Local extension of mild steel bar Solution

STEP 0: Pre-Calculation Summary
Formula Used
Local Extension = Coefficient of Elongation*sqrt(Cross-sectional Area of Specimen)
y = S*sqrt(A)
This formula uses 1 Functions, 3 Variables
Functions Used
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
Local Extension - (Measured in Meter) - Local Extension is defined when an object increases in length, and compression happens when it decreases in length.
Coefficient of Elongation - Coefficient of Elongation refers to the coefficient used in unwin equation of local extension.
Cross-sectional Area of Specimen - (Measured in Square Meter) - Cross-sectional Area of Specimen is the area exposed when specimen is cut transversely.
STEP 1: Convert Input(s) to Base Unit
Coefficient of Elongation: 0.3 --> No Conversion Required
Cross-sectional Area of Specimen: 0.002027 Square Meter --> 0.002027 Square Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
y = S*sqrt(A) --> 0.3*sqrt(0.002027)
Evaluating ... ...
y = 0.0135066650213885
STEP 3: Convert Result to Output's Unit
0.0135066650213885 Meter -->13.5066650213885 Millimeter (Check conversion here)
FINAL ANSWER
13.5066650213885 13.50667 Millimeter <-- Local Extension
(Calculation completed in 00.004 seconds)

Credits

Created by sanjay shiva
national institute of technology hamirpur (NITH ), hamirpur , himachal pradesh
sanjay shiva has created this Calculator and 100+ more calculators!
Verified by Anshika Arya
National Institute Of Technology (NIT), Hamirpur
Anshika Arya has verified this Calculator and 2500+ more calculators!

8 Measurement of Ductility of Metal Calculators

Load given Brinell Hardness Number
Go Load = (Brinell Hardness Number*pi*Steel Ball Diameter*(Steel Ball Diameter-sqrt(Steel Ball Diameter^2-Depression Diameter^2)))/2
Total Extension given Area of Mild Steel bar
Go Total Extension = Coefficient of Elongation*sqrt(Cross-sectional Area of Specimen)+(Coefficient of Extension*Initial Length)
Percentage Elongation of Mild Steel Test Bar
Go Percentage Elongation = ((Initial Length-Length of Test Bar at Fracture)/Length of Test Bar at Fracture)*100
Local extension of mild steel bar
Go Local Extension = Coefficient of Elongation*sqrt(Cross-sectional Area of Specimen)
Original Length of Mild Steel test bar given Total Extension
Go Initial Length = (Total Extension-Total Elongation)/Coefficient of Extension
Total Extension of Mild Steel Test Bar
Go Total Extension = Total Elongation+Coefficient of Extension*Initial Length
Area of Mild Steel bar given Local Extension
Go Cross-sectional Area of Specimen = (Local Extension/Coefficient of Elongation)^2
Gross area design strength for steel
Go Design Strength = Gross Area of Cross-Section*Yield Strength/1.1

Local extension of mild steel bar Formula

Local Extension = Coefficient of Elongation*sqrt(Cross-sectional Area of Specimen)
y = S*sqrt(A)

What is the meaning of the word extension?

In metaphysics, extension signifies both 'stretching out' (Latin: extensio) as well as later 'taking up space', and most recently, spreading one's internal mental cognition into the external world.

How to Calculate Local extension of mild steel bar?

Local extension of mild steel bar calculator uses Local Extension = Coefficient of Elongation*sqrt(Cross-sectional Area of Specimen) to calculate the Local Extension, The Local extension of mild steel bar formula is defined as when an object increases in length and compression happens when it decreases in length. Local Extension is denoted by y symbol.

How to calculate Local extension of mild steel bar using this online calculator? To use this online calculator for Local extension of mild steel bar, enter Coefficient of Elongation (S) & Cross-sectional Area of Specimen (A) and hit the calculate button. Here is how the Local extension of mild steel bar calculation can be explained with given input values -> 10392.3 = 0.3*sqrt(0.002027).

FAQ

What is Local extension of mild steel bar?
The Local extension of mild steel bar formula is defined as when an object increases in length and compression happens when it decreases in length and is represented as y = S*sqrt(A) or Local Extension = Coefficient of Elongation*sqrt(Cross-sectional Area of Specimen). Coefficient of Elongation refers to the coefficient used in unwin equation of local extension & Cross-sectional Area of Specimen is the area exposed when specimen is cut transversely.
How to calculate Local extension of mild steel bar?
The Local extension of mild steel bar formula is defined as when an object increases in length and compression happens when it decreases in length is calculated using Local Extension = Coefficient of Elongation*sqrt(Cross-sectional Area of Specimen). To calculate Local extension of mild steel bar, you need Coefficient of Elongation (S) & Cross-sectional Area of Specimen (A). With our tool, you need to enter the respective value for Coefficient of Elongation & Cross-sectional Area of Specimen and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!