Machine Construction Constant of DC Shunt Motor given Angular Speed Solution

STEP 0: Pre-Calculation Summary
Formula Used
Constant of Machine Construction = Back EMF/(Magnetic Flux*Angular Speed)
Kf = Eb/(Φ*ωs)
This formula uses 4 Variables
Variables Used
Constant of Machine Construction - Constant of Machine construction is a constant term which is calculated separately to a make calculation less complex.
Back EMF - (Measured in Volt) - The Back emf opposes the current which causes it in any dc machine. Back emf refers to the voltage that is generated in an inductor or a coil of wire when the current flowing through it changes.
Magnetic Flux - (Measured in Weber) - Magnetic flux (Φ) is the number of magnetic field lines passing through the magnetic core of an electrical dc motor.
Angular Speed - (Measured in Radian per Second) - Angular speed refers to the rate at which an object rotates around an axis. In the context of a DC (direct current) motor, angular speed represents how fast the motor's rotor is spinning.
STEP 1: Convert Input(s) to Base Unit
Back EMF: 231 Volt --> 231 Volt No Conversion Required
Magnetic Flux: 0.114 Weber --> 0.114 Weber No Conversion Required
Angular Speed: 161 Revolution per Second --> 1011.5928344044 Radian per Second (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Kf = Eb/(Φ*ωs) --> 231/(0.114*1011.5928344044)
Evaluating ... ...
Kf = 2.00309424954233
STEP 3: Convert Result to Output's Unit
2.00309424954233 --> No Conversion Required
FINAL ANSWER
2.00309424954233 2.003094 <-- Constant of Machine Construction
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

7 Mechanical Specifications Calculators

Machine Construction Constant using Speed of Shunt DC Motor
​ Go Constant of Machine Construction = (Terminal Voltage-Armature Current*Armature Resistance)/(Motor Speed*Magnetic Flux)
Machine Construction Constant of Shunt DC Motor
​ Go Constant of Machine Construction = (60*Number of Parallel Paths)/(Number of Poles*Number of Conductors)
Number of Armature Conductors of DC Shunt Motor using K
​ Go Number of Conductors = (60*Number of Parallel Paths)/(Machine Constant*Number of Poles)
Number of Poles of Shunt DC Motor
​ Go Number of Poles = (60*Number of Parallel Paths)/(Machine Constant*Number of Conductors)
Number of Parallel Paths of Shunt DC Motor
​ Go Number of Parallel Paths = (Machine Constant*Number of Conductors*Number of Poles)/60
Machine Construction Constant of DC Shunt Motor given Angular Speed
​ Go Constant of Machine Construction = Back EMF/(Magnetic Flux*Angular Speed)
Machine Constant of DC Shunt Motor given Torque
​ Go Machine Constant = Torque/(Magnetic Flux*Armature Current)

Machine Construction Constant of DC Shunt Motor given Angular Speed Formula

Constant of Machine Construction = Back EMF/(Magnetic Flux*Angular Speed)
Kf = Eb/(Φ*ωs)

What is a DC shunt motor?

A DC shunt motor is a type of self-excited DC motor, and it is also known as a shunt wound DC motor. The field windings in this motor can be connected in parallel to the armature winding.

How to Calculate Machine Construction Constant of DC Shunt Motor given Angular Speed?

Machine Construction Constant of DC Shunt Motor given Angular Speed calculator uses Constant of Machine Construction = Back EMF/(Magnetic Flux*Angular Speed) to calculate the Constant of Machine Construction, The Machine Construction Constant of DC Shunt Motor given Angular Speed formula is defined as a constant based on machine construction that is required to find all the basic quality of the machine. Constant of Machine Construction is denoted by Kf symbol.

How to calculate Machine Construction Constant of DC Shunt Motor given Angular Speed using this online calculator? To use this online calculator for Machine Construction Constant of DC Shunt Motor given Angular Speed, enter Back EMF (Eb), Magnetic Flux (Φ) & Angular Speed s) and hit the calculate button. Here is how the Machine Construction Constant of DC Shunt Motor given Angular Speed calculation can be explained with given input values -> 1.994423 = 231/(0.114*1011.5928344044).

FAQ

What is Machine Construction Constant of DC Shunt Motor given Angular Speed?
The Machine Construction Constant of DC Shunt Motor given Angular Speed formula is defined as a constant based on machine construction that is required to find all the basic quality of the machine and is represented as Kf = Eb/(Φ*ωs) or Constant of Machine Construction = Back EMF/(Magnetic Flux*Angular Speed). The Back emf opposes the current which causes it in any dc machine. Back emf refers to the voltage that is generated in an inductor or a coil of wire when the current flowing through it changes, Magnetic flux (Φ) is the number of magnetic field lines passing through the magnetic core of an electrical dc motor & Angular speed refers to the rate at which an object rotates around an axis. In the context of a DC (direct current) motor, angular speed represents how fast the motor's rotor is spinning.
How to calculate Machine Construction Constant of DC Shunt Motor given Angular Speed?
The Machine Construction Constant of DC Shunt Motor given Angular Speed formula is defined as a constant based on machine construction that is required to find all the basic quality of the machine is calculated using Constant of Machine Construction = Back EMF/(Magnetic Flux*Angular Speed). To calculate Machine Construction Constant of DC Shunt Motor given Angular Speed, you need Back EMF (Eb), Magnetic Flux (Φ) & Angular Speed s). With our tool, you need to enter the respective value for Back EMF, Magnetic Flux & Angular Speed and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Constant of Machine Construction?
In this formula, Constant of Machine Construction uses Back EMF, Magnetic Flux & Angular Speed. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Constant of Machine Construction = (60*Number of Parallel Paths)/(Number of Poles*Number of Conductors)
  • Constant of Machine Construction = (Terminal Voltage-Armature Current*Armature Resistance)/(Motor Speed*Magnetic Flux)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!