Positive Sequence Current using Positive Sequence Voltage (Two Conductor Open) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Positive Sequence Current in TCO = (A Phase EMF in TCO-Positive Sequence Voltage in TCO)/Positive Sequence Impedance in TCO
I1(tco) = (Ea(tco)-V1(tco))/Z1(tco)
This formula uses 4 Variables
Variables Used
Positive Sequence Current in TCO - (Measured in Ampere) - Positive Sequence Current in TCO is consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation.
A Phase EMF in TCO - (Measured in Volt) - A Phase EMF in TCO is defined as the electromagnetic force of the a-phase in open conductor fault.
Positive Sequence Voltage in TCO - (Measured in Volt) - Positive Sequence Voltage in TCO is consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation.
Positive Sequence Impedance in TCO - (Measured in Ohm) - Positive Sequence Impedance in TCO is consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation.
STEP 1: Convert Input(s) to Base Unit
A Phase EMF in TCO: 121.38 Volt --> 121.38 Volt No Conversion Required
Positive Sequence Voltage in TCO: 105 Volt --> 105 Volt No Conversion Required
Positive Sequence Impedance in TCO: 7.95 Ohm --> 7.95 Ohm No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
I1(tco) = (Ea(tco)-V1(tco))/Z1(tco) --> (121.38-105)/7.95
Evaluating ... ...
I1(tco) = 2.06037735849057
STEP 3: Convert Result to Output's Unit
2.06037735849057 Ampere --> No Conversion Required
FINAL ANSWER
2.06037735849057 2.060377 Ampere <-- Positive Sequence Current in TCO
(Calculation completed in 00.020 seconds)

Credits

Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verified by Payal Priya
Birsa Institute of Technology (BIT), Sindri
Payal Priya has verified this Calculator and 1900+ more calculators!

7 Positive Sequence Calculators

Positive Sequence Impedance using A-Phase EMF (Two Conductor Open)
Go Positive Sequence Impedance in TCO = (A Phase EMF in TCO/Positive Sequence Current in TCO)-Zero Sequence Impedance in TCO-Negative Sequence Impedance in TCO
Positive Sequence Current using A-Phase EMF (Two Conductor Open)
Go Positive Sequence Current in TCO = A Phase EMF in TCO/(Zero Sequence Impedance in TCO+Positive Sequence Impedance in TCO+Negative Sequence Impedance in TCO)
Positive Sequence Impedance using Positive Sequence Voltage (Two Conductor Open)
Go Positive Sequence Impedance in TCO = (A Phase EMF in TCO-Positive Sequence Voltage in TCO)/Positive Sequence Current in TCO
Positive Sequence Current using Positive Sequence Voltage (Two Conductor Open)
Go Positive Sequence Current in TCO = (A Phase EMF in TCO-Positive Sequence Voltage in TCO)/Positive Sequence Impedance in TCO
Positive Sequence Voltage using Positive Sequence Current (Two Conductor Open)
Go Positive Sequence Voltage in TCO = A Phase EMF in TCO-Positive Sequence Current in TCO*Positive Sequence Impedance in TCO
Positive Sequence Potential Difference (Two Conductor Open)
Go Positive Sequence Potential Difference in TCO = ((-1)*Negative Sequence Potential Difference in TCO)-Zero Sequence Potential Difference in TCO
Positive Sequence Current (Two Conductor Open)
Go Positive Sequence Current in TCO = A-Phase Current in TCO/3

Positive Sequence Current using Positive Sequence Voltage (Two Conductor Open) Formula

Positive Sequence Current in TCO = (A Phase EMF in TCO-Positive Sequence Voltage in TCO)/Positive Sequence Impedance in TCO
I1(tco) = (Ea(tco)-V1(tco))/Z1(tco)

What is two open conductor fault?

When two phases of a balanced three-phase line open it creates an unbalance in the system and results in the flow of unbalanced currents. Such conditions occur in the system when one or two conductors of a transmission line are broken due to storms or if fuses, isolators, or circuit breakers operate only on one or two phases leaving others connected.

How to Calculate Positive Sequence Current using Positive Sequence Voltage (Two Conductor Open)?

Positive Sequence Current using Positive Sequence Voltage (Two Conductor Open) calculator uses Positive Sequence Current in TCO = (A Phase EMF in TCO-Positive Sequence Voltage in TCO)/Positive Sequence Impedance in TCO to calculate the Positive Sequence Current in TCO, The Positive Sequence Current using Positive Sequence Voltage (Two conductor open) formula is consists of balanced three-phase current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation. Positive Sequence Current in TCO is denoted by I1(tco) symbol.

How to calculate Positive Sequence Current using Positive Sequence Voltage (Two Conductor Open) using this online calculator? To use this online calculator for Positive Sequence Current using Positive Sequence Voltage (Two Conductor Open), enter A Phase EMF in TCO (Ea(tco)), Positive Sequence Voltage in TCO (V1(tco)) & Positive Sequence Impedance in TCO (Z1(tco)) and hit the calculate button. Here is how the Positive Sequence Current using Positive Sequence Voltage (Two Conductor Open) calculation can be explained with given input values -> 7.720755 = (121.38-105)/7.95.

FAQ

What is Positive Sequence Current using Positive Sequence Voltage (Two Conductor Open)?
The Positive Sequence Current using Positive Sequence Voltage (Two conductor open) formula is consists of balanced three-phase current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation and is represented as I1(tco) = (Ea(tco)-V1(tco))/Z1(tco) or Positive Sequence Current in TCO = (A Phase EMF in TCO-Positive Sequence Voltage in TCO)/Positive Sequence Impedance in TCO. A Phase EMF in TCO is defined as the electromagnetic force of the a-phase in open conductor fault, Positive Sequence Voltage in TCO is consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation & Positive Sequence Impedance in TCO is consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation.
How to calculate Positive Sequence Current using Positive Sequence Voltage (Two Conductor Open)?
The Positive Sequence Current using Positive Sequence Voltage (Two conductor open) formula is consists of balanced three-phase current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation is calculated using Positive Sequence Current in TCO = (A Phase EMF in TCO-Positive Sequence Voltage in TCO)/Positive Sequence Impedance in TCO. To calculate Positive Sequence Current using Positive Sequence Voltage (Two Conductor Open), you need A Phase EMF in TCO (Ea(tco)), Positive Sequence Voltage in TCO (V1(tco)) & Positive Sequence Impedance in TCO (Z1(tco)). With our tool, you need to enter the respective value for A Phase EMF in TCO, Positive Sequence Voltage in TCO & Positive Sequence Impedance in TCO and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Positive Sequence Current in TCO?
In this formula, Positive Sequence Current in TCO uses A Phase EMF in TCO, Positive Sequence Voltage in TCO & Positive Sequence Impedance in TCO. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Positive Sequence Current in TCO = A-Phase Current in TCO/3
  • Positive Sequence Current in TCO = A Phase EMF in TCO/(Zero Sequence Impedance in TCO+Positive Sequence Impedance in TCO+Negative Sequence Impedance in TCO)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!