Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load Solution

STEP 0: Pre-Calculation Summary
Formula Used
Peak Output Voltage Thyristor Converter = Peak Input Voltage Thyristor Converter/pi
Vom(thy) = Vin(thy)/pi
This formula uses 1 Constants, 2 Variables
Constants Used
pi - Archimedes' constant Value Taken As 3.14159265358979323846264338327950288
Variables Used
Peak Output Voltage Thyristor Converter - (Measured in Volt) - Peak Output Voltage Thyristor Converter is defined as the peak amplitude obtained by the voltage at the output terminal of a thyristor based converter circuit.
Peak Input Voltage Thyristor Converter - (Measured in Volt) - Peak Input Voltage Thyristor Converter is defined as the peak amplitude obtained by the voltage at the input terminal of a thyristor based converter circuit.
STEP 1: Convert Input(s) to Base Unit
Peak Input Voltage Thyristor Converter: 12 Volt --> 12 Volt No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Vom(thy) = Vin(thy)/pi --> 12/pi
Evaluating ... ...
Vom(thy) = 3.81971863420549
STEP 3: Convert Result to Output's Unit
3.81971863420549 Volt --> No Conversion Required
FINAL ANSWER
3.81971863420549 3.819719 Volt <-- Peak Output Voltage Thyristor Converter
(Calculation completed in 00.004 seconds)

Credits

Created by Devyaani Garg
Shiv Nadar University (SNU), Greater Noida
Devyaani Garg has created this Calculator and 50+ more calculators!
Verified by Nikita Suryawanshi
Vellore Institute of Technology (VIT), Vellore
Nikita Suryawanshi has verified this Calculator and 25+ more calculators!

5 Single Phase Thyristor Converter Calculators

RMS Output Voltage of Single Phase Thyristor Converter with Resistive Load
Go RMS Voltage Thyristor Converter = (Peak Input Voltage Thyristor Converter/2)*((180-Delay Angle of Thyristor Converter)/180+(0.5/pi)*sin(2*Delay Angle of Thyristor Converter))^0.5
Average Load Voltage for Calculus Function
Go Average Voltage Thyristor Converter = ((1/(2*pi))*int(Peak Input Voltage Thyristor Converter*sin(x),x,Firing Angle of Thyristor Converter,pi))
Average Output Voltage of Single Phase Thyristor Converter with Resistive Load
Go Average Voltage Thyristor Converter = (Peak Input Voltage Thyristor Converter/(2*pi))*(1+cos(Delay Angle of Thyristor Converter))
Normalized Voltage of Single Phase Thyristor Converter with Resistive Load
Go Normalized Output Voltage Thyristor Converter = 0.5*(1+cos(Delay Angle of Thyristor Converter))
Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load
Go Peak Output Voltage Thyristor Converter = Peak Input Voltage Thyristor Converter/pi

Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load Formula

Peak Output Voltage Thyristor Converter = Peak Input Voltage Thyristor Converter/pi
Vom(thy) = Vin(thy)/pi

What is the use thyristor?

Thyristors are mainly used where high currents and voltages are involved, and are often used to control alternating currents, where the change of polarity of the current causes the device to switch off automatically, referred to as "zero cross" operation

How to Calculate Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load?

Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load calculator uses Peak Output Voltage Thyristor Converter = Peak Input Voltage Thyristor Converter/pi to calculate the Peak Output Voltage Thyristor Converter, The Maximum output voltage of single phase thyristor converter with resistive load is the ratio of peak input voltage and pi = 3.14. Peak Output Voltage Thyristor Converter is denoted by Vom(thy) symbol.

How to calculate Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load using this online calculator? To use this online calculator for Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load, enter Peak Input Voltage Thyristor Converter (Vin(thy)) and hit the calculate button. Here is how the Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load calculation can be explained with given input values -> 3.819719 = 12/pi.

FAQ

What is Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load?
The Maximum output voltage of single phase thyristor converter with resistive load is the ratio of peak input voltage and pi = 3.14 and is represented as Vom(thy) = Vin(thy)/pi or Peak Output Voltage Thyristor Converter = Peak Input Voltage Thyristor Converter/pi. Peak Input Voltage Thyristor Converter is defined as the peak amplitude obtained by the voltage at the input terminal of a thyristor based converter circuit.
How to calculate Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load?
The Maximum output voltage of single phase thyristor converter with resistive load is the ratio of peak input voltage and pi = 3.14 is calculated using Peak Output Voltage Thyristor Converter = Peak Input Voltage Thyristor Converter/pi. To calculate Maximum Output Voltage of Single Phase Thyristor Converter with Resistive Load, you need Peak Input Voltage Thyristor Converter (Vin(thy)). With our tool, you need to enter the respective value for Peak Input Voltage Thyristor Converter and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.