Maximum Specific Humidity Solution

STEP 0: Pre-Calculation Summary
Formula Used
Maximum Specific Humidity = (0.622*Partial Pressure of Water Vapour in Saturated Air)/(Total Pressure of Moist Air-Partial Pressure of Water Vapour in Saturated Air)
ωmax = (0.622*ps)/(pt-ps)
This formula uses 3 Variables
Variables Used
Maximum Specific Humidity - Maximum Specific Humidity is the specific humidity for the saturated air when the air is holding the maximum amount of water vapor.
Partial Pressure of Water Vapour in Saturated Air - (Measured in Pascal) - Partial pressure of water vapour in saturated air is obtained from the steam tables corresponding to dry bulb temperature.
Total Pressure of Moist Air - (Measured in Pascal) - Total Pressure of Moist Air is the pressure exerted by the mixture of air and water vapour which is equal to the sum of the respected pressures. It is also called barometric pressure.
STEP 1: Convert Input(s) to Base Unit
Partial Pressure of Water Vapour in Saturated Air: 91 Bar --> 9100000 Pascal (Check conversion here)
Total Pressure of Moist Air: 100 Bar --> 10000000 Pascal (Check conversion here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
ωmax = (0.622*ps)/(pt-ps) --> (0.622*9100000)/(10000000-9100000)
Evaluating ... ...
ωmax = 6.28911111111111
STEP 3: Convert Result to Output's Unit
6.28911111111111 --> No Conversion Required
FINAL ANSWER
6.28911111111111 6.289111 <-- Maximum Specific Humidity
(Calculation completed in 00.004 seconds)

Credits

Created by Ravi Khiyani
Shri Govindram Seksaria Institute of Technology and Science (SGSITS), Indore
Ravi Khiyani has created this Calculator and 200+ more calculators!
Verified by Anshika Arya
National Institute Of Technology (NIT), Hamirpur
Anshika Arya has verified this Calculator and 2500+ more calculators!

7 Specific Humidity Calculators

Maximum Specific Humidity
Go Maximum Specific Humidity = (0.622*Partial Pressure of Water Vapour in Saturated Air)/(Total Pressure of Moist Air-Partial Pressure of Water Vapour in Saturated Air)
Specific Humidity given Partial Pressure of Water Vapor
Go Specific Humidity = (0.622*Pressure of Water Vapor)/(Total Pressure of Moist Air-Pressure of Water Vapor)
Total Pressure of Moist Air given Specific Humidity
Go Total Pressure of Moist Air = Pressure of Water Vapor+(0.622*Pressure of Water Vapor)/Specific Humidity
Partial Pressure of Water Vapor given Specific Humidity
Go Pressure of Water Vapor = Total Pressure of Moist Air/(1+0.622/Specific Humidity)
Partial Pressure of Dry Air given Specific Humidity
Go Partial Pressure of Dry Air = (0.622*Pressure of Water Vapor)/Specific Humidity
Specific Humidity given Specific Volumes
Go Specific Humidity = Specific Volume of Dry Air/Specific Volume of Water Vapor
Specific Humidity given Mass of Water Vapor and Dry Air
Go Specific Humidity = Mass of Water Vapor in Moist Air/Mass of Dry Air

Maximum Specific Humidity Formula

Maximum Specific Humidity = (0.622*Partial Pressure of Water Vapour in Saturated Air)/(Total Pressure of Moist Air-Partial Pressure of Water Vapour in Saturated Air)
ωmax = (0.622*ps)/(pt-ps)

What is Specific Humidity?

Specific humidity can be defined as the mass of water vapor in a unit mass of moist air, usually expressed as grams of vapor per kilogram of air or in air conditioning as grains per pound.

How to Calculate Maximum Specific Humidity?

Maximum Specific Humidity calculator uses Maximum Specific Humidity = (0.622*Partial Pressure of Water Vapour in Saturated Air)/(Total Pressure of Moist Air-Partial Pressure of Water Vapour in Saturated Air) to calculate the Maximum Specific Humidity, The Maximum Specific Humidity formula calculates the specific humidity for the saturated air when the air is holding the maximum amount of water vapor. Maximum Specific Humidity is denoted by ωmax symbol.

How to calculate Maximum Specific Humidity using this online calculator? To use this online calculator for Maximum Specific Humidity, enter Partial Pressure of Water Vapour in Saturated Air (ps) & Total Pressure of Moist Air (pt) and hit the calculate button. Here is how the Maximum Specific Humidity calculation can be explained with given input values -> 6.289111 = (0.622*9100000)/(10000000-9100000).

FAQ

What is Maximum Specific Humidity?
The Maximum Specific Humidity formula calculates the specific humidity for the saturated air when the air is holding the maximum amount of water vapor and is represented as ωmax = (0.622*ps)/(pt-ps) or Maximum Specific Humidity = (0.622*Partial Pressure of Water Vapour in Saturated Air)/(Total Pressure of Moist Air-Partial Pressure of Water Vapour in Saturated Air). Partial pressure of water vapour in saturated air is obtained from the steam tables corresponding to dry bulb temperature & Total Pressure of Moist Air is the pressure exerted by the mixture of air and water vapour which is equal to the sum of the respected pressures. It is also called barometric pressure.
How to calculate Maximum Specific Humidity?
The Maximum Specific Humidity formula calculates the specific humidity for the saturated air when the air is holding the maximum amount of water vapor is calculated using Maximum Specific Humidity = (0.622*Partial Pressure of Water Vapour in Saturated Air)/(Total Pressure of Moist Air-Partial Pressure of Water Vapour in Saturated Air). To calculate Maximum Specific Humidity, you need Partial Pressure of Water Vapour in Saturated Air (ps) & Total Pressure of Moist Air (pt). With our tool, you need to enter the respective value for Partial Pressure of Water Vapour in Saturated Air & Total Pressure of Moist Air and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!