Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads Solution

STEP 0: Pre-Calculation Summary
Formula Used
Live Load = (Ultimate Strength-(1.4*Dead Load))/(1.7)
LL = (U-(1.4*DL))/(1.7)
This formula uses 3 Variables
Variables Used
Live Load - (Measured in Pascal) - Live Load are variable as they depend on usage and capacity.
Ultimate Strength - (Measured in Pascal) - ultimate strengths is the capacities to resist design loads and their related internal moments and forces.
Dead Load - (Measured in Pascal) - Dead Load consisting of basic load plus volume change due to (shrinkage,temperature).
STEP 1: Convert Input(s) to Base Unit
Ultimate Strength: 20 Kilonewton per Square Meter --> 20000 Pascal (Check conversion here)
Dead Load: 10.01 Kilonewton per Square Meter --> 10010 Pascal (Check conversion here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
LL = (U-(1.4*DL))/(1.7) --> (20000-(1.4*10010))/(1.7)
Evaluating ... ...
LL = 3521.17647058824
STEP 3: Convert Result to Output's Unit
3521.17647058824 Pascal -->3.52117647058824 Kilonewton per Square Meter (Check conversion here)
FINAL ANSWER
3.52117647058824 3.521176 Kilonewton per Square Meter <-- Live Load
(Calculation completed in 00.004 seconds)

Credits

Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verified by Alithea Fernandes
Don Bosco College of Engineering (DBCE), Goa
Alithea Fernandes has verified this Calculator and 100+ more calculators!

6 Partial Safety Factors for Loads Calculators

Basic Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads
Go Dead Load = (Ultimate Strength-(1.7*Live Load))/(1.4)
Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads
Go Live Load = (Ultimate Strength-(1.4*Dead Load))/(1.7)
Basic Load Effect given Ultimate Strength for Applied Wind Loads
Go Dead Load = (Ultimate Strength-(1.3*Wind Load))/(0.9)
Wind Load Effect given Ultimate Strength for Applied Wind Loads
Go Wind Load = (Ultimate Strength-(0.9*Dead Load))/(1.3)
Ultimate Strength when Wind and Earthquake Loads are not Applied
Go Ultimate Strength = (1.4*Dead Load)+(1.7*Live Load)
Ultimate Strength when Wind Loads are Applied
Go Ultimate Strength = (0.9*Dead Load)+(1.3*Wind Load)

Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads Formula

Live Load = (Ultimate Strength-(1.4*Dead Load))/(1.7)
LL = (U-(1.4*DL))/(1.7)

What is Live Load?

Live loads are those loads produced by the use and occupancy of a building or structure and do not include construction loads, environmental loads (such as wind loads, snow loads, rain loads, earthquake loads and flood loads) or dead loads

What is Dead Load?

A constant load in a structure (such as a bridge, building, or machine) that is due to the weight of the members, the supported structure, and permanent attachments or accessories.

How to Calculate Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads?

Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads calculator uses Live Load = (Ultimate Strength-(1.4*Dead Load))/(1.7) to calculate the Live Load, The Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads formula is defined as those loads produced by the use and occupancy of a building or structure and do not include construction loads, environmental loads (such as wind loads, snow loads, rain loads, earthquake loads and flood loads) or dead loads. Live Load is denoted by LL symbol.

How to calculate Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads using this online calculator? To use this online calculator for Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads, enter Ultimate Strength (U) & Dead Load (DL) and hit the calculate button. Here is how the Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads calculation can be explained with given input values -> 0.003529 = (20000-(1.4*10010))/(1.7).

FAQ

What is Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads?
The Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads formula is defined as those loads produced by the use and occupancy of a building or structure and do not include construction loads, environmental loads (such as wind loads, snow loads, rain loads, earthquake loads and flood loads) or dead loads and is represented as LL = (U-(1.4*DL))/(1.7) or Live Load = (Ultimate Strength-(1.4*Dead Load))/(1.7). ultimate strengths is the capacities to resist design loads and their related internal moments and forces & Dead Load consisting of basic load plus volume change due to (shrinkage,temperature).
How to calculate Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads?
The Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads formula is defined as those loads produced by the use and occupancy of a building or structure and do not include construction loads, environmental loads (such as wind loads, snow loads, rain loads, earthquake loads and flood loads) or dead loads is calculated using Live Load = (Ultimate Strength-(1.4*Dead Load))/(1.7). To calculate Live Load Effect given Ultimate Strength for Unapplied Wind and Earthquake Loads, you need Ultimate Strength (U) & Dead Load (DL). With our tool, you need to enter the respective value for Ultimate Strength & Dead Load and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!