Power Output from Generator Solution

STEP 0: Pre-Calculation Summary
Formula Used
Power Output = Output Voltage*(Cathode Current Density-Anode Current Density)
Pout = Vout*(Jc-Ja)
This formula uses 4 Variables
Variables Used
Power Output - (Measured in Watt per Square Meter) - Power output refers to the rate at which energy is produced, transferred, or converted into useful work or other forms of energy over a specified period of time.
Output Voltage - (Measured in Volt) - Output Voltage is the net potential difference. Output voltage refers to the electrical potential difference between the positive and negative terminals of a device or circuit.
Cathode Current Density - (Measured in Ampere per Square Meter) - Cathode Current Density is a measure of the flow of electric charge through a given area of a conductor from Cathode.
Anode Current Density - (Measured in Ampere per Square Meter) - Anode Current Density is a measure of the flow of electric charge through a given area of a conductor from Anode.
STEP 1: Convert Input(s) to Base Unit
Output Voltage: 0.27 Volt --> 0.27 Volt No Conversion Required
Cathode Current Density: 0.47 Ampere per Square Centimeter --> 4700 Ampere per Square Meter (Check conversion ​here)
Anode Current Density: 0.26 Ampere per Square Centimeter --> 2600 Ampere per Square Meter (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Pout = Vout*(Jc-Ja) --> 0.27*(4700-2600)
Evaluating ... ...
Pout = 567
STEP 3: Convert Result to Output's Unit
567 Watt per Square Meter -->0.0567 Watt per Square Centimeter (Check conversion ​here)
FINAL ANSWER
0.0567 Watt per Square Centimeter <-- Power Output
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Nisarg
Indian Institute of Technology,Roorlee (IITR), Roorkee
Nisarg has created this Calculator and 100+ more calculators!
Verifier Image
Verified by Parminder Singh
Chandigarh University (CU), Punjab
Parminder Singh has verified this Calculator and 600+ more calculators!

12 Thermal Power Plant Calculators

Current Density from Cathode to Anode
​ Go Cathode Current Density = Emission Constant*Cathode Temperature^2*exp(-([Charge-e]*Cathode Voltage)/([BoltZ]*Cathode Temperature))
Maximum Electron Current per Unit Area
​ Go Current Density = Emission Constant*Temperature^2*exp(-Work Function/([BoltZ]*Temperature))
Net Kinetic Energy of Electron
​ Go Electron Net Energy = Cathode Current Density*((2*[BoltZ]*Cathode Temperature)/[Charge-e])
Output Voltage given Fermi Energy Levels
​ Go Output Voltage = (Anode Fermi Energy Level-Cathode Fermi Energy Level)/[Charge-e]
Power Output from Generator
​ Go Power Output = Output Voltage*(Cathode Current Density-Anode Current Density)
Consumption of Coal per Hour
​ Go Consumption of Coal per Hour = Heat Input per Hour/Calorific Value of Coal
Overall Efficiency of Power Station
​ Go Overall Efficiency = Thermal Efficiency*Electrical Efficiency
Thermal Efficiency of Power Station
​ Go Thermal Efficiency = Overall Efficiency/Electrical Efficiency
Output Voltage given Anode and Cathode Work Functions
​ Go Output Voltage = Cathode Work Function-Anode Work Function
Rankine Cycle Efficiency
​ Go Rankine Cycle Efficiency = Net Work Output/Heat Supplied
Minimum Energy required by Electron to Leave Cathode
​ Go Net Energy = Cathode Current Density*Cathode Voltage
Output Voltage given Anode and Cathode Voltages
​ Go Output Voltage = Cathode Voltage-Anode Voltage

Power Output from Generator Formula

Power Output = Output Voltage*(Cathode Current Density-Anode Current Density)
Pout = Vout*(Jc-Ja)

What is the maximum power output of thermionic generator?

A single TEG generates power from 1 to 125 W. The use of more TEGs in a modular connection may increase the power up to 5 kW and Δ T max could be bigger than 70°C. Heat source , for example, a heat pipe system (the TEG devices and the heat pipe system can be used together in waste heat recovery systems).

How to Calculate Power Output from Generator?

Power Output from Generator calculator uses Power Output = Output Voltage*(Cathode Current Density-Anode Current Density) to calculate the Power Output, The Power Output from Generator formula is defined as the power generated by generator due to the potential difference. Power Output is denoted by Pout symbol.

How to calculate Power Output from Generator using this online calculator? To use this online calculator for Power Output from Generator, enter Output Voltage (Vout), Cathode Current Density (Jc) & Anode Current Density (Ja) and hit the calculate button. Here is how the Power Output from Generator calculation can be explained with given input values -> 5.7E-6 = 0.27*(4700-2600).

FAQ

What is Power Output from Generator?
The Power Output from Generator formula is defined as the power generated by generator due to the potential difference and is represented as Pout = Vout*(Jc-Ja) or Power Output = Output Voltage*(Cathode Current Density-Anode Current Density). Output Voltage is the net potential difference. Output voltage refers to the electrical potential difference between the positive and negative terminals of a device or circuit, Cathode Current Density is a measure of the flow of electric charge through a given area of a conductor from Cathode & Anode Current Density is a measure of the flow of electric charge through a given area of a conductor from Anode.
How to calculate Power Output from Generator?
The Power Output from Generator formula is defined as the power generated by generator due to the potential difference is calculated using Power Output = Output Voltage*(Cathode Current Density-Anode Current Density). To calculate Power Output from Generator, you need Output Voltage (Vout), Cathode Current Density (Jc) & Anode Current Density (Ja). With our tool, you need to enter the respective value for Output Voltage, Cathode Current Density & Anode Current Density and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!