G21 Parameter in Terms of Y Parameters Solution

STEP 0: Pre-Calculation Summary
Formula Used
G21 Parameter = -Y21 Parameter/Y22 Parameter
g21 = -Y21/Y22
This formula uses 3 Variables
Variables Used
G21 Parameter - G21 Parameter is Open circuit voltage ratio.
Y21 Parameter - (Measured in Siemens) - Y21 Parameter is forward transfer Admittance.
Y22 Parameter - (Measured in Siemens) - Y22 Parameter is driving point Admittance at port 2.
STEP 1: Convert Input(s) to Base Unit
Y21 Parameter: 1.21 Mho --> 1.21 Siemens (Check conversion ​here)
Y22 Parameter: 1.22 Mho --> 1.22 Siemens (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
g21 = -Y21/Y22 --> -1.21/1.22
Evaluating ... ...
g21 = -0.991803278688525
STEP 3: Convert Result to Output's Unit
-0.991803278688525 --> No Conversion Required
FINAL ANSWER
-0.991803278688525 -0.991803 <-- G21 Parameter
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

16 G-Parameters Calculators

G12 Parameter given Current-1 (G-Parameter)
​ Go G12 Parameter = (Current in Port 1-(G11 Parameter*Voltage Port 1))/Current in Port 2
G11 Parameter given Current-1 (G-Parameter)
​ Go G11 Parameter = (Current in Port 1-(G12 Parameter*Current in Port 2))/Voltage Port 1
Current-1 (G-Parameter)
​ Go Current in Port 1 = (G11 Parameter*Voltage Port 1)+(G12 Parameter*Current in Port 2)
Current-2 given Voltage-2 (G-Parameter)
​ Go Current in Port 2 = (Voltage Port 2-(G21 Parameter*Voltage Port 1))/G22 Parameter
G12 Parameter (G-Parameter)
​ Go G12 Parameter = Current in Port 1/Current in Port 2
Current-1 given G11 Parameter (G-Parameter)
​ Go Current in Port 1 = Voltage Port 1*G11 Parameter
G11 Parameter (G-Parameter)
​ Go G11 Parameter = Current in Port 1/Voltage Port 1
Delta-G given A' Parameter
​ Go Delta-G = (-1)*G12 Parameter*A Inverse Parameter
G21 Parameter (G-Parameter)
​ Go G21 Parameter = Voltage Port 2/Voltage Port 1
G21 Parameter in Terms of Y Parameters
​ Go G21 Parameter = -Y21 Parameter/Y22 Parameter
G21 Parameter in Terms of Z Parameters
​ Go G21 Parameter = Z21 Parameter/Z11 Parameter
G11 Parameter in Terms of T Parameters
​ Go G11 Parameter = C Parameter/A Parameter
G22 Parameter in Terms of Z Parameters
​ Go G22 Parameter = Delta-Z/Z11 Parameter
G11 Parameter in Terms of Y Parameters
​ Go G11 Parameter = Delta-Y/Y22 Parameter
G22 Parameter in Terms of Y Parameters
​ Go G22 Parameter = 1/Y22 Parameter
G21 Parameter in Terms of T Parameters
​ Go G21 Parameter = 1/A Parameter

G21 Parameter in Terms of Y Parameters Formula

G21 Parameter = -Y21 Parameter/Y22 Parameter
g21 = -Y21/Y22

What are G-parameters?

One of a set of four transistor equivalent-circuit parameters; they are the inverse of the h parameters. G21 is defined as the open-circuit voltage ratio of two-port network and also known as inverse hybrid.

How to Calculate G21 Parameter in Terms of Y Parameters?

G21 Parameter in Terms of Y Parameters calculator uses G21 Parameter = -Y21 Parameter/Y22 Parameter to calculate the G21 Parameter, The G21 Parameter in Terms of Y Parameters formula is defined as the open-circuit voltage ratio of two-port network and also known as inverse hybrid. G21 Parameter is denoted by g21 symbol.

How to calculate G21 Parameter in Terms of Y Parameters using this online calculator? To use this online calculator for G21 Parameter in Terms of Y Parameters, enter Y21 Parameter (Y21) & Y22 Parameter (Y22) and hit the calculate button. Here is how the G21 Parameter in Terms of Y Parameters calculation can be explained with given input values -> -0.991803 = -1.21/1.22.

FAQ

What is G21 Parameter in Terms of Y Parameters?
The G21 Parameter in Terms of Y Parameters formula is defined as the open-circuit voltage ratio of two-port network and also known as inverse hybrid and is represented as g21 = -Y21/Y22 or G21 Parameter = -Y21 Parameter/Y22 Parameter. Y21 Parameter is forward transfer Admittance & Y22 Parameter is driving point Admittance at port 2.
How to calculate G21 Parameter in Terms of Y Parameters?
The G21 Parameter in Terms of Y Parameters formula is defined as the open-circuit voltage ratio of two-port network and also known as inverse hybrid is calculated using G21 Parameter = -Y21 Parameter/Y22 Parameter. To calculate G21 Parameter in Terms of Y Parameters, you need Y21 Parameter (Y21) & Y22 Parameter (Y22). With our tool, you need to enter the respective value for Y21 Parameter & Y22 Parameter and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate G21 Parameter?
In this formula, G21 Parameter uses Y21 Parameter & Y22 Parameter. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • G21 Parameter = Voltage Port 2/Voltage Port 1
  • G21 Parameter = Z21 Parameter/Z11 Parameter
  • G21 Parameter = 1/A Parameter
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!