Flow of Lubricant into Clearance of Journal given Outflow and Flow Ratio Variable Solution

STEP 0: Pre-Calculation Summary
Formula Used
Flow of Lubricant = Flow Ratio Variable*Out-Flow of Lubricant
Q = FRV*Qs
This formula uses 3 Variables
Variables Used
Flow of Lubricant - (Measured in Cubic Meter per Second) - The Flow of Lubricant can be defined as the amount of lubricant flowing per unit time between the surfaces.
Flow Ratio Variable - The Flow Ratio Variable Value is defined as the ratio of flow of lubricant into the clearance by the journal to outflow of lubricant.
Out-Flow of Lubricant - (Measured in Cubic Meter per Second) - The Out-Flow of Lubricant is defined as the flow of the lubricant outside the assembly.
STEP 1: Convert Input(s) to Base Unit
Flow Ratio Variable: 4.2 --> No Conversion Required
Out-Flow of Lubricant: 380 Cubic Millimeter per Second --> 3.8E-07 Cubic Meter per Second (Check conversion here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Q = FRV*Qs --> 4.2*3.8E-07
Evaluating ... ...
Q = 1.596E-06
STEP 3: Convert Result to Output's Unit
1.596E-06 Cubic Meter per Second -->1596 Cubic Millimeter per Second (Check conversion here)
FINAL ANSWER
1596 Cubic Millimeter per Second <-- Flow of Lubricant
(Calculation completed in 00.020 seconds)

Credits

Created by Vaibhav Malani
National Institute of Technology (NIT), Tiruchirapalli
Vaibhav Malani has created this Calculator and 600+ more calculators!
Verified by Anshika Arya
National Institute Of Technology (NIT), Hamirpur
Anshika Arya has verified this Calculator and 2500+ more calculators!

4 Flow of Lubricant Calculators

Flow of Lubricant in Clearance of Journal in Terms of Flow Variable
Go Flow of Lubricant into Clearance Space = (Flow Variable*Radius of Journal*Radial clearance for bearing*Journal Speed*Axial Length of Bearing)/(2*pi)
Flow of Lubricant in Terms of Pumping Power
Go Flow of lubricant from step bearing = Pumping Power for Bearing/(Inlet Pressure for Bearing-Outlet Pressure for Bearing)
Flow of Lubricant in Terms of Pumping Power and Pressure of Lubricating Oil
Go Flow of lubricant from step bearing = Pumping Power for Bearing/Pressure of Lubricating Oil
Flow of Lubricant into Clearance of Journal given Outflow and Flow Ratio Variable
Go Flow of Lubricant = Flow Ratio Variable*Out-Flow of Lubricant

Flow of Lubricant into Clearance of Journal given Outflow and Flow Ratio Variable Formula

Flow of Lubricant = Flow Ratio Variable*Out-Flow of Lubricant
Q = FRV*Qs

What is Sliding Contact Bearing?

The sliding contact bearings in which the sliding action is along the circumference of a circle or an arc of a circle and carrying radial loads are known as journal or sleeve bearings.

How to Calculate Flow of Lubricant into Clearance of Journal given Outflow and Flow Ratio Variable?

Flow of Lubricant into Clearance of Journal given Outflow and Flow Ratio Variable calculator uses Flow of Lubricant = Flow Ratio Variable*Out-Flow of Lubricant to calculate the Flow of Lubricant, The Flow of Lubricant into Clearance of Journal given Outflow and Flow Ratio Variable formula is defined as the product of outflow of lubricant to flow ratio variable. Flow of Lubricant is denoted by Q symbol.

How to calculate Flow of Lubricant into Clearance of Journal given Outflow and Flow Ratio Variable using this online calculator? To use this online calculator for Flow of Lubricant into Clearance of Journal given Outflow and Flow Ratio Variable, enter Flow Ratio Variable (FRV) & Out-Flow of Lubricant (Qs) and hit the calculate button. Here is how the Flow of Lubricant into Clearance of Journal given Outflow and Flow Ratio Variable calculation can be explained with given input values -> 1.6E+12 = 4.2*3.8E-07.

FAQ

What is Flow of Lubricant into Clearance of Journal given Outflow and Flow Ratio Variable?
The Flow of Lubricant into Clearance of Journal given Outflow and Flow Ratio Variable formula is defined as the product of outflow of lubricant to flow ratio variable and is represented as Q = FRV*Qs or Flow of Lubricant = Flow Ratio Variable*Out-Flow of Lubricant. The Flow Ratio Variable Value is defined as the ratio of flow of lubricant into the clearance by the journal to outflow of lubricant & The Out-Flow of Lubricant is defined as the flow of the lubricant outside the assembly.
How to calculate Flow of Lubricant into Clearance of Journal given Outflow and Flow Ratio Variable?
The Flow of Lubricant into Clearance of Journal given Outflow and Flow Ratio Variable formula is defined as the product of outflow of lubricant to flow ratio variable is calculated using Flow of Lubricant = Flow Ratio Variable*Out-Flow of Lubricant. To calculate Flow of Lubricant into Clearance of Journal given Outflow and Flow Ratio Variable, you need Flow Ratio Variable (FRV) & Out-Flow of Lubricant (Qs). With our tool, you need to enter the respective value for Flow Ratio Variable & Out-Flow of Lubricant and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!