Hydraulic Torque Convertor - Power Output Solution

STEP 0: Pre-Calculation Summary
Formula Used
Output power of hydraulic torque converter = Torque transmitted to Turbine Shaft*Angular Velocity of Turbine
Phc = Ts*ωt
This formula uses 3 Variables
Variables Used
Output power of hydraulic torque converter - (Measured in Watt) - Output power of hydraulic torque converter is the power due to the torque transmitted to the turbine shaft of an hydraulic torque converter.
Torque transmitted to Turbine Shaft - (Measured in Newton Meter) - Torque transmitted to turbine shaft is defined as the sum of torque of pump impeller and variation of torque caused by fixed guide vanes.
Angular Velocity of Turbine - (Measured in Radian per Second) - Angular velocity of turbine or driven shaft is the speed at which an hydraulic turbine or actually a driven shaft is rotating.
STEP 1: Convert Input(s) to Base Unit
Torque transmitted to Turbine Shaft: 16.55 Newton Meter --> 16.55 Newton Meter No Conversion Required
Angular Velocity of Turbine: 14 Radian per Second --> 14 Radian per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Phc = Tst --> 16.55*14
Evaluating ... ...
Phc = 231.7
STEP 3: Convert Result to Output's Unit
231.7 Watt --> No Conversion Required
FINAL ANSWER
231.7 Watt <-- Output power of hydraulic torque converter
(Calculation completed in 00.004 seconds)

Credits

Created by Sagar S Kulkarni
Dayananda Sagar College of Engineering (DSCE), Bengaluru
Sagar S Kulkarni has created this Calculator and 200+ more calculators!
Verified by Chilvera Bhanu Teja
Institute of Aeronautical Engineering (IARE), Hyderabad
Chilvera Bhanu Teja has verified this Calculator and 200+ more calculators!

4 Hydraulic Torque Converter Calculators

Efficiency of torque convertor
Go Efficiency of Hydraulic Torque Converter = (Angular Velocity of Turbine/Angular Velocity of Pump)*(1+(Variation of Torque/Torque of Pump Impeller))
Hydraulic Torque Convertor - Power Output
Go Output power of hydraulic torque converter = Torque transmitted to Turbine Shaft*Angular Velocity of Turbine
Hydraulic Torque Convertor - Power Input
Go Input power of hydraulic torque converter = Torque of Pump Impeller*Angular Velocity of Pump
Torque transmitted to turbine shaft of torque converter
Go Torque transmitted to Turbine Shaft = Torque of Pump Impeller+Variation of Torque

Hydraulic Torque Convertor - Power Output Formula

Output power of hydraulic torque converter = Torque transmitted to Turbine Shaft*Angular Velocity of Turbine
Phc = Ts*ωt

What is a hydraulic torque converter?

Hydraulic torque converter is a device used for transmitting increased or decreased power
from one shaft to another.

How to Calculate Hydraulic Torque Convertor - Power Output?

Hydraulic Torque Convertor - Power Output calculator uses Output power of hydraulic torque converter = Torque transmitted to Turbine Shaft*Angular Velocity of Turbine to calculate the Output power of hydraulic torque converter, The Hydraulic Torque Convertor - Power Output formula is defined as the product of torque transmitted to turbine shaft and the angular velocity of turbine. Output power of hydraulic torque converter is denoted by Phc symbol.

How to calculate Hydraulic Torque Convertor - Power Output using this online calculator? To use this online calculator for Hydraulic Torque Convertor - Power Output, enter Torque transmitted to Turbine Shaft (Ts) & Angular Velocity of Turbine t) and hit the calculate button. Here is how the Hydraulic Torque Convertor - Power Output calculation can be explained with given input values -> 231.7 = 16.55*14.

FAQ

What is Hydraulic Torque Convertor - Power Output?
The Hydraulic Torque Convertor - Power Output formula is defined as the product of torque transmitted to turbine shaft and the angular velocity of turbine and is represented as Phc = Tst or Output power of hydraulic torque converter = Torque transmitted to Turbine Shaft*Angular Velocity of Turbine. Torque transmitted to turbine shaft is defined as the sum of torque of pump impeller and variation of torque caused by fixed guide vanes & Angular velocity of turbine or driven shaft is the speed at which an hydraulic turbine or actually a driven shaft is rotating.
How to calculate Hydraulic Torque Convertor - Power Output?
The Hydraulic Torque Convertor - Power Output formula is defined as the product of torque transmitted to turbine shaft and the angular velocity of turbine is calculated using Output power of hydraulic torque converter = Torque transmitted to Turbine Shaft*Angular Velocity of Turbine. To calculate Hydraulic Torque Convertor - Power Output, you need Torque transmitted to Turbine Shaft (Ts) & Angular Velocity of Turbine t). With our tool, you need to enter the respective value for Torque transmitted to Turbine Shaft & Angular Velocity of Turbine and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!