Machine Construction Constant using Speed of Shunt DC Motor Solution

STEP 0: Pre-Calculation Summary
Formula Used
Constant of Machine Construction = (Terminal Voltage-Armature Current*Armature Resistance)/(Motor Speed*Magnetic Flux)
Kf = (Vt-Ia*Ra)/(N*Φ)
This formula uses 6 Variables
Variables Used
Constant of Machine Construction - Constant of Machine construction is a constant term which is calculated separately to a make calculation less complex.
Terminal Voltage - (Measured in Volt) - Terminal Voltage refers to the voltage measured at the terminals of an electrical device, such as a battery, generator, or electric motor.
Armature Current - (Measured in Ampere) - Armature Current DC motor is defined as the armature current developed in an electrical dc motor due to the rotation of rotor.
Armature Resistance - (Measured in Ohm) - The Armature Resistance is the ohmic resistance of the copper winding wires plus the brush resistance in an electrical dc motor.
Motor Speed - (Measured in Radian per Second) - Motor Speed is the speed of the rotor(motor). Motor speed refers to the rate at which a motor rotates or operates. It is a measure of how fast the motor's output shaft or rotor spins.
Magnetic Flux - (Measured in Weber) - Magnetic flux (Φ) is the number of magnetic field lines passing through the magnetic core of an electrical dc motor.
STEP 1: Convert Input(s) to Base Unit
Terminal Voltage: 75 Volt --> 75 Volt No Conversion Required
Armature Current: 3.7 Ampere --> 3.7 Ampere No Conversion Required
Armature Resistance: 2.16 Ohm --> 2.16 Ohm No Conversion Required
Motor Speed: 2579.98 Revolution per Minute --> 270.174873799862 Radian per Second (Check conversion here)
Magnetic Flux: 0.114 Weber --> 0.114 Weber No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Kf = (Vt-Ia*Ra)/(N*Φ) --> (75-3.7*2.16)/(270.174873799862*0.114)
Evaluating ... ...
Kf = 2.17558896361187
STEP 3: Convert Result to Output's Unit
2.17558896361187 --> No Conversion Required
FINAL ANSWER
2.17558896361187 2.175589 <-- Constant of Machine Construction
(Calculation completed in 00.004 seconds)

Credits

Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

7 Mechanical Specifications Calculators

Machine Construction Constant using Speed of Shunt DC Motor
Go Constant of Machine Construction = (Terminal Voltage-Armature Current*Armature Resistance)/(Motor Speed*Magnetic Flux)
Machine Construction Constant of Shunt DC Motor
Go Constant of Machine Construction = (60*Number of Parallel Paths)/(Number of Poles*Number of Conductors)
Number of Armature Conductors of DC Shunt Motor using K
Go Number of Conductors = (60*Number of Parallel Paths)/(Machine Constant*Number of Poles)
Number of Poles of Shunt DC Motor
Go Number of Poles = (60*Number of Parallel Paths)/(Machine Constant*Number of Conductors)
Number of Parallel Paths of Shunt DC Motor
Go Number of Parallel Paths = (Machine Constant*Number of Conductors*Number of Poles)/60
Machine Construction Constant of DC Shunt Motor given Angular Speed
Go Constant of Machine Construction = Back EMF/(Magnetic Flux*Angular Speed)
Machine Constant of DC Shunt Motor given Torque
Go Machine Constant = Torque/(Magnetic Flux*Armature Current)

Machine Construction Constant using Speed of Shunt DC Motor Formula

Constant of Machine Construction = (Terminal Voltage-Armature Current*Armature Resistance)/(Motor Speed*Magnetic Flux)
Kf = (Vt-Ia*Ra)/(N*Φ)

What is a DC shunt motor?

A DC shunt motor is a type of self-excited DC motor, and it is also known as a shunt wound DC motor. The field windings in this motor can be connected in parallel to the armature winding.

How to Calculate Machine Construction Constant using Speed of Shunt DC Motor?

Machine Construction Constant using Speed of Shunt DC Motor calculator uses Constant of Machine Construction = (Terminal Voltage-Armature Current*Armature Resistance)/(Motor Speed*Magnetic Flux) to calculate the Constant of Machine Construction, The Machine Construction Constant using Speed of Shunt DC Motor formula is defined as a constant based on machine construction that is required to find all the basic quality of the machine. Constant of Machine Construction is denoted by Kf symbol.

How to calculate Machine Construction Constant using Speed of Shunt DC Motor using this online calculator? To use this online calculator for Machine Construction Constant using Speed of Shunt DC Motor, enter Terminal Voltage (Vt), Armature Current (Ia), Armature Resistance (Ra), Motor Speed (N) & Magnetic Flux (Φ) and hit the calculate button. Here is how the Machine Construction Constant using Speed of Shunt DC Motor calculation can be explained with given input values -> 7.532743 = (75-3.7*2.16)/(270.174873799862*0.114).

FAQ

What is Machine Construction Constant using Speed of Shunt DC Motor?
The Machine Construction Constant using Speed of Shunt DC Motor formula is defined as a constant based on machine construction that is required to find all the basic quality of the machine and is represented as Kf = (Vt-Ia*Ra)/(N*Φ) or Constant of Machine Construction = (Terminal Voltage-Armature Current*Armature Resistance)/(Motor Speed*Magnetic Flux). Terminal Voltage refers to the voltage measured at the terminals of an electrical device, such as a battery, generator, or electric motor, Armature Current DC motor is defined as the armature current developed in an electrical dc motor due to the rotation of rotor, The Armature Resistance is the ohmic resistance of the copper winding wires plus the brush resistance in an electrical dc motor, Motor Speed is the speed of the rotor(motor). Motor speed refers to the rate at which a motor rotates or operates. It is a measure of how fast the motor's output shaft or rotor spins & Magnetic flux (Φ) is the number of magnetic field lines passing through the magnetic core of an electrical dc motor.
How to calculate Machine Construction Constant using Speed of Shunt DC Motor?
The Machine Construction Constant using Speed of Shunt DC Motor formula is defined as a constant based on machine construction that is required to find all the basic quality of the machine is calculated using Constant of Machine Construction = (Terminal Voltage-Armature Current*Armature Resistance)/(Motor Speed*Magnetic Flux). To calculate Machine Construction Constant using Speed of Shunt DC Motor, you need Terminal Voltage (Vt), Armature Current (Ia), Armature Resistance (Ra), Motor Speed (N) & Magnetic Flux (Φ). With our tool, you need to enter the respective value for Terminal Voltage, Armature Current, Armature Resistance, Motor Speed & Magnetic Flux and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Constant of Machine Construction?
In this formula, Constant of Machine Construction uses Terminal Voltage, Armature Current, Armature Resistance, Motor Speed & Magnetic Flux. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Constant of Machine Construction = (60*Number of Parallel Paths)/(Number of Poles*Number of Conductors)
  • Constant of Machine Construction = Back EMF/(Magnetic Flux*Angular Speed)