Maximum Power for Iron Loss in Power Factor Correction Solution

STEP 0: Pre-Calculation Summary
Formula Used
Maximum Load Power = 0.02*Transformer Stack Rating
Pmax = 0.02*Stfr
This formula uses 2 Variables
Variables Used
Maximum Load Power - (Measured in Watt) - Maximum Load Power is defined as the maximum power that can be transferred from the input of the circuit to its output.
Transformer Stack Rating - (Measured in Watt) - Transformer Stack Rating is defined as the capacity for handling electrical power. It is required to know how much power the transformer can safely and effectively transfer.
STEP 1: Convert Input(s) to Base Unit
Transformer Stack Rating: 51 Volt Ampere --> 51 Watt (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Pmax = 0.02*Stfr --> 0.02*51
Evaluating ... ...
Pmax = 1.02
STEP 3: Convert Result to Output's Unit
1.02 Watt --> No Conversion Required
FINAL ANSWER
1.02 Watt <-- Maximum Load Power
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Mohamed Fazil V
Acharya institute of technology (AIT), Bengaluru
Mohamed Fazil V has created this Calculator and 50+ more calculators!
Verifier Image
Verified by Aman Dhussawat
GURU TEGH BAHADUR INSTITUTE OF TECHNOLOGY (GTBIT), NEW DELHI
Aman Dhussawat has verified this Calculator and 100+ more calculators!

7 Power Factor Correction Calculators

Compensated Reactive Power for Mechanical Loads Power Factor
​ Go Compensated Reactive Power 2 = Maximum Load Power*(tan(Inverse Cosine 1)-tan(Inverse Cosine 2))
Actual Power Factor Correction
​ Go Power Factor = cos(tanh(tan(Initial Power Factor)-Corrected Current in AC Circuit))
Active Power in Three Phase (L-L) AC Circuits
​ Go Active Power in DC Circuit = sqrt(3)*Line Voltage*Line Current*cos(Phase Angle)
Capacitor Banking Reactive Power
​ Go Capacitor Banking Reactive = Capacitance*2*pi*Frequency in Capacitor Banking*(Voltage)^2*10^-9
Active Power in Single Phase AC Circuits
​ Go Active Power in DC Circuit = Voltage*Corrected Current in AC Circuit*cos(Phase Angle)
Copper Loss of Power Factor Correction
​ Go Copper Loss = (Impedence Voltage/100)*Transformer Stack Rating
Maximum Power for Iron Loss in Power Factor Correction
​ Go Maximum Load Power = 0.02*Transformer Stack Rating

Maximum Power for Iron Loss in Power Factor Correction Formula

Maximum Load Power = 0.02*Transformer Stack Rating
Pmax = 0.02*Stfr

What is Maximum Power for Iron Loss in Power Factor Correction ?

The maximum power for iron loss, also known as core loss or hysteresis loss, refers to the maximum amount of power that can be dissipated in the core of an electrical transformer or other magnetic device due to magnetic hysteresis and eddy currents. This maximum power for iron loss is typically specified by the manufacturer and depends on various factors such as the core material, operating frequency, core geometry, and temperature.

How to Calculate Maximum Power for Iron Loss in Power Factor Correction?

Maximum Power for Iron Loss in Power Factor Correction calculator uses Maximum Load Power = 0.02*Transformer Stack Rating to calculate the Maximum Load Power, Maximum Power for Iron Loss in Power Factor Correction refers to the energy losses that occur in the iron core of a transformer when it is energized even without any load connected (no-load condition). Power factor correction aims to improve the efficiency of AC power systems by minimizing the reactive power component. Reactive power doesn't do any actual work but contributes to the apparent power, leading to higher current flow and increased losses. Maximum Load Power is denoted by Pmax symbol.

How to calculate Maximum Power for Iron Loss in Power Factor Correction using this online calculator? To use this online calculator for Maximum Power for Iron Loss in Power Factor Correction, enter Transformer Stack Rating (Stfr) and hit the calculate button. Here is how the Maximum Power for Iron Loss in Power Factor Correction calculation can be explained with given input values -> 1.02 = 0.02*51.

FAQ

What is Maximum Power for Iron Loss in Power Factor Correction?
Maximum Power for Iron Loss in Power Factor Correction refers to the energy losses that occur in the iron core of a transformer when it is energized even without any load connected (no-load condition). Power factor correction aims to improve the efficiency of AC power systems by minimizing the reactive power component. Reactive power doesn't do any actual work but contributes to the apparent power, leading to higher current flow and increased losses and is represented as Pmax = 0.02*Stfr or Maximum Load Power = 0.02*Transformer Stack Rating. Transformer Stack Rating is defined as the capacity for handling electrical power. It is required to know how much power the transformer can safely and effectively transfer.
How to calculate Maximum Power for Iron Loss in Power Factor Correction?
Maximum Power for Iron Loss in Power Factor Correction refers to the energy losses that occur in the iron core of a transformer when it is energized even without any load connected (no-load condition). Power factor correction aims to improve the efficiency of AC power systems by minimizing the reactive power component. Reactive power doesn't do any actual work but contributes to the apparent power, leading to higher current flow and increased losses is calculated using Maximum Load Power = 0.02*Transformer Stack Rating. To calculate Maximum Power for Iron Loss in Power Factor Correction, you need Transformer Stack Rating (Stfr). With our tool, you need to enter the respective value for Transformer Stack Rating and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.