Normalized Average Output Voltage Solution

STEP 0: Pre-Calculation Summary
Formula Used
Normalized Output Voltage 3 Phase Semi Converter = 0.5*(1+cos(Delay Angle of 3 Phase Semi Converter))
Vn(3Φ-semi) = 0.5*(1+cos(α(3Φ-semi)))
This formula uses 1 Functions, 2 Variables
Functions Used
cos - Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle., cos(Angle)
Variables Used
Normalized Output Voltage 3 Phase Semi Converter - Normalized Output Voltage 3 Phase Semi Converter is found be normalizing the average output voltage with maximum voltage in a semi converter based circuit.
Delay Angle of 3 Phase Semi Converter - (Measured in Radian) - Delay Angle of 3 Phase Semi Converter refers to the angle at which the thyristor is triggered to start conducting current in a 3 phase AC (alternating current) circuit.
STEP 1: Convert Input(s) to Base Unit
Delay Angle of 3 Phase Semi Converter: 70.3 Degree --> 1.22696646415178 Radian (Check conversion here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Vn(3Φ-semi) = 0.5*(1+cos(α(3Φ-semi))) --> 0.5*(1+cos(1.22696646415178))
Evaluating ... ...
Vn(3Φ-semi) = 0.668547629211651
STEP 3: Convert Result to Output's Unit
0.668547629211651 --> No Conversion Required
FINAL ANSWER
0.668547629211651 0.668548 <-- Normalized Output Voltage 3 Phase Semi Converter
(Calculation completed in 00.004 seconds)

Credits

Created by Devyaani Garg
Shiv Nadar University (SNU), Greater Noida
Devyaani Garg has created this Calculator and 50+ more calculators!
Verified by Nikita Suryawanshi
Vellore Institute of Technology (VIT), Vellore
Nikita Suryawanshi has verified this Calculator and 25+ more calculators!

4 Three Phase Semi-Converter Calculators

RMS Output Voltage for Three Phase Semi-Converter
Go RMS Output Voltage 3 Phase Semi Converter = sqrt(3)*Peak Input Voltage 3 Phase Semi Converter*((3/(4*pi))*(pi-Delay Angle of 3 Phase Semi Converter+((sin(2*Delay Angle of 3 Phase Semi Converter))/2))^0.5)
Average Output Voltage for Three Phase Semi-Converter
Go Average Voltage 3 Phase Semi Converter = (2.6*Peak Input Voltage 3 Phase Semi Converter*(1+cos(Delay Angle of 3 Phase Semi Converter)))/pi
Average Load Current of Three Phase Semi-Current
Go Load Current 3 Phase Semi Converter = Average Voltage 3 Phase Semi Converter/Resistance 3 Phase Semi Converter
Normalized Average Output Voltage
Go Normalized Output Voltage 3 Phase Semi Converter = 0.5*(1+cos(Delay Angle of 3 Phase Semi Converter))

Normalized Average Output Voltage Formula

Normalized Output Voltage 3 Phase Semi Converter = 0.5*(1+cos(Delay Angle of 3 Phase Semi Converter))
Vn(3Φ-semi) = 0.5*(1+cos(α(3Φ-semi)))

What is the normalization of voltage?

Normalized quantities are always the ratio of one quantity to other quantity. In the above formula, normalizing the average output voltage with respect to maximum load means finding the ratio of average output voltage to maximum voltage, i.e., Vdc/Vdm.

How to Calculate Normalized Average Output Voltage?

Normalized Average Output Voltage calculator uses Normalized Output Voltage 3 Phase Semi Converter = 0.5*(1+cos(Delay Angle of 3 Phase Semi Converter)) to calculate the Normalized Output Voltage 3 Phase Semi Converter, The Normalized average output voltage formula is found by normalizing the average output voltage to maximum voltage. Normalized Output Voltage 3 Phase Semi Converter is denoted by Vn(3Φ-semi) symbol.

How to calculate Normalized Average Output Voltage using this online calculator? To use this online calculator for Normalized Average Output Voltage, enter Delay Angle of 3 Phase Semi Converter (3Φ-semi)) and hit the calculate button. Here is how the Normalized Average Output Voltage calculation can be explained with given input values -> 0.668548 = 0.5*(1+cos(1.22696646415178)).

FAQ

What is Normalized Average Output Voltage?
The Normalized average output voltage formula is found by normalizing the average output voltage to maximum voltage and is represented as Vn(3Φ-semi) = 0.5*(1+cos(α(3Φ-semi))) or Normalized Output Voltage 3 Phase Semi Converter = 0.5*(1+cos(Delay Angle of 3 Phase Semi Converter)). Delay Angle of 3 Phase Semi Converter refers to the angle at which the thyristor is triggered to start conducting current in a 3 phase AC (alternating current) circuit.
How to calculate Normalized Average Output Voltage?
The Normalized average output voltage formula is found by normalizing the average output voltage to maximum voltage is calculated using Normalized Output Voltage 3 Phase Semi Converter = 0.5*(1+cos(Delay Angle of 3 Phase Semi Converter)). To calculate Normalized Average Output Voltage, you need Delay Angle of 3 Phase Semi Converter (3Φ-semi)). With our tool, you need to enter the respective value for Delay Angle of 3 Phase Semi Converter and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.