Mechanical Power Developed in DC Motor given Input Power Solution

STEP 0: Pre-Calculation Summary
Formula Used
Mechanical Power = Input Power-(Armature Current^2*Armature Resistance)
Pm = Pin-(Ia^2*Ra)
This formula uses 4 Variables
Variables Used
Mechanical Power - (Measured in Watt) - Mechanical Power is the product of a force on an object and the object's velocity or the product of torque on a shaft and the shaft's angular velocity.
Input Power - (Measured in Watt) - Input Power is defined as the total power supplied to the electrical dc motor from the source which is connected to it.
Armature Current - (Measured in Ampere) - Armature Current DC motor is defined as the armature current developed in an electrical dc motor due to the rotation of rotor.
Armature Resistance - (Measured in Ohm) - The Armature Resistance is the ohmic resistance of the copper winding wires plus the brush resistance in an electrical dc motor.
STEP 1: Convert Input(s) to Base Unit
Input Power: 78 Watt --> 78 Watt No Conversion Required
Armature Current: 0.724 Ampere --> 0.724 Ampere No Conversion Required
Armature Resistance: 80 Ohm --> 80 Ohm No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Pm = Pin-(Ia^2*Ra) --> 78-(0.724^2*80)
Evaluating ... ...
Pm = 36.06592
STEP 3: Convert Result to Output's Unit
36.06592 Watt --> No Conversion Required
FINAL ANSWER
36.06592 Watt <-- Mechanical Power
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Team Softusvista
Softusvista Office (Pune), India
Team Softusvista has verified this Calculator and 1100+ more calculators!

DC Motor Characteristics Calculators

Machine Construction Constant of DC Motor
​ Go Constant of Machine Construction = (Supply Voltage-Armature Current*Armature Resistance)/(Magnetic Flux*Motor Speed)
Back EMF Equation of DC Motor
​ Go Back EMF = (Number of Poles*Magnetic Flux*Number of Conductors*Motor Speed)/(60*Number of Parallel Paths)
Armature Current given Electrical Efficiency of DC Motor
​ Go Armature Current = (Angular Speed*Armature Torque)/(Supply Voltage*Electrical Efficiency)
Supply Voltage given Electrical Efficiency of DC Motor
​ Go Supply Voltage = (Angular Speed*Armature Torque)/(Armature Current*Electrical Efficiency)

Mechanical Power Developed in DC Motor given Input Power Formula

Mechanical Power = Input Power-(Armature Current^2*Armature Resistance)
Pm = Pin-(Ia^2*Ra)

What is input power?

Input Power is the power, which is required by the appliance at its input. The power input of a centrifugal pump (pump input power) is the mechanical power taken by the pump shaft or coupling from the drive.

How to Calculate Mechanical Power Developed in DC Motor given Input Power?

Mechanical Power Developed in DC Motor given Input Power calculator uses Mechanical Power = Input Power-(Armature Current^2*Armature Resistance) to calculate the Mechanical Power, Mechanical Power Developed in DC Motor given Input Power is defined as the mechanical power generated by an electrical machine when the input power is known. Mechanical Power is denoted by Pm symbol.

How to calculate Mechanical Power Developed in DC Motor given Input Power using this online calculator? To use this online calculator for Mechanical Power Developed in DC Motor given Input Power, enter Input Power (Pin), Armature Current (Ia) & Armature Resistance (Ra) and hit the calculate button. Here is how the Mechanical Power Developed in DC Motor given Input Power calculation can be explained with given input values -> -535.832 = 78-(0.724^2*80).

FAQ

What is Mechanical Power Developed in DC Motor given Input Power?
Mechanical Power Developed in DC Motor given Input Power is defined as the mechanical power generated by an electrical machine when the input power is known and is represented as Pm = Pin-(Ia^2*Ra) or Mechanical Power = Input Power-(Armature Current^2*Armature Resistance). Input Power is defined as the total power supplied to the electrical dc motor from the source which is connected to it, Armature Current DC motor is defined as the armature current developed in an electrical dc motor due to the rotation of rotor & The Armature Resistance is the ohmic resistance of the copper winding wires plus the brush resistance in an electrical dc motor.
How to calculate Mechanical Power Developed in DC Motor given Input Power?
Mechanical Power Developed in DC Motor given Input Power is defined as the mechanical power generated by an electrical machine when the input power is known is calculated using Mechanical Power = Input Power-(Armature Current^2*Armature Resistance). To calculate Mechanical Power Developed in DC Motor given Input Power, you need Input Power (Pin), Armature Current (Ia) & Armature Resistance (Ra). With our tool, you need to enter the respective value for Input Power, Armature Current & Armature Resistance and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!