Heat Flux in Fully Developed Boiling State for Higher Pressures Solution

STEP 0: Pre-Calculation Summary
Formula Used
Rate of Heat Transfer = 283.2*Area*((Excess Temperature)^(3))*((Pressure)^(4/3))
qrate = 283.2*A*((ΔTx)^(3))*((pHT)^(4/3))
This formula uses 4 Variables
Variables Used
Rate of Heat Transfer - (Measured in Joule per Second) - Rate of Heat Transfer is defined as the amount of heat transferred per unit time in the material.
Area - (Measured in Square Meter) - The area is the amount of two-dimensional space taken up by an object.
Excess Temperature - (Measured in Kelvin) - Excess Temperature is defined as the temperature difference between heat source and saturation temperature of the fluid.
Pressure - (Measured in Pascal) - Pressure is the force applied perpendicular to the surface of an object per unit area over which that force is distributed.
STEP 1: Convert Input(s) to Base Unit
Area: 5 Square Meter --> 5 Square Meter No Conversion Required
Excess Temperature: 2.25 Degree Celsius --> 2.25 Kelvin (Check conversion here)
Pressure: 3E-08 Megapascal --> 0.03 Pascal (Check conversion here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
qrate = 283.2*A*((ΔTx)^(3))*((pHT)^(4/3)) --> 283.2*5*((2.25)^(3))*((0.03)^(4/3))
Evaluating ... ...
qrate = 150.350824477779
STEP 3: Convert Result to Output's Unit
150.350824477779 Joule per Second -->150.350824477779 Watt (Check conversion here)
FINAL ANSWER
150.350824477779 150.3508 Watt <-- Rate of Heat Transfer
(Calculation completed in 00.004 seconds)

Credits

Created by Ayush gupta
University School of Chemical Technology-USCT (GGSIPU), New Delhi
Ayush gupta has created this Calculator and 300+ more calculators!
Verified by Prerana Bakli
University of Hawaiʻi at Mānoa (UH Manoa), Hawaii, USA
Prerana Bakli has verified this Calculator and 1600+ more calculators!

16 Important Formulas of Condensation Number, Average Heat Transfer Coefficient and Heat Flux Calculators

Average Heat Transfer Coefficient for Condensation Inside Horizontal Tubes for Low Vapor Velocity
Go Average Heat Transfer Coefficient = 0.555*((Density of Liquid Film* (Density of Liquid Film-Density of Vapor)*[g]*Corrected Latent Heat of Vaporization* (Thermal Conductivity of Film Condensate^3))/(Length of Plate*Diameter of Tube* (Saturation Temperature-Plate Surface Temperature)))^(0.25)
Average Heat Transfer Coefficient for Laminar Film Condensation on Outside of Sphere
Go Average Heat Transfer Coefficient = 0.815*((Density of Liquid Film* (Density of Liquid Film-Density of Vapor)*[g]*Latent Heat of Vaporization* (Thermal Conductivity of Film Condensate^3))/(Diameter of Sphere*Viscosity of Film* (Saturation Temperature-Plate Surface Temperature)))^(0.25)
Average Heat Transfer Coefficient for Laminar Film Condensation of Tube
Go Average Heat Transfer Coefficient = 0.725*((Density of Liquid Film* (Density of Liquid Film-Density of Vapor)*[g]*Latent Heat of Vaporization* (Thermal Conductivity of Film Condensate^3))/(Diameter of Tube*Viscosity of Film* (Saturation Temperature-Plate Surface Temperature)))^(0.25)
Average Heat Transfer Coefficient for Vapor Condensing on Plate
Go Average Heat Transfer Coefficient = 0.943*((Density of Liquid Film* (Density of Liquid Film-Density of Vapor)*[g]*Latent Heat of Vaporization* (Thermal Conductivity of Film Condensate^3))/(Length of Plate*Viscosity of Film* (Saturation Temperature-Plate Surface Temperature)))^(0.25)
Average Heat Transfer Coefficient for Film Condensation on Plate for Wavy Laminar Flow
Go Average Heat Transfer Coefficient = 1.13*((Density of Liquid Film* (Density of Liquid Film-Density of Vapor)*[g]*Latent Heat of Vaporization* (Thermal Conductivity of Film Condensate^3))/(Length of Plate*Viscosity of Film* (Saturation Temperature-Plate Surface Temperature)))^(0.25)
Condensation Number given Reynolds Number
Go Condensation Number = ((Constant for Condensation Number)^(4/3))* (((4*sin(Inclination Angle)*((Cross Sectional Area of Flow/Wetted Perimeter)))/(Length of Plate))^(1/3))* ((Reynolds Number of Film)^(-1/3))
Condensation Number
Go Condensation Number = (Average Heat Transfer Coefficient)* ((((Viscosity of Film)^2)/((Thermal Conductivity^3)*(Density of Liquid Film)*(Density of Liquid Film-Density of Vapor)*[g]))^(1/3))
Critical Heat Flux by Zuber
Go Critical Heat Flux = ((0.149*Enthalpy of Vaporization of Liquid*Density of Vapor)* (((Surface Tension*[g])*(Density of Liquid-Density of Vapor))/ (Density of Vapor^2))^(1/4))
Average Heat Transfer Coefficient given Reynolds Number and Properties at Film Temperature
Go Average Heat Transfer Coefficient = (0.026*(Prandtl Number at Film Temperature^(1/3))*(Reynolds Number for Mixing^(0.8))*(Thermal Conductivity at Film Temperature))/Diameter of Tube
Heat Transfer Rate for Condensation of Superheated Vapors
Go Heat Transfer = Average Heat Transfer Coefficient*Area of Plate*(Saturation Temperature for Superheated Vapor-Plate Surface Temperature)
Correlation for Heat Flux proposed by Mostinski
Go Heat Transfer Coefficient For Nucleate Boiling = 0.00341*(Critical Pressure^2.3)*(Excess Temperature in Nucleate Boiling^2.33)*(Reduced Pressure^0.566)
Heat Flux in Fully Developed Boiling State for Higher Pressures
Go Rate of Heat Transfer = 283.2*Area*((Excess Temperature)^(3))*((Pressure)^(4/3))
Heat Flux in Fully Developed Boiling State for Pressure upto 0.7 Megapascal
Go Rate of Heat Transfer = 2.253*Area*((Excess Temperature)^(3.96))
Condensation Number when Turbulence is Encountered in Film
Go Condensation Number = 0.0077*((Reynolds Number of Film)^(0.4))
Condensation Number for Horizontal Cylinder
Go Condensation Number = 1.514*((Reynolds Number of Film)^(-1/3))
Condensation Number for Vertical Plate
Go Condensation Number = 1.47*((Reynolds Number of Film)^(-1/3))

14 Boiling Calculators

Radius of Vapour Bubble in Mechanical Equilibrium in Superheated Liquid
Go Radius of Vapor Bubble = (2*Surface Tension*[R]*(Saturation Temperature^2))/(Pressure of Superheated Liquid*Enthalpy of Vaporization of Liquid*(Temperature of Superheated Liquid-Saturation Temperature))
Critical Heat Flux by Zuber
Go Critical Heat Flux = ((0.149*Enthalpy of Vaporization of Liquid*Density of Vapor)* (((Surface Tension*[g])*(Density of Liquid-Density of Vapor))/ (Density of Vapor^2))^(1/4))
Radiation Heat Transfer Coefficient
Go Radiation Heat Transfer Coefficient = (([Stefan-BoltZ]*Emissivity*(((Plate Surface Temperature)^4)-((Saturation Temperature)^4)))/(Plate Surface Temperature-Saturation Temperature))
Total Heat Transfer Coefficient
Go Total Heat Transfer Coefficient = Heat Transfer Coefficient in Film Boiling Region* ((Heat Transfer Coefficient in Film Boiling Region/Heat Transfer Coefficient)^(1/3))+Radiation Heat Transfer Coefficient
Modified Heat of Vaporization
Go Modified Heat of Vaporization = (Latent Heat of Vaporization+(Specific Heat of Water Vapor)*((Plate Surface Temperature-Saturation Temperature)/2))
Modified Heat Transfer Coefficient under Influence of Pressure
Go Heat Transfer Coefficient at Some Pressure P = (Heat Transfer Coefficient at Atmospheric Pressure)*((System Pressure/Standard Atmospheric Pressure)^(0.4))
Correlation for Heat Flux proposed by Mostinski
Go Heat Transfer Coefficient For Nucleate Boiling = 0.00341*(Critical Pressure^2.3)*(Excess Temperature in Nucleate Boiling^2.33)*(Reduced Pressure^0.566)
Heat Transfer Coefficient for Forced Convection Local Boiling Inside Vertical Tubes
Go Heat Transfer Coefficient for Forced Convection = (2.54*((Excess Temperature)^3)*exp((System Pressure in Vertical Tubes)/1.551))
Heat Flux in Fully Developed Boiling State for Higher Pressures
Go Rate of Heat Transfer = 283.2*Area*((Excess Temperature)^(3))*((Pressure)^(4/3))
Heat Transfer Coefficient given Biot Number
Go Heat Transfer Coefficient = (Biot Number*Thermal Conductivity)/Thickness of Wall
Saturated Temperature given Excess Temperature
Go Saturation Temperature = Surface Temperature-Excess Temperature in Heat Transfer
Surface Temperature given Excess Temperature
Go Surface Temperature = Saturation Temperature+Excess Temperature in Heat Transfer
Excess Temperature in Boiling
Go Excess Temperature in Heat Transfer = Surface Temperature-Saturation Temperature
Heat Flux in Fully Developed Boiling State for Pressure upto 0.7 Megapascal
Go Rate of Heat Transfer = 2.253*Area*((Excess Temperature)^(3.96))

Heat Flux in Fully Developed Boiling State for Higher Pressures Formula

Rate of Heat Transfer = 283.2*Area*((Excess Temperature)^(3))*((Pressure)^(4/3))
qrate = 283.2*A*((ΔTx)^(3))*((pHT)^(4/3))

What is Heat Transfer?

Heat transfer is a discipline of thermal engineering that concerns the generation, use, conversion, and exchange of thermal energy between physical systems. Heat transfer is classified into various mechanisms, such as thermal conduction, thermal convection, thermal radiation, and transfer of energy by phase changes.

Define Thermal Conductivity & Factors affecting it?

Thermal conductivity is defined as the ability of a substance to conduct heat. Factors Affecting The Thermal Conductivity are: Moisture, Density of material, Pressure, Temperature & Structure of material.

How to Calculate Heat Flux in Fully Developed Boiling State for Higher Pressures?

Heat Flux in Fully Developed Boiling State for Higher Pressures calculator uses Rate of Heat Transfer = 283.2*Area*((Excess Temperature)^(3))*((Pressure)^(4/3)) to calculate the Rate of Heat Transfer, The Heat Flux in Fully Developed Boiling State For Higher Pressures formula is a function of area, excess temperature and pressure for 0.7< p < 14 MPa. Rate of Heat Transfer is denoted by qrate symbol.

How to calculate Heat Flux in Fully Developed Boiling State for Higher Pressures using this online calculator? To use this online calculator for Heat Flux in Fully Developed Boiling State for Higher Pressures, enter Area (A), Excess Temperature (ΔTx) & Pressure (pHT) and hit the calculate button. Here is how the Heat Flux in Fully Developed Boiling State for Higher Pressures calculation can be explained with given input values -> 150.3508 = 283.2*5*((2.25)^(3))*((0.03)^(4/3)).

FAQ

What is Heat Flux in Fully Developed Boiling State for Higher Pressures?
The Heat Flux in Fully Developed Boiling State For Higher Pressures formula is a function of area, excess temperature and pressure for 0.7< p < 14 MPa and is represented as qrate = 283.2*A*((ΔTx)^(3))*((pHT)^(4/3)) or Rate of Heat Transfer = 283.2*Area*((Excess Temperature)^(3))*((Pressure)^(4/3)). The area is the amount of two-dimensional space taken up by an object, Excess Temperature is defined as the temperature difference between heat source and saturation temperature of the fluid & Pressure is the force applied perpendicular to the surface of an object per unit area over which that force is distributed.
How to calculate Heat Flux in Fully Developed Boiling State for Higher Pressures?
The Heat Flux in Fully Developed Boiling State For Higher Pressures formula is a function of area, excess temperature and pressure for 0.7< p < 14 MPa is calculated using Rate of Heat Transfer = 283.2*Area*((Excess Temperature)^(3))*((Pressure)^(4/3)). To calculate Heat Flux in Fully Developed Boiling State for Higher Pressures, you need Area (A), Excess Temperature (ΔTx) & Pressure (pHT). With our tool, you need to enter the respective value for Area, Excess Temperature & Pressure and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Rate of Heat Transfer?
In this formula, Rate of Heat Transfer uses Area, Excess Temperature & Pressure. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Rate of Heat Transfer = 2.253*Area*((Excess Temperature)^(3.96))
  • Rate of Heat Transfer = 2.253*Area*((Excess Temperature)^(3.96))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!