Length using Volume of Conductor Material (2 Phase 4 Wire US) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Length of Underground AC Wire = Volume Of Conductor/(2*Area of Underground AC Wire)
L = V/(2*A)
This formula uses 3 Variables
Variables Used
Length of Underground AC Wire - (Measured in Meter) - Length of Underground AC Wire is the total length of the wire from one end to other end.
Volume Of Conductor - (Measured in Cubic Meter) - Volume Of Conductor the 3-dimensional space enclosed by a conductor material.
Area of Underground AC Wire - (Measured in Square Meter) - Area of Underground AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
STEP 1: Convert Input(s) to Base Unit
Volume Of Conductor: 60 Cubic Meter --> 60 Cubic Meter No Conversion Required
Area of Underground AC Wire: 1.28 Square Meter --> 1.28 Square Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
L = V/(2*A) --> 60/(2*1.28)
Evaluating ... ...
L = 23.4375
STEP 3: Convert Result to Output's Unit
23.4375 Meter --> No Conversion Required
FINAL ANSWER
23.4375 Meter <-- Length of Underground AC Wire
(Calculation completed in 00.004 seconds)

Credits

Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verified by Payal Priya
Birsa Institute of Technology (BIT), Sindri
Payal Priya has verified this Calculator and 1900+ more calculators!

14 Wire Parameters Calculators

Length using Area of X-Section (2 Phase 4 Wire US)
Go Length of Underground AC Wire = (Area of Underground AC Wire*Line Losses*(Maximum Voltage Underground AC^2)*(cos(Phase Difference))^2)/(4*Resistivity*(Power Transmitted^2))
Line Losses using Area of X-Section (2 Phase 4 Wire US)
Go Line Losses = 4*Resistivity*Length of Underground AC Wire*(Power Transmitted^2)/(Area of Underground AC Wire*(Maximum Voltage Underground AC^2)*(cos(Phase Difference)^2))
Volume of Conductor Material Main(2 Phase 4 Wire US)
Go Volume Of Conductor = 8*(Power Transmitted^2)*Resistivity*(Length of Underground AC Wire^2)/(Line Losses*(Maximum Voltage Underground AC^2)*(cos(Phase Difference)^2))
Length using Line Losses (2 Phase 4 Wire US)
Go Length of Underground AC Wire = Line Losses*Area of Underground AC Wire/(2*(Current Underground AC^2)*Resistivity)
Area using Line Losses (2 Phase 4 Wire US)
Go Area of Underground AC Wire = (Current Underground AC^2)*2*Resistivity*Length of Underground AC Wire/Line Losses
Line Losses using Load Current (2 Phase 4 Wire US)
Go Line Losses = Current Underground AC^2*2*Resistivity*Length of Underground AC Wire/Area of Underground AC Wire
Volume of Conductor Material using Load Current(2 Phase 4 Wire US)
Go Volume Of Conductor = 16*Resistivity*(Length of Underground AC Wire^2)*(Current Underground AC^2)/Line Losses
Volume of Conductor Material using Load Current (2 Phase 4 Wire US)
Go Volume Of Conductor = (Current Underground AC*Length of Underground AC Wire)^2*4*Resistivity/Line Losses
Line Losses using Volume of Conductor Material (2 Phase 4 Wire US)
Go Line Losses = (Current Underground AC*Length of Underground AC Wire)^2*4*Resistivity/Volume Of Conductor
Volume of Conductor Material using Constant(2 Phase 4 Wire US)
Go Volume Of Conductor = 2*Constant Underground AC/(cos(Phase Difference)^2)
Length using Volume of Conductor Material (2 Phase 4 Wire US)
Go Length of Underground AC Wire = Volume Of Conductor/(2*Area of Underground AC Wire)
Area using Volume of Conductor Material (2 Phase 4 Wire US)
Go Area of Underground AC Wire = Volume Of Conductor/(2*Length of Underground AC Wire)
Volume of Conductor Material (2 Phase 4 Wire US)
Go Volume Of Conductor = 2*Area of Underground AC Wire*Length of Underground AC Wire
Line Losses (2 Phase 4 Wire US)
Go Line Losses = 2*(Current Underground AC^2)*Resistance Underground AC

Length using Volume of Conductor Material (2 Phase 4 Wire US) Formula

Length of Underground AC Wire = Volume Of Conductor/(2*Area of Underground AC Wire)
L = V/(2*A)

What is the volume of conductor material in 2-phase 4-wire underground system?

The volume of conductor material required in this system is 2/cos2θ times that of 2-wire d.c.system with the one conductor earthed.

How to Calculate Length using Volume of Conductor Material (2 Phase 4 Wire US)?

Length using Volume of Conductor Material (2 Phase 4 Wire US) calculator uses Length of Underground AC Wire = Volume Of Conductor/(2*Area of Underground AC Wire) to calculate the Length of Underground AC Wire, The Length using Volume of Conductor Material (2 phase 4 wire US) formula is defined as the total length of the wire that used in the two-phase four-wire system. Length of Underground AC Wire is denoted by L symbol.

How to calculate Length using Volume of Conductor Material (2 Phase 4 Wire US) using this online calculator? To use this online calculator for Length using Volume of Conductor Material (2 Phase 4 Wire US), enter Volume Of Conductor (V) & Area of Underground AC Wire (A) and hit the calculate button. Here is how the Length using Volume of Conductor Material (2 Phase 4 Wire US) calculation can be explained with given input values -> 23.4375 = 60/(2*1.28).

FAQ

What is Length using Volume of Conductor Material (2 Phase 4 Wire US)?
The Length using Volume of Conductor Material (2 phase 4 wire US) formula is defined as the total length of the wire that used in the two-phase four-wire system and is represented as L = V/(2*A) or Length of Underground AC Wire = Volume Of Conductor/(2*Area of Underground AC Wire). Volume Of Conductor the 3-dimensional space enclosed by a conductor material & Area of Underground AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
How to calculate Length using Volume of Conductor Material (2 Phase 4 Wire US)?
The Length using Volume of Conductor Material (2 phase 4 wire US) formula is defined as the total length of the wire that used in the two-phase four-wire system is calculated using Length of Underground AC Wire = Volume Of Conductor/(2*Area of Underground AC Wire). To calculate Length using Volume of Conductor Material (2 Phase 4 Wire US), you need Volume Of Conductor (V) & Area of Underground AC Wire (A). With our tool, you need to enter the respective value for Volume Of Conductor & Area of Underground AC Wire and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Length of Underground AC Wire?
In this formula, Length of Underground AC Wire uses Volume Of Conductor & Area of Underground AC Wire. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Length of Underground AC Wire = Line Losses*Area of Underground AC Wire/(2*(Current Underground AC^2)*Resistivity)
  • Length of Underground AC Wire = (Area of Underground AC Wire*Line Losses*(Maximum Voltage Underground AC^2)*(cos(Phase Difference))^2)/(4*Resistivity*(Power Transmitted^2))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!