Maximal Variation of Cutoff Angular Frequency Solution

STEP 0: Pre-Calculation Summary
Formula Used
Maximal Variation = (Cutoff Angular Frequency*Sample Signal Window*Clock Count)/Central Frequency
M = (ωco*Wss*K)/fce
This formula uses 5 Variables
Variables Used
Maximal Variation - Maximal Variation, also known as heterogeneous sampling, is used to capture the widest range of perspectives possible.
Cutoff Angular Frequency - (Measured in Radian per Second) - Cutoff Angular Frequency is the frequency either above or below which the power output of a circuit.
Sample Signal Window - Sample Signal Window typically refers to a specific section or range within a signal where sampling or analysis is performed. In various fields like signal processing.
Clock Count - (Measured in Second) - Clock Count refers counts up from a past event.
Central Frequency - (Measured in Hertz) - Central frequency refers to the dominant frequency in a carrier signal, also known as the signal's mid-point frequency.
STEP 1: Convert Input(s) to Base Unit
Cutoff Angular Frequency: 0.96 Radian per Second --> 0.96 Radian per Second No Conversion Required
Sample Signal Window: 7 --> No Conversion Required
Clock Count: 3 Second --> 3 Second No Conversion Required
Central Frequency: 2.52 Hertz --> 2.52 Hertz No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
M = (ωco*Wss*K)/fce --> (0.96*7*3)/2.52
Evaluating ... ...
M = 8
STEP 3: Convert Result to Output's Unit
8 --> No Conversion Required
FINAL ANSWER
8 <-- Maximal Variation
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Rahul Gupta
Chandigarh University (CU), Mohali, Punjab
Rahul Gupta has created this Calculator and 25+ more calculators!
Verifier Image
Verified by Ritwik Tripathi
Vellore Institute of Technology (VIT Vellore), Vellore
Ritwik Tripathi has verified this Calculator and 100+ more calculators!

14 Discrete Time Signals Calculators

Triangular Window
​ Go Triangular Window = 0.42-0.52*cos((2*pi*Number of Samples)/(Sample Signal Window-1))-0.08*cos((4*pi*Number of Samples)/(Sample Signal Window-1))
Damping Coefficient of Second Order Transmittance
​ Go Damping Coefficient = (1/2)*Input Resistance*Initial Capacitance*sqrt((Transmittance Filtering*Input Inductance)/(Sample Signal Window*Initial Capacitance))
Fourier Transform of Rectangular Window
​ Go Rectangular Window = sin(2*pi*Unlimited Time Signal*Input Periodic Frequency)/(pi*Input Periodic Frequency)
Sampling Frequency of Bilinear
​ Go Sampling Frequency = (pi*Distortion Frequency)/arctan((2*pi*Distortion Frequency)/Bilinear Frequency)
Bilinear Transformation Frequency
​ Go Bilinear Frequency = (2*pi*Distortion Frequency)/tan(pi*Distortion Frequency/Sampling Frequency)
Natural Angular Frequency of Second Order Transmittance
​ Go Natural Angular Frequency = sqrt((Transmittance Filtering*Input Inductance)/(Sample Signal Window*Initial Capacitance))
Cutoff Angular Frequency
​ Go Cutoff Angular Frequency = (Maximal Variation*Central Frequency)/(Sample Signal Window*Clock Count)
Maximal Variation of Cutoff Angular Frequency
​ Go Maximal Variation = (Cutoff Angular Frequency*Sample Signal Window*Clock Count)/Central Frequency
Inverse Transmittance Filtering
​ Go Inverse Transmittance Filtering = (sinc(pi*Input Periodic Frequency/Sampling Frequency))^-1
Hanning Window
​ Go Hanning Window = 1/2-(1/2)*cos((2*pi*Number of Samples)/(Sample Signal Window-1))
Hamming Window
​ Go Hamming Window = 0.54-0.46*cos((2*pi*Number of Samples)/(Sample Signal Window-1))
Transmittance Filtering
​ Go Transmittance Filtering = sinc(pi*(Input Periodic Frequency/Sampling Frequency))
Initial Frequency of Dirac Comb Angle
​ Go Initial Frequency = (2*pi*Input Periodic Frequency)/Signal Angle
Frequency Dirac Comb Angle
​ Go Signal Angle = 2*pi*Input Periodic Frequency*1/Initial Frequency

Maximal Variation of Cutoff Angular Frequency Formula

Maximal Variation = (Cutoff Angular Frequency*Sample Signal Window*Clock Count)/Central Frequency
M = (ωco*Wss*K)/fce

What is the upper cut-off frequency and lower cutoff frequency?

The first cutoff frequency is from a high pass filter, known as the higher cutoff frequency. This cut-off frequency is known as FC high. The second cutoff frequency is from the low pass filter known as the lower cutoff frequency. This cut-off frequency is known as FC low.

How to Calculate Maximal Variation of Cutoff Angular Frequency?

Maximal Variation of Cutoff Angular Frequency calculator uses Maximal Variation = (Cutoff Angular Frequency*Sample Signal Window*Clock Count)/Central Frequency to calculate the Maximal Variation, The Maximal Variation of Cutoff Angular Frequency formula is defined as the frequency at which the power of the signal is reduced to half of its original value. Maximal Variation is denoted by M symbol.

How to calculate Maximal Variation of Cutoff Angular Frequency using this online calculator? To use this online calculator for Maximal Variation of Cutoff Angular Frequency, enter Cutoff Angular Frequency co), Sample Signal Window (Wss), Clock Count (K) & Central Frequency (fce) and hit the calculate button. Here is how the Maximal Variation of Cutoff Angular Frequency calculation can be explained with given input values -> 8 = (0.96*7*3)/2.52.

FAQ

What is Maximal Variation of Cutoff Angular Frequency?
The Maximal Variation of Cutoff Angular Frequency formula is defined as the frequency at which the power of the signal is reduced to half of its original value and is represented as M = (ωco*Wss*K)/fce or Maximal Variation = (Cutoff Angular Frequency*Sample Signal Window*Clock Count)/Central Frequency. Cutoff Angular Frequency is the frequency either above or below which the power output of a circuit, Sample Signal Window typically refers to a specific section or range within a signal where sampling or analysis is performed. In various fields like signal processing, Clock Count refers counts up from a past event & Central frequency refers to the dominant frequency in a carrier signal, also known as the signal's mid-point frequency.
How to calculate Maximal Variation of Cutoff Angular Frequency?
The Maximal Variation of Cutoff Angular Frequency formula is defined as the frequency at which the power of the signal is reduced to half of its original value is calculated using Maximal Variation = (Cutoff Angular Frequency*Sample Signal Window*Clock Count)/Central Frequency. To calculate Maximal Variation of Cutoff Angular Frequency, you need Cutoff Angular Frequency co), Sample Signal Window (Wss), Clock Count (K) & Central Frequency (fce). With our tool, you need to enter the respective value for Cutoff Angular Frequency, Sample Signal Window, Clock Count & Central Frequency and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!