Porosity of Soil given Infiltration Capacity from Green-Ampt Equation Solution

STEP 0: Pre-Calculation Summary
Formula Used
Porosity = (Infiltration Capacity at Any Time t/Darcy's Hydraulic Conductivity-1)*Cumulative Infiltration Capacity/Capillary Suction at Wetting Front
η = (fp/K-1)*Fp/Sc
This formula uses 5 Variables
Variables Used
Porosity - Porosity is the ratio of volume of voids to volume of soil.
Infiltration Capacity at Any Time t - (Measured in Centimeter per Hour) - Infiltration Capacity at Any Time t from the start of the rainfall is the rate at which water percolates in the soil.
Darcy's Hydraulic Conductivity - (Measured in Centimeter per Hour) - Darcy's Hydraulic Conductivity measures soil's ability to transmit water, vital in understanding groundwater flow and environmental processes.
Cumulative Infiltration Capacity - (Measured in Centimeter per Hour) - Cumulative Infiltration Capacity is calculated by subtracting the cumulative runoff from the cumulative rainfall.
Capillary Suction at Wetting Front - Capillary Suction at Wetting Front is due to capillary attraction in the soil voids and is large for fine grained soils such as clays and small for sandy soils.
STEP 1: Convert Input(s) to Base Unit
Infiltration Capacity at Any Time t: 16 Centimeter per Hour --> 16 Centimeter per Hour No Conversion Required
Darcy's Hydraulic Conductivity: 13 Centimeter per Hour --> 13 Centimeter per Hour No Conversion Required
Cumulative Infiltration Capacity: 20 Centimeter per Hour --> 20 Centimeter per Hour No Conversion Required
Capillary Suction at Wetting Front: 6 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
η = (fp/K-1)*Fp/Sc --> (16/13-1)*20/6
Evaluating ... ...
η = 0.769230769230769
STEP 3: Convert Result to Output's Unit
0.769230769230769 --> No Conversion Required
FINAL ANSWER
0.769230769230769 0.769231 <-- Porosity
(Calculation completed in 00.004 seconds)

Credits

Created by Mithila Muthamma PA
Coorg Institute of Technology (CIT), Coorg
Mithila Muthamma PA has created this Calculator and 2000+ more calculators!
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

6 Green-Ampt Equation (1911) Calculators

Darcy's Hydraulic Conductivity given Infiltration Capacity from Green-Ampt Equation
Go Darcy's Hydraulic Conductivity = Infiltration Capacity at Any Time t/(1+(Porosity*Capillary Suction at Wetting Front)/Cumulative Infiltration Capacity)
Green Ampt Equation
Go Infiltration Capacity at Any Time t = Darcy's Hydraulic Conductivity*(1+(Porosity*Capillary Suction at Wetting Front)/Cumulative Infiltration Capacity)
Porosity of Soil given Infiltration Capacity from Green-Ampt Equation
Go Porosity = (Infiltration Capacity at Any Time t/Darcy's Hydraulic Conductivity-1)*Cumulative Infiltration Capacity/Capillary Suction at Wetting Front
Capillary Suction given Infiltration Capacity
Go Capillary Suction at Wetting Front = (Infiltration Capacity at Any Time t/Darcy's Hydraulic Conductivity-1)*Cumulative Infiltration Capacity/Porosity
Cumulative Infiltration Capacity given Green-Ampt Parameters of Infiltration Model
Go Cumulative Infiltration Capacity = Parameter 'n' of Infiltration Model by Green-Ampt/(Infiltration Capacity at Any Time t-Parameter 'm' of Infiltration Model by Green-Ampt)
Infiltration Capacity given Green-Ampt Parameters of Infiltration Model
Go Infiltration Capacity at Any Time t = Parameter 'm' of Infiltration Model by Green-Ampt+Parameter 'n' of Infiltration Model by Green-Ampt/Cumulative Infiltration Capacity

Porosity of Soil given Infiltration Capacity from Green-Ampt Equation Formula

Porosity = (Infiltration Capacity at Any Time t/Darcy's Hydraulic Conductivity-1)*Cumulative Infiltration Capacity/Capillary Suction at Wetting Front
η = (fp/K-1)*Fp/Sc

What is Green Ampt equation?

The Basic assumption behind the Green and Ampt equation is that water infiltrates into (relatively) dry soil as a sharp wetting front. The passage of this front causes the moisture content to increase from an initial value to a saturated value.

What is Infiltration Capacity?

The Infiltration Capacity is defined as the maximum rate of infiltration. It is most often measured in meters per day but can also be measured in other units of distance over time if necessary. The infiltration capacity decreases as the soil moisture content of soil surface layers increases.

How to Calculate Porosity of Soil given Infiltration Capacity from Green-Ampt Equation?

Porosity of Soil given Infiltration Capacity from Green-Ampt Equation calculator uses Porosity = (Infiltration Capacity at Any Time t/Darcy's Hydraulic Conductivity-1)*Cumulative Infiltration Capacity/Capillary Suction at Wetting Front to calculate the Porosity, The Porosity of Soil given Infiltration Capacity from Green-Ampt Equation formula is defined as the porosity or void fraction is a measure of the void spaces in a material and is a fraction of the volume of voids over the total volume, between 0 and 1, or as a percentage. Porosity is denoted by η symbol.

How to calculate Porosity of Soil given Infiltration Capacity from Green-Ampt Equation using this online calculator? To use this online calculator for Porosity of Soil given Infiltration Capacity from Green-Ampt Equation, enter Infiltration Capacity at Any Time t (fp), Darcy's Hydraulic Conductivity (K), Cumulative Infiltration Capacity (Fp) & Capillary Suction at Wetting Front (Sc) and hit the calculate button. Here is how the Porosity of Soil given Infiltration Capacity from Green-Ampt Equation calculation can be explained with given input values -> 14.86917 = (4.44444444444444E-05/3.61111111111111E-05-1)*5.55555555555556E-05/6.

FAQ

What is Porosity of Soil given Infiltration Capacity from Green-Ampt Equation?
The Porosity of Soil given Infiltration Capacity from Green-Ampt Equation formula is defined as the porosity or void fraction is a measure of the void spaces in a material and is a fraction of the volume of voids over the total volume, between 0 and 1, or as a percentage and is represented as η = (fp/K-1)*Fp/Sc or Porosity = (Infiltration Capacity at Any Time t/Darcy's Hydraulic Conductivity-1)*Cumulative Infiltration Capacity/Capillary Suction at Wetting Front. Infiltration Capacity at Any Time t from the start of the rainfall is the rate at which water percolates in the soil, Darcy's Hydraulic Conductivity measures soil's ability to transmit water, vital in understanding groundwater flow and environmental processes, Cumulative Infiltration Capacity is calculated by subtracting the cumulative runoff from the cumulative rainfall & Capillary Suction at Wetting Front is due to capillary attraction in the soil voids and is large for fine grained soils such as clays and small for sandy soils.
How to calculate Porosity of Soil given Infiltration Capacity from Green-Ampt Equation?
The Porosity of Soil given Infiltration Capacity from Green-Ampt Equation formula is defined as the porosity or void fraction is a measure of the void spaces in a material and is a fraction of the volume of voids over the total volume, between 0 and 1, or as a percentage is calculated using Porosity = (Infiltration Capacity at Any Time t/Darcy's Hydraulic Conductivity-1)*Cumulative Infiltration Capacity/Capillary Suction at Wetting Front. To calculate Porosity of Soil given Infiltration Capacity from Green-Ampt Equation, you need Infiltration Capacity at Any Time t (fp), Darcy's Hydraulic Conductivity (K), Cumulative Infiltration Capacity (Fp) & Capillary Suction at Wetting Front (Sc). With our tool, you need to enter the respective value for Infiltration Capacity at Any Time t, Darcy's Hydraulic Conductivity, Cumulative Infiltration Capacity & Capillary Suction at Wetting Front and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!