Credits

Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1000+ more calculators!
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1000+ more calculators!

Length Of Wire Using Area Of X-section(2-phase 4-wire OS) Solution

STEP 0: Pre-Calculation Summary
Formula Used
length = 2*Area Of X-Section*(Maximum Voltage^2)*Line Losses*((cos(Theta))^2)/(Resistivity*(Power Transmitted^2))
l = 2*a*(Vm^2)*W*((cos(ϑ))^2)/(ρ*(P^2))
This formula uses 1 Functions, 6 Variables
Functions Used
cos - Trigonometric cosine function, cos(Angle)
Variables Used
Area Of X-Section - Area Of X-Section is defined as the cross-sectional area simply as the square of the wire's diameter in mils and calls that our area in units of “circular mils.” (Measured in Square Meter)
Maximum Voltage - Maximum Voltage the highest voltage rating for electrical devices (Measured in Volt)
Line Losses - Line Losses is defined as the losses that are produced in the line. (Measured in Watt)
Theta - Theta is an angle that can be defined as the figure formed by two rays meeting at a common endpoint. (Measured in Degree)
Resistivity - Resistivity is the measure of how strongly a material opposes the flow of current through them. (Measured in Ohm Meter)
Power Transmitted - The Power Transmitted Value through a shaft. (Measured in Kilowatt)
STEP 1: Convert Input(s) to Base Unit
Area Of X-Section: 5 Square Meter --> 5 Square Meter No Conversion Required
Maximum Voltage: 60 Volt --> 60 Volt No Conversion Required
Line Losses: 0.6 Watt --> 0.6 Watt No Conversion Required
Theta: 30 Degree --> 0.5235987755982 Radian (Check conversion here)
Resistivity: 1.7E-05 Ohm Meter --> 1.7E-05 Ohm Meter No Conversion Required
Power Transmitted: 10 Kilowatt --> 10000 Watt (Check conversion here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
l = 2*a*(Vm^2)*W*((cos(ϑ))^2)/(ρ*(P^2)) --> 2*5*(60^2)*0.6*((cos(0.5235987755982))^2)/(1.7E-05*(10000^2))
Evaluating ... ...
l = 9.52941176470588
STEP 3: Convert Result to Output's Unit
9.52941176470588 Meter --> No Conversion Required
FINAL ANSWER
9.52941176470588 Meter <-- Length
(Calculation completed in 00.016 seconds)

9 Area Of X-Section Calculators

Power Transmitted Using Area Of X-Section(2-phase 4-wire OS)
power_transmitted = sqrt((2*Area Of X-Section*(Maximum Voltage^2)*Line Losses*((cos(Theta))^2))/(Resistivity*Length)) Go
Maximum Voltage Using Area Of X-section(2-phase 4-wire OS)
maximum_voltage = sqrt((Length*Resistivity*(Power Transmitted^2))/(2*Area Of X-Section*Line Losses*((cos(Theta))^2))) Go
RMS Voltage Using Area Of X-Section(2-phase 4-wire OS)
rms_voltage = sqrt((Length*Resistivity*(Power Transmitted^2))/(Area Of X-Section*Line Losses*((cos(Theta))^2))) Go
Power Factor Using Area Of X-section(2-phase 4-wire OS)
power_factor = sqrt((Power Transmitted^2)*Resistivity*Length/(2*Area Of X-Section*Line Losses*(Maximum Voltage^2))) Go
Line Losses Using Area Of X-Section(2-phase 4-wire OS)
line_losses = (Length*Resistivity*(Power Transmitted^2))/(2*Area Of X-Section*(Maximum Voltage^2)*((cos(Theta))^2)) Go
Length Of Wire Using Area Of X-section(2-phase 4-wire OS)
length = 2*Area Of X-Section*(Maximum Voltage^2)*Line Losses*((cos(Theta))^2)/(Resistivity*(Power Transmitted^2)) Go
Resistivity Using Area Of X-Section(2-phase 4-wire OS)
resistivity = 2*Area Of X-Section*(Maximum Voltage^2)*Line Losses*((cos(Theta))^2)/(Length*(Power Transmitted^2)) Go
Load Current Using Area Of X-section(2-phase 4-wire OS)
load_current = sqrt(Line Losses*Area Of X-Section/((32)*Resistivity*Length)) Go
Volume Of Conductor Material Using Area Of X-Section(2-phase 4-wire OS)
volume_of_conductor_material = (4)*Area Of X-Section*Length Go

Length Of Wire Using Area Of X-section(2-phase 4-wire OS) Formula

length = 2*Area Of X-Section*(Maximum Voltage^2)*Line Losses*((cos(Theta))^2)/(Resistivity*(Power Transmitted^2))
l = 2*a*(Vm^2)*W*((cos(ϑ))^2)/(ρ*(P^2))

What is the value of maximum voltage and volume of conductor material in 2-phase 4-wire system?

The volume of conductor material required in this system is 1/2cos2θ times that of 2-wire d.c.system with the one conductor earthed. The maximum voltage between conductors is 2vm so that r.m.s. value of voltage between them is √2vm.

How to Calculate Length Of Wire Using Area Of X-section(2-phase 4-wire OS)?

Length Of Wire Using Area Of X-section(2-phase 4-wire OS) calculator uses length = 2*Area Of X-Section*(Maximum Voltage^2)*Line Losses*((cos(Theta))^2)/(Resistivity*(Power Transmitted^2)) to calculate the Length, The Length Of Wire Using Area Of X-section(2-phase 4-wire OS) formula is defined as the total length of the wire that used in the two-phase four-wire system. Length and is denoted by l symbol.

How to calculate Length Of Wire Using Area Of X-section(2-phase 4-wire OS) using this online calculator? To use this online calculator for Length Of Wire Using Area Of X-section(2-phase 4-wire OS), enter Area Of X-Section (a), Maximum Voltage (Vm), Line Losses (W), Theta (ϑ), Resistivity (ρ) and Power Transmitted (P) and hit the calculate button. Here is how the Length Of Wire Using Area Of X-section(2-phase 4-wire OS) calculation can be explained with given input values -> 9.529412 = 2*5*(60^2)*0.6*((cos(0.5235987755982))^2)/(1.7E-05*(10000^2)).

FAQ

What is Length Of Wire Using Area Of X-section(2-phase 4-wire OS)?
The Length Of Wire Using Area Of X-section(2-phase 4-wire OS) formula is defined as the total length of the wire that used in the two-phase four-wire system and is represented as l = 2*a*(Vm^2)*W*((cos(ϑ))^2)/(ρ*(P^2)) or length = 2*Area Of X-Section*(Maximum Voltage^2)*Line Losses*((cos(Theta))^2)/(Resistivity*(Power Transmitted^2)). Area Of X-Section is defined as the cross-sectional area simply as the square of the wire's diameter in mils and calls that our area in units of “circular mils.”, Maximum Voltage the highest voltage rating for electrical devices, Line Losses is defined as the losses that are produced in the line, Theta is an angle that can be defined as the figure formed by two rays meeting at a common endpoint, Resistivity is the measure of how strongly a material opposes the flow of current through them and The Power Transmitted Value through a shaft.
How to calculate Length Of Wire Using Area Of X-section(2-phase 4-wire OS)?
The Length Of Wire Using Area Of X-section(2-phase 4-wire OS) formula is defined as the total length of the wire that used in the two-phase four-wire system is calculated using length = 2*Area Of X-Section*(Maximum Voltage^2)*Line Losses*((cos(Theta))^2)/(Resistivity*(Power Transmitted^2)). To calculate Length Of Wire Using Area Of X-section(2-phase 4-wire OS), you need Area Of X-Section (a), Maximum Voltage (Vm), Line Losses (W), Theta (ϑ), Resistivity (ρ) and Power Transmitted (P). With our tool, you need to enter the respective value for Area Of X-Section, Maximum Voltage, Line Losses, Theta, Resistivity and Power Transmitted and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Length?
In this formula, Length uses Area Of X-Section, Maximum Voltage, Line Losses, Theta, Resistivity and Power Transmitted. We can use 9 other way(s) to calculate the same, which is/are as follows -
  • line_losses = (Length*Resistivity*(Power Transmitted^2))/(2*Area Of X-Section*(Maximum Voltage^2)*((cos(Theta))^2))
  • maximum_voltage = sqrt((Length*Resistivity*(Power Transmitted^2))/(2*Area Of X-Section*Line Losses*((cos(Theta))^2)))
  • power_factor = sqrt((Power Transmitted^2)*Resistivity*Length/(2*Area Of X-Section*Line Losses*(Maximum Voltage^2)))
  • power_transmitted = sqrt((2*Area Of X-Section*(Maximum Voltage^2)*Line Losses*((cos(Theta))^2))/(Resistivity*Length))
  • resistivity = 2*Area Of X-Section*(Maximum Voltage^2)*Line Losses*((cos(Theta))^2)/(Length*(Power Transmitted^2))
  • length = 2*Area Of X-Section*(Maximum Voltage^2)*Line Losses*((cos(Theta))^2)/(Resistivity*(Power Transmitted^2))
  • volume_of_conductor_material = (4)*Area Of X-Section*Length
  • load_current = sqrt(Line Losses*Area Of X-Section/((32)*Resistivity*Length))
  • rms_voltage = sqrt((Length*Resistivity*(Power Transmitted^2))/(Area Of X-Section*Line Losses*((cos(Theta))^2)))
Where is the Length Of Wire Using Area Of X-section(2-phase 4-wire OS) calculator used?
Among many, Length Of Wire Using Area Of X-section(2-phase 4-wire OS) calculator is widely used in real life applications like {FormulaUses}. Here are few more real life examples -
{FormulaExamplesList}
Share Image
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!