Position Smoothing Parameter Solution

STEP 0: Pre-Calculation Summary
Formula Used
Position Smoothing Parameter = (Smoothed Position-Target Predicted Position)/(Measured Position at Nth Scan-Target Predicted Position)
α = (Xin-xpn)/(xn-xpn)
This formula uses 4 Variables
Variables Used
Position Smoothing Parameter - Position Smoothing Parameter is the tuning parameter which is used to improve the quality of smoothed position estimated by the track-while-scan surveillance radar to avoid noisy measurements.
Smoothed Position - (Measured in Meter) - Smoothed Position is defined as the estimated present position of target by track-while-scan surveillance radar.
Target Predicted Position - (Measured in Meter) - Target Predicted Position is the predicted or estimated position of target at the nth scan by the track-while-scan surveillance radar.
Measured Position at Nth Scan - (Measured in Meter) - Measured position at Nth scan is the measured or actual position of target at the nth scan by the track-while-scan surveillance radar.
STEP 1: Convert Input(s) to Base Unit
Smoothed Position: 40 Meter --> 40 Meter No Conversion Required
Target Predicted Position: 74 Meter --> 74 Meter No Conversion Required
Measured Position at Nth Scan: 6 Meter --> 6 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
α = (Xin-xpn)/(xn-xpn) --> (40-74)/(6-74)
Evaluating ... ...
α = 0.5
STEP 3: Convert Result to Output's Unit
0.5 --> No Conversion Required
FINAL ANSWER
0.5 <-- Position Smoothing Parameter
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Shobhit Dimri
Bipin Tripathi Kumaon Institute of Technology (BTKIT), Dwarahat
Shobhit Dimri has created this Calculator and 900+ more calculators!
Verifier Image
Verified by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has verified this Calculator and 1900+ more calculators!

21 Special Purpose Radars Calculators

Amplitude of Signal Received from Target at Range
​ Go Amplitude of Signal Received = Echo Signal Voltage/(sin((2*pi*(Carrier Frequency+Doppler Frequency Shift)*Time Period)-((4*pi*Carrier Frequency*Range)/[c])))
Echo Signal Voltage
​ Go Echo Signal Voltage = Amplitude of Signal Received*sin((2*pi*(Carrier Frequency+Doppler Frequency Shift)*Time Period)-((4*pi*Carrier Frequency*Range)/[c]))
Velocity Smoothing Parameter
​ Go Velocity Smoothing Parameter = ((Smoothed Velocity-(n-1)th Scan Smoothed Velocity)/(Measured Position at Nth Scan-Target Predicted Position))*Time between Observations
Time between Observations
​ Go Time between Observations = (Velocity Smoothing Parameter/(Smoothed Velocity-(n-1)th Scan Smoothed Velocity))*(Measured Position at Nth Scan-Target Predicted Position)
Smoothed Velocity
​ Go Smoothed Velocity = (n-1)th Scan Smoothed Velocity+Velocity Smoothing Parameter/Time between Observations*(Measured Position at Nth Scan-Target Predicted Position)
Phase Difference between Echo Signals in Monopulse Radar
​ Go Phase Difference between Echo Signals = 2*pi*Distance between Antennas in Monopulse Radar*sin(Angle in Monopulse Radar)/Wavelength
Predicted Position of Target
​ Go Target Predicted Position = (Smoothed Position-(Position Smoothing Parameter*Measured Position at Nth Scan))/(1-Position Smoothing Parameter)
Amplitude of Reference Signal
​ Go Amplitude of Reference Signal = CW Oscillator Reference Voltage/(sin(2*pi*Angular Frequency*Time Period))
Reference Voltage of CW Oscillator
​ Go CW Oscillator Reference Voltage = Amplitude of Reference Signal*sin(2*pi*Angular Frequency*Time Period)
Measured Position at Nth Scan
​ Go Measured Position at Nth Scan = ((Smoothed Position-Target Predicted Position)/Position Smoothing Parameter)+Target Predicted Position
Position Smoothing Parameter
​ Go Position Smoothing Parameter = (Smoothed Position-Target Predicted Position)/(Measured Position at Nth Scan-Target Predicted Position)
Smoothed Position
​ Go Smoothed Position = Target Predicted Position+Position Smoothing Parameter*(Measured Position at Nth Scan-Target Predicted Position)
Distance from Antenna 1 to Target in Monopulse Radar
​ Go Distance from Antenna 1 to Target = (Range+Distance between Antennas in Monopulse Radar)/2*sin(Angle in Monopulse Radar)
Distance from Antenna 2 to Target in Monopulse Radar
​ Go Distance from Antenna 2 to Target = (Range-Distance between Antennas in Monopulse Radar)/2*sin(Angle in Monopulse Radar)
Efficiency of Cross Field Amplifier(CFA)
​ Go Efficiency of Cross Field Amplifier = (CFA RF Power Output-CFA RF Drive Power)/DC Power Input
CFA DC Power Input
​ Go DC Power Input = (CFA RF Power Output-CFA RF Drive Power)/Efficiency of Cross Field Amplifier
CFA RF Power Output
​ Go CFA RF Power Output = Efficiency of Cross Field Amplifier*DC Power Input+CFA RF Drive Power
CFA RF Drive Power
​ Go CFA RF Drive Power = CFA RF Power Output-Efficiency of Cross Field Amplifier*DC Power Input
Range Resolution
​ Go Range Resolution = (2*Antenna Height*Target Height)/Range
Doppler Frequency Shift
​ Go Doppler Frequency Shift = (2*Target Velocity)/Wavelength
Peak Quantization Lobe
​ Go Peak Quantization Lobe = 1/2^(2*Mean Lobe)

Position Smoothing Parameter Formula

Position Smoothing Parameter = (Smoothed Position-Target Predicted Position)/(Measured Position at Nth Scan-Target Predicted Position)
α = (Xin-xpn)/(xn-xpn)

What is smooth positioning solution?

A smooth positioning solution refers to GPS/GNSS data that has been run through a special filter or algorithm to create a smooth trajectory without any sudden position jumps due to changing GNSS signal conditions.

How to Calculate Position Smoothing Parameter?

Position Smoothing Parameter calculator uses Position Smoothing Parameter = (Smoothed Position-Target Predicted Position)/(Measured Position at Nth Scan-Target Predicted Position) to calculate the Position Smoothing Parameter, The Position Smoothing parameter formula is used to calculate the tuning parameter which is used to improve the quality of smoothed position estimated by the track-while-scan surveillance radar to avoid noisy measurements due to factors like clutters or noise in radar system. Position Smoothing Parameter is denoted by α symbol.

How to calculate Position Smoothing Parameter using this online calculator? To use this online calculator for Position Smoothing Parameter, enter Smoothed Position (Xin), Target Predicted Position (xpn) & Measured Position at Nth Scan (xn) and hit the calculate button. Here is how the Position Smoothing Parameter calculation can be explained with given input values -> 0.5 = (40-74)/(6-74).

FAQ

What is Position Smoothing Parameter?
The Position Smoothing parameter formula is used to calculate the tuning parameter which is used to improve the quality of smoothed position estimated by the track-while-scan surveillance radar to avoid noisy measurements due to factors like clutters or noise in radar system and is represented as α = (Xin-xpn)/(xn-xpn) or Position Smoothing Parameter = (Smoothed Position-Target Predicted Position)/(Measured Position at Nth Scan-Target Predicted Position). Smoothed Position is defined as the estimated present position of target by track-while-scan surveillance radar, Target Predicted Position is the predicted or estimated position of target at the nth scan by the track-while-scan surveillance radar & Measured position at Nth scan is the measured or actual position of target at the nth scan by the track-while-scan surveillance radar.
How to calculate Position Smoothing Parameter?
The Position Smoothing parameter formula is used to calculate the tuning parameter which is used to improve the quality of smoothed position estimated by the track-while-scan surveillance radar to avoid noisy measurements due to factors like clutters or noise in radar system is calculated using Position Smoothing Parameter = (Smoothed Position-Target Predicted Position)/(Measured Position at Nth Scan-Target Predicted Position). To calculate Position Smoothing Parameter, you need Smoothed Position (Xin), Target Predicted Position (xpn) & Measured Position at Nth Scan (xn). With our tool, you need to enter the respective value for Smoothed Position, Target Predicted Position & Measured Position at Nth Scan and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!