Download Line Performance Characteristics PDF

Related PDFs (4)

End Condenser Method in Medium Line
Formulas : 17   Size : 333 kb
Long Transmission Line
Formulas : 26   Size : 396 kb
Nominal Pi-Method in Medium Line
Formulas : 20   Size : 366 kb
Nominal T-Method in Medium Line
Formulas : 19   Size : 354 kb

Contents of the Line Performance Characteristics PDF

List of 15 Line Performance Characteristics Formulas

Base Current
Base Current for Three-Phase System
Base Impedance given Base Current
Base Power
Base Voltage
B-Parameter using Receiving End Reactive Power Component
B-Parameter using Receiving End Real Power Component
Complex Power given Current
Dielectric Loss due to Heating in Cables
Penetration Depth of Eddy Currents
Phase Current for Balanced Three-Phase Delta Connection
Phase Voltage for Balanced Three-Phase Star Connection
Receiving End Real Power Component
Sag of Transmission Line
Skin Depth in Conductor

Variables used in Line Performance Characteristics PDF

  1. ∠α Alpha A-Parameter (Degree)
  2. ∠δ Loss Angle (Degree)
  3. A A Parameter
  4. B B Parameter (Ohm)
  5. C Capacitance (Millifarad)
  6. Df Dielectric Loss (Watt)
  7. f Frequency (Megahertz)
  8. I Electric Current (Ampere)
  9. Ib Base Current (Ampere)
  10. Iline Line Current (Ampere)
  11. Iph Phase Current (Ampere)
  12. Ipu(b) Base Current (PU) (Ampere)
  13. L Span Length (Meter)
  14. P Real Power (Watt)
  15. Pb Base Power (Volt Ampere)
  16. Q Reactive Power (Volt Ampere Reactive)
  17. Rs Specific Resistance (Microhm Centimeter)
  18. s Sag of Transmission Line (Meter)
  19. S Complex Power (Volt Ampere)
  20. T Working Tension (Kilogram)
  21. V Voltage (Volt)
  22. Vbase Base Voltage (Volt)
  23. Vline Line Voltage (Volt)
  24. Vph Phase Voltage (Volt)
  25. Vr Receiving End Voltage (Volt)
  26. Vs Sending End Voltage (Volt)
  27. Wc Weight of Conductor (Kilogram)
  28. Z Impedance (Ohm)
  29. Zbase Base Impedance (Ohm)
  30. β Beta B-Parameter (Degree)
  31. δ Skin Depth (Meter)
  32. δp Penetration Depth (Centimeter)
  33. μ Magnetic Permeability of Medium (Henry per Meter)
  34. μr Relative Permeability
  35. σc Electrical Conductivity (Siemens per Centimeter)
  36. ω Angular Frequency (Radian per Second)

Constants, Functions and Measurements used in Line Performance Characteristics PDF

  1. Constant: pi, 3.14159265358979323846264338327950288
    Archimedes' constant
  2. Function: cos, cos(Angle)
    Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle.
  3. Function: sin, sin(Angle)
    Sine is a trigonometric function that describes the ratio of the length of the opposite side of a right triangle to the length of the hypotenuse.
  4. Function: sqrt, sqrt(Number)
    A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number.
  5. Function: tan, tan(Angle)
    The tangent of an angle is a trigonometric ratio of the length of the side opposite an angle to the length of the side adjacent to an angle in a right triangle.
  6. Measurement: Length in Centimeter (cm), Meter (m)
    Length Unit Conversion
  7. Measurement: Weight in Kilogram (kg)
    Weight Unit Conversion
  8. Measurement: Electric Current in Ampere (A)
    Electric Current Unit Conversion
  9. Measurement: Power in Volt Ampere (VA), Volt Ampere Reactive (VAR), Watt (W)
    Power Unit Conversion
  10. Measurement: Angle in Degree (°)
    Angle Unit Conversion
  11. Measurement: Frequency in Megahertz (MHz)
    Frequency Unit Conversion
  12. Measurement: Capacitance in Millifarad (mF)
    Capacitance Unit Conversion
  13. Measurement: Electric Resistance in Ohm (Ω)
    Electric Resistance Unit Conversion
  14. Measurement: Electric Potential in Volt (V)
    Electric Potential Unit Conversion
  15. Measurement: Electric Resistivity in Microhm Centimeter (μΩ*cm)
    Electric Resistivity Unit Conversion
  16. Measurement: Electric Conductivity in Siemens per Centimeter (S/cm)
    Electric Conductivity Unit Conversion
  17. Measurement: Magnetic Permeability in Henry per Meter (H/m)
    Magnetic Permeability Unit Conversion
  18. Measurement: Angular Frequency in Radian per Second (rad/s)
    Angular Frequency Unit Conversion

Free Line Performance Characteristics PDF

Get Free Line Performance Characteristics PDF for Download today. Examples are included after each Formula with a link to a live Calculator! All the Formulas and Calculators support Unit Conversion as well. This PDF features 15 calculators from Power System. Inside, you'll discover a list of formulas such as Complex Power given Current, Skin Depth in Conductor and 15 more formulas!. The Variables, Functions and Constants are summarized at the end. Explore and share Line Performance Characteristics PDFs!

Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!