Overall Efficiency of DC Generator Solution

STEP 0: Pre-Calculation Summary
Formula Used
Overall Efficiency = Output Power/Input Power
ηo = Po/Pin
This formula uses 3 Variables
Variables Used
Overall Efficiency - Overall Efficiency is the ratio of useful output of a system to the total input applied to the system.
Output Power - (Measured in Watt) - Output Power refers to the product of current and voltage at the output terminal of a dc generator.
Input Power - (Measured in Watt) - Input Power refers to the power input required to rotate the armature of the generator, which in turn generates electrical power. The mechanical power is provided by an external source.
STEP 1: Convert Input(s) to Base Unit
Output Power: 120 Watt --> 120 Watt No Conversion Required
Input Power: 220 Watt --> 220 Watt No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
ηo = Po/Pin --> 120/220
Evaluating ... ...
ηo = 0.545454545454545
STEP 3: Convert Result to Output's Unit
0.545454545454545 --> No Conversion Required
FINAL ANSWER
0.545454545454545 0.545455 <-- Overall Efficiency
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Saiju Shah
Jayawantrao Sawant College of Engineering (JSCOE), Pune
Saiju Shah has created this Calculator and 4 more calculators!
Verifier Image
Verified by Swapneel Shah
Vidya Pratishthans College of Engineering (VPCOE), Baramati
Swapneel Shah has verified this Calculator and 5 more calculators!

17 DC Generator Characteristics Calculators

Mechanical Efficiency of DC Generator using Armature Voltage
​ Go Mechanical Efficiency = (Armature Voltage*Armature Current)/(Angular Speed*Torque)
EMF for DC Generator for Wave Winding
​ Go EMF = (Number of Poles*Rotor Speed*Flux per Pole*Number of Conductor)/120
Stray Losses of DC Generator given Converted Power
​ Go Stray Loss = Input Power-Mechanical Losses-Core Loss-Converted Power
Core Losses of DC Generator given Converted Power
​ Go Core Loss = Input Power-Mechanical Losses-Converted Power-Stray Loss
Armature Resistance of DC Generator using Output Voltage
​ Go Armature Resistance = (Armature Voltage-Output Voltage)/Armature Current
EMF for DC Generator with Lap Winding
​ Go EMF = (Rotor Speed*Flux per Pole*Number of Conductor)/60
Back EMF of DC Generator given Flux
​ Go EMF = Back EMF Constant*Angular Speed*Flux per Pole
Power Drop in Brush DC Generator
​ Go Brush Power Drop = Armature Current*Brush Voltage Drop
Electrical Efficiency of DC Generator
​ Go Electrical Efficiency = Output Power/Converted Power
Induced Armature Voltage of DC Generator given Converted Power
​ Go Armature Voltage = Converted Power/Armature Current
Mechanical Efficiency of DC Generator using Converted Power
​ Go Mechanical Efficiency = Converted Power/Input Power
Armature Current of DC Generator given Power
​ Go Armature Current = Converted Power/Armature Voltage
Armature Power in DC Generator
​ Go Amature Power = Armature Voltage*Armature Current
Field Copper Loss in DC Generator
​ Go Copper Loss = Field Current^2*Field Resistance
Output Voltage in DC Generator using Converted Power
​ Go Output Voltage = Converted Power/Load Current
Overall Efficiency of DC Generator
​ Go Overall Efficiency = Output Power/Input Power
Converted Power in DC Generator
​ Go Converted Power = Output Voltage*Load Current

Overall Efficiency of DC Generator Formula

Overall Efficiency = Output Power/Input Power
ηo = Po/Pin

What is the Overall Efficiency of DC Generator?

The Overall Efficiency of DC Generator is ratio of output power to input mechanical power. The value of overall efficiency of DC generator ranges from 85% to 95%.

How to Calculate Overall Efficiency of DC Generator?

Overall Efficiency of DC Generator calculator uses Overall Efficiency = Output Power/Input Power to calculate the Overall Efficiency, The Overall Efficiency of DC Generator is the ratio of output power to input mechanical power. Overall Efficiency is denoted by ηo symbol.

How to calculate Overall Efficiency of DC Generator using this online calculator? To use this online calculator for Overall Efficiency of DC Generator, enter Output Power (Po) & Input Power (Pin) and hit the calculate button. Here is how the Overall Efficiency of DC Generator calculation can be explained with given input values -> 0.545455 = 120/220.

FAQ

What is Overall Efficiency of DC Generator?
The Overall Efficiency of DC Generator is the ratio of output power to input mechanical power and is represented as ηo = Po/Pin or Overall Efficiency = Output Power/Input Power. Output Power refers to the product of current and voltage at the output terminal of a dc generator & Input Power refers to the power input required to rotate the armature of the generator, which in turn generates electrical power. The mechanical power is provided by an external source.
How to calculate Overall Efficiency of DC Generator?
The Overall Efficiency of DC Generator is the ratio of output power to input mechanical power is calculated using Overall Efficiency = Output Power/Input Power. To calculate Overall Efficiency of DC Generator, you need Output Power (Po) & Input Power (Pin). With our tool, you need to enter the respective value for Output Power & Input Power and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!