as the sum of Secondary Winding Resistance and Resistance of Primary winding in Secondary and is represented as R02=sqrt((Z02*Z02)-(X02*X02)) or Equivalent resistance from Secondary=sqrt((Equivalent Impedance of transformer from secondary*Equivalent Impedance of transformer from secondary)-(Equivalent reactance from secondary*Equivalent reactance from secondary)). Equivalent Impedance of transformer from secondary side is total of Equivalent reactance of transformer from Secondary side and Equivalent resistance of transformer from Secondary side and Equivalent reactance from secondary side is the total reactance of secondary winding.
How to calculate Equivalent Resistance From Secondary Side When Equivalent Impedance From Secondary Side Is Given?
The Equivalent Resistance From Secondary Side When Equivalent Impedance From Secondary Side Is Given formula is defined as the sum of Secondary Winding Resistance and Resistance of Primary winding in Secondary is calculated using Equivalent resistance from Secondary=sqrt((Equivalent Impedance of transformer from secondary*Equivalent Impedance of transformer from secondary)-(Equivalent reactance from secondary*Equivalent reactance from secondary)). To calculate Equivalent Resistance From Secondary Side When Equivalent Impedance From Secondary Side Is Given, you need Equivalent Impedance of transformer from secondary (Z02) and Equivalent reactance from secondary (X02). With our tool, you need to enter the respective value for Equivalent Impedance of transformer from secondary and Equivalent reactance from secondary and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Equivalent resistance from Secondary?
In this formula, Equivalent resistance from Secondary uses Equivalent Impedance of transformer from secondary and Equivalent reactance from secondary. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Equivalent resistance from Secondary=Resistance of Primary winding in Secondary+Resistance of Secondary winding
  • Equivalent resistance from Secondary=Resistance of Secondary winding+(Resistance of primary winding/(Voltage Transformation Ratio*Voltage Transformation Ratio))
Share Image
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!