Horizontal Distance from Face of Wall to Main Steel Solution

STEP 0: Pre-Calculation Summary
Formula Used
Horizontal Distance = Normal Shear Unit Stress/(Thickness of Counterfort*Counterfort Shear Unit Stress)
d = Vo/(tc*vc)
This formula uses 4 Variables
Variables Used
Horizontal Distance - (Measured in Meter) - Horizontal Distance is the distance from face of wall to main steel.
Normal Shear Unit Stress - (Measured in Pascal) - Normal Shear Unit Stress is the shear stress acting perpendicularly.
Thickness of Counterfort - (Measured in Meter) - Thickness of Counterfort is the thickness of a buttress built against or integral with a wall (as a retaining wall or dam) but on the back or thrust-receiving side.
Counterfort Shear Unit Stress - (Measured in Pascal) - Counterfort Shear Unit Stress is the unit stress acting on a horizontal section.
STEP 1: Convert Input(s) to Base Unit
Normal Shear Unit Stress: 8 Megapascal --> 8000000 Pascal (Check conversion ​here)
Thickness of Counterfort: 5.1 Millimeter --> 0.0051 Meter (Check conversion ​here)
Counterfort Shear Unit Stress: 3.2 Megapascal --> 3200000 Pascal (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
d = Vo/(tc*vc) --> 8000000/(0.0051*3200000)
Evaluating ... ...
d = 490.196078431372
STEP 3: Convert Result to Output's Unit
490.196078431372 Meter --> No Conversion Required
FINAL ANSWER
490.196078431372 490.1961 Meter <-- Horizontal Distance
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Rachana B V
The National Institute of Engineering (NIE), Mysuru
Rachana B V has created this Calculator and 25+ more calculators!
Verifier Image
Verified by Ayush Singh
Gautam Buddha University (GBU), Greater Noida
Ayush Singh has verified this Calculator and 100+ more calculators!

5 Cantilever and Counterfort Retaining Walls Calculators

Shear Force on Section for Vertical Wall Face
​ Go Shear Force on Section = Shear on Section 1+(Bending Moment/Horizontal Distance)*tan(Angle between Earth and Wall)
Thickness of Counterfort Shear Unit Stress on Horizontal Section
​ Go Thickness of Counterfort = Normal Shear Unit Stress/(Counterfort Shear Unit Stress*Horizontal Distance)
Counterfort Shear Unit Stress on Horizontal Section
​ Go Counterfort Shear Unit Stress = Normal Shear Unit Stress/(Thickness of Counterfort*Horizontal Distance)
Horizontal Distance from Face of Wall to Main Steel
​ Go Horizontal Distance = Normal Shear Unit Stress/(Thickness of Counterfort*Counterfort Shear Unit Stress)
Normal Shear Unit Stress on Horizontal Section
​ Go Normal Shear Unit Stress = (Counterfort Shear Unit Stress*Thickness of Counterfort*Horizontal Distance)

Horizontal Distance from Face of Wall to Main Steel Formula

Horizontal Distance = Normal Shear Unit Stress/(Thickness of Counterfort*Counterfort Shear Unit Stress)
d = Vo/(tc*vc)

What is a Counterfort?

It is a buttress built against or integral with a wall (as a retaining wall or dam) but on the back or thrust-receiving side.

How to Calculate Horizontal Distance from Face of Wall to Main Steel?

Horizontal Distance from Face of Wall to Main Steel calculator uses Horizontal Distance = Normal Shear Unit Stress/(Thickness of Counterfort*Counterfort Shear Unit Stress) to calculate the Horizontal Distance, The Horizontal Distance from Face of Wall to Main Steel formula is defined as the main steel refers to the lateral span to the primary structural steel. Horizontal Distance is denoted by d symbol.

How to calculate Horizontal Distance from Face of Wall to Main Steel using this online calculator? To use this online calculator for Horizontal Distance from Face of Wall to Main Steel, enter Normal Shear Unit Stress (Vo), Thickness of Counterfort (tc) & Counterfort Shear Unit Stress (vc) and hit the calculate button. Here is how the Horizontal Distance from Face of Wall to Main Steel calculation can be explained with given input values -> 490.1961 = 8000000/(0.0051*3200000).

FAQ

What is Horizontal Distance from Face of Wall to Main Steel?
The Horizontal Distance from Face of Wall to Main Steel formula is defined as the main steel refers to the lateral span to the primary structural steel and is represented as d = Vo/(tc*vc) or Horizontal Distance = Normal Shear Unit Stress/(Thickness of Counterfort*Counterfort Shear Unit Stress). Normal Shear Unit Stress is the shear stress acting perpendicularly, Thickness of Counterfort is the thickness of a buttress built against or integral with a wall (as a retaining wall or dam) but on the back or thrust-receiving side & Counterfort Shear Unit Stress is the unit stress acting on a horizontal section.
How to calculate Horizontal Distance from Face of Wall to Main Steel?
The Horizontal Distance from Face of Wall to Main Steel formula is defined as the main steel refers to the lateral span to the primary structural steel is calculated using Horizontal Distance = Normal Shear Unit Stress/(Thickness of Counterfort*Counterfort Shear Unit Stress). To calculate Horizontal Distance from Face of Wall to Main Steel, you need Normal Shear Unit Stress (Vo), Thickness of Counterfort (tc) & Counterfort Shear Unit Stress (vc). With our tool, you need to enter the respective value for Normal Shear Unit Stress, Thickness of Counterfort & Counterfort Shear Unit Stress and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.