In-Phase Potentiometer Reading Solution

STEP 0: Pre-Calculation Summary
Formula Used
In-Phase Potentiometer Reading Op = Loss Component of Current in Primary Winding*Resistance
Piop = Ic*R
This formula uses 3 Variables
Variables Used
In-Phase Potentiometer Reading Op - (Measured in Volt) - In-Phase Potentiometer Reading Op is defined as a simple knob that provides a variable resistance, which we can read into the Arduino board as an analog value.
Loss Component of Current in Primary Winding - (Measured in Ampere) - Loss Component of Current in Primary Winding is denoted by Ic symbol.
Resistance - (Measured in Ohm) - Resistance is a measure of the opposition to current flow in an electrical circuit. Its S.I unit is ohm.
STEP 1: Convert Input(s) to Base Unit
Loss Component of Current in Primary Winding: 0.682927 Ampere --> 0.682927 Ampere No Conversion Required
Resistance: 10.25 Ohm --> 10.25 Ohm No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Piop = Ic*R --> 0.682927*10.25
Evaluating ... ...
Piop = 7.00000175
STEP 3: Convert Result to Output's Unit
7.00000175 Volt --> No Conversion Required
FINAL ANSWER
7.00000175 7.000002 Volt <-- In-Phase Potentiometer Reading Op
(Calculation completed in 00.004 seconds)

Credits

Created by Shobhit Dimri
Bipin Tripathi Kumaon Institute of Technology (BTKIT), Dwarahat
Shobhit Dimri has created this Calculator and 900+ more calculators!
Verified by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has verified this Calculator and 1900+ more calculators!

9 AC Circuits Calculators

Resistance of Coil in Transfer Type Potentiometer
Go Resistance = (Output resistance*Voltage(coil)/Voltage (shunt))*cos(Phase Angle (coil)-Phase angle (shunt))
Effective Resistance in Coordinate Type Potentiometer
Go Output resistance = Sensitivity*Voltage(coil)/Voltage (shunt)
In-Phase Potentiometer Reading
Go In-Phase Potentiometer Reading Op = Loss Component of Current in Primary Winding*Resistance
Voltage Magnitude of AC Potentiometer
Go Voltage (total) = sqrt((Voltage 1^2)+(Voltage 2^2))
Quadrature Potentiometer Reading
Go Quadrature Potentiometer Reading = Magnetising Component Of Current*Resistance
Full-Scale Voltage Reading
Go Full-scale Voltage Reading = Current at Full-Scale Reading*Resistance of Meter
AC Potentiometer Phase Angle
Go Phase Angle = atan(Voltage 2/Voltage 1)
Potentiometer Voltage
Go Potentiometer Voltage Op = Line Voltage/Voltage Division Ratio
Voltage Output of Volt Ratio Box in Coordinate Type Potentiometer
Go Output Voltage = Input Voltage/1.5

In-Phase Potentiometer Reading Formula

In-Phase Potentiometer Reading Op = Loss Component of Current in Primary Winding*Resistance
Piop = Ic*R

What are the advantages of AC Potentiometer?

AC Potentiometer works on the method of zero deflection so that the possibility of error is extremely small. It is a highly sensitive device, therefore it can measure small EMFs.

How to Calculate In-Phase Potentiometer Reading?

In-Phase Potentiometer Reading calculator uses In-Phase Potentiometer Reading Op = Loss Component of Current in Primary Winding*Resistance to calculate the In-Phase Potentiometer Reading Op, The In-Phase Potentiometer Reading is the product of loss component of the current in the primary winding and the standard resistance in an AC Potentiometer. In-Phase Potentiometer Reading Op is denoted by Piop symbol.

How to calculate In-Phase Potentiometer Reading using this online calculator? To use this online calculator for In-Phase Potentiometer Reading, enter Loss Component of Current in Primary Winding (Ic) & Resistance (R) and hit the calculate button. Here is how the In-Phase Potentiometer Reading calculation can be explained with given input values -> 7.000002 = 0.682927*10.25.

FAQ

What is In-Phase Potentiometer Reading?
The In-Phase Potentiometer Reading is the product of loss component of the current in the primary winding and the standard resistance in an AC Potentiometer and is represented as Piop = Ic*R or In-Phase Potentiometer Reading Op = Loss Component of Current in Primary Winding*Resistance. Loss Component of Current in Primary Winding is denoted by Ic symbol & Resistance is a measure of the opposition to current flow in an electrical circuit. Its S.I unit is ohm.
How to calculate In-Phase Potentiometer Reading?
The In-Phase Potentiometer Reading is the product of loss component of the current in the primary winding and the standard resistance in an AC Potentiometer is calculated using In-Phase Potentiometer Reading Op = Loss Component of Current in Primary Winding*Resistance. To calculate In-Phase Potentiometer Reading, you need Loss Component of Current in Primary Winding (Ic) & Resistance (R). With our tool, you need to enter the respective value for Loss Component of Current in Primary Winding & Resistance and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!