H21 Parameter in Terms of Z Parameters Solution

STEP 0: Pre-Calculation Summary
Formula Used
H21 Parameter = -Z21 Parameter/Z22 Parameter
h21 = -Z21/Z22
This formula uses 3 Variables
Variables Used
H21 Parameter - H21 Parameter is short circuit current gain.
Z21 Parameter - (Measured in Ohm) - Z21 Parameter is forward transfer impedance.
Z22 Parameter - (Measured in Ohm) - Z22 Parameter is driving point impedance at port 2.
STEP 1: Convert Input(s) to Base Unit
Z21 Parameter: 21 Ohm --> 21 Ohm No Conversion Required
Z22 Parameter: 22 Ohm --> 22 Ohm No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
h21 = -Z21/Z22 --> -21/22
Evaluating ... ...
h21 = -0.954545454545455
STEP 3: Convert Result to Output's Unit
-0.954545454545455 --> No Conversion Required
FINAL ANSWER
-0.954545454545455 -0.954545 <-- H21 Parameter
(Calculation completed in 00.004 seconds)

Credits

Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

25 H-parameter Calculators

H22 Parameter given Current-2 (H-Parameter)
Go H22 Parameter = (Current in Port 2-(H21 Parameter*Current in Port 1))/Voltage Port 2
Current-1 given Current-2 (H-Parameter)
Go Current in Port 1 = (Current in Port 2-(H22 Parameter*Voltage Port 2))/H21 Parameter
Current-2 (H-Parameter)
Go Current in Port 2 = (H22 Parameter*Voltage Port 2)+(H21 Parameter*Current in Port 1)
H12 Parameter given Voltage-1 (H-Parameter)
Go H12 Parameter = (Voltage Port 1-(H11 Parameter*Current in Port 1))/Voltage Port 2
Current-1 given Voltage-1 (H-Parameter)
Go Current in Port 1 = (Voltage Port 1-(H12 Parameter*Voltage Port 2))/H11 Parameter
Current-2 given H21 Parameter (H-Parameter)
Go Current in Port 2 = H21 Parameter*Current in Port 1
Current-1 given H21 Parameter (H-Parameter)
Go Current in Port 1 = Current in Port 2/H21 Parameter
H21 Parameter (H-Parameter)
Go H21 Parameter = Current in Port 2/Current in Port 1
Voltage-2 given H22 Parameter (H-Parameter)
Go Voltage Port 2 = Current in Port 2/H22 Parameter
Voltage-1 given H11 Parameter (H-Parameter)
Go Voltage Port 1 = Current in Port 1*H11 Parameter
Current-1 given H11 Parameter (H-Parameter)
Go Current in Port 1 = Voltage Port 1/H11 Parameter
Current-2 given H22 Parameter (H-Parameter)
Go Current in Port 2 = Voltage Port 2*H22 Parameter
H11 Parameter (H-Parameter)
Go H11 Parameter = Voltage Port 1/Current in Port 1
H22 Parameter (H-Parameter)
Go H22 Parameter = Current in Port 2/Voltage Port 2
Voltage-1 given H12 Parameter (H-Parameter)
Go Voltage Port 1 = H12 Parameter*Voltage Port 2
H12 Parameter (H-Parameter)
Go H12 Parameter = Voltage Port 1/Voltage Port 2
H21 Parameter in Terms of Z Parameters
Go H21 Parameter = -Z21 Parameter/Z22 Parameter
H12 Parameter in Terms of Z Parameters
Go H12 Parameter = Z12 Parameter/Z22 Parameter
H21 Parameter in Terms of Y Parameters
Go H21 Parameter = Y21 Parameter/Y11 Parameter
H21 Parameter in Terms of G Parameters
Go H21 Parameter = (-1)*G21 Parameter/Delta-G
H12 Parameter in Terms of G Parameters
Go H12 Parameter = (-1)*G12 Parameter/Delta-G
H11 Parameter in Terms of Z Parameters
Go H11 Parameter = Delta-Z/Z22 Parameter
H22 Parameter in Terms of Y Parameters
Go H22 Parameter = Delta-Y/Y11 Parameter
H22 Parameter in Terms of Z Parameters
Go H22 Parameter = 1/Z22 Parameter
H11 Parameter in Terms of Y Parameters
Go H11 Parameter = 1/Y11 Parameter

H21 Parameter in Terms of Z Parameters Formula

H21 Parameter = -Z21 Parameter/Z22 Parameter
h21 = -Z21/Z22

What is hybrid equivalent model?

The hybrid equivalent model is a transistor amplifier circuit. Such a circuit can be connected in any one of the three configurations called common emitter, common base, or common collector to a voltage source (Vs) and load resistance (RI).

How to Calculate H21 Parameter in Terms of Z Parameters?

H21 Parameter in Terms of Z Parameters calculator uses H21 Parameter = -Z21 Parameter/Z22 Parameter to calculate the H21 Parameter, The H21 Parameter in Terms of Z Parameters formula is defined as the short-circuit condition at port-2 of two-port network and hybrid parameter. H21 Parameter is denoted by h21 symbol.

How to calculate H21 Parameter in Terms of Z Parameters using this online calculator? To use this online calculator for H21 Parameter in Terms of Z Parameters, enter Z21 Parameter (Z21) & Z22 Parameter (Z22) and hit the calculate button. Here is how the H21 Parameter in Terms of Z Parameters calculation can be explained with given input values -> -0.954545 = -21/22.

FAQ

What is H21 Parameter in Terms of Z Parameters?
The H21 Parameter in Terms of Z Parameters formula is defined as the short-circuit condition at port-2 of two-port network and hybrid parameter and is represented as h21 = -Z21/Z22 or H21 Parameter = -Z21 Parameter/Z22 Parameter. Z21 Parameter is forward transfer impedance & Z22 Parameter is driving point impedance at port 2.
How to calculate H21 Parameter in Terms of Z Parameters?
The H21 Parameter in Terms of Z Parameters formula is defined as the short-circuit condition at port-2 of two-port network and hybrid parameter is calculated using H21 Parameter = -Z21 Parameter/Z22 Parameter. To calculate H21 Parameter in Terms of Z Parameters, you need Z21 Parameter (Z21) & Z22 Parameter (Z22). With our tool, you need to enter the respective value for Z21 Parameter & Z22 Parameter and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate H21 Parameter?
In this formula, H21 Parameter uses Z21 Parameter & Z22 Parameter. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • H21 Parameter = Current in Port 2/Current in Port 1
  • H21 Parameter = Y21 Parameter/Y11 Parameter
  • H21 Parameter = (-1)*G21 Parameter/Delta-G
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!