Power Transmitted Per Phase (3 Phase 3 Wire US) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Power Transmitted per Phase = Power Transmitted/3
Pt = P/3
This formula uses 2 Variables
Variables Used
Power Transmitted per Phase - (Measured in Watt) - Power Transmitted per Phase is defined as the power delivered to a single phase in a poly-phase electrical network.
Power Transmitted - (Measured in Watt) - Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work.
STEP 1: Convert Input(s) to Base Unit
Power Transmitted: 300 Watt --> 300 Watt No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Pt = P/3 --> 300/3
Evaluating ... ...
Pt = 100
STEP 3: Convert Result to Output's Unit
100 Watt --> No Conversion Required
FINAL ANSWER
100 Watt <-- Power Transmitted per Phase
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

8 Power & Power Factor Calculators

Power Transmitted using Area of X-Section (3 Phase 3 Wire US)
​ Go Power Transmitted = sqrt(Area of Underground AC Wire*Line Losses*(Maximum Voltage Underground AC^2)*(cos(Phase Difference)^2)/(2*Resistivity*Length of Underground AC Wire))
Power Transmitted using Volume of Conductor Material (3 Phase 3 Wire US)
​ Go Power Transmitted = sqrt(Line Losses*Volume Of Conductor*(Maximum Voltage Underground AC*cos(Phase Difference))^2/(6*Resistivity*(Length of Underground AC Wire)^2))
Power Factor using Area of X-Section (3 Phase 3 Wire US)
​ Go Power Factor = (Power Transmitted/Maximum Voltage Underground AC)*sqrt(2*Resistivity*Length of Underground AC Wire/(Area of Underground AC Wire))
Power Transmitted using Load Current Per Phase (3 Phase 3 Wire US)
​ Go Power Transmitted = Current Underground AC*3*Maximum Voltage Underground AC*cos(Phase Difference)/sqrt(6)
Power Factor Angle for 3 Phase 3 Wire System
​ Go Phase Difference = acos(Power Transmitted/(sqrt(3)*Voltage Underground AC*Current Underground AC))
Power Factor using Load Current Per Phase (3 Phase 3 Wire US)
​ Go Power Factor = sqrt(6)*Power Transmitted/(Current Underground AC*Maximum Voltage Underground AC*3)
Power Factor using Volume of Conductor Material (3 Phase 3 Wire US)
​ Go Power Factor = sqrt((1.5)*Constant Underground AC/Volume Of Conductor)
Power Transmitted Per Phase (3 Phase 3 Wire US)
​ Go Power Transmitted per Phase = Power Transmitted/3

Power Transmitted Per Phase (3 Phase 3 Wire US) Formula

Power Transmitted per Phase = Power Transmitted/3
Pt = P/3

What is the value of volume of conductor material in 3-phase 3-wire US?

The maximum voltage between conductors is vm/√3 so that r.m.s. value of voltage between them is vm/√6.

How to Calculate Power Transmitted Per Phase (3 Phase 3 Wire US)?

Power Transmitted Per Phase (3 Phase 3 Wire US) calculator uses Power Transmitted per Phase = Power Transmitted/3 to calculate the Power Transmitted per Phase, The Power Transmitted per Phase (3 phase 3 wire US) formula is defined as the bulk movement of electrical energy from a generating site, such as a power station or power plant, to an electrical substation where voltage is transformed and distributed to consumers or other substations. Power Transmitted per Phase is denoted by Pt symbol.

How to calculate Power Transmitted Per Phase (3 Phase 3 Wire US) using this online calculator? To use this online calculator for Power Transmitted Per Phase (3 Phase 3 Wire US), enter Power Transmitted (P) and hit the calculate button. Here is how the Power Transmitted Per Phase (3 Phase 3 Wire US) calculation can be explained with given input values -> 100 = 300/3.

FAQ

What is Power Transmitted Per Phase (3 Phase 3 Wire US)?
The Power Transmitted per Phase (3 phase 3 wire US) formula is defined as the bulk movement of electrical energy from a generating site, such as a power station or power plant, to an electrical substation where voltage is transformed and distributed to consumers or other substations and is represented as Pt = P/3 or Power Transmitted per Phase = Power Transmitted/3. Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work.
How to calculate Power Transmitted Per Phase (3 Phase 3 Wire US)?
The Power Transmitted per Phase (3 phase 3 wire US) formula is defined as the bulk movement of electrical energy from a generating site, such as a power station or power plant, to an electrical substation where voltage is transformed and distributed to consumers or other substations is calculated using Power Transmitted per Phase = Power Transmitted/3. To calculate Power Transmitted Per Phase (3 Phase 3 Wire US), you need Power Transmitted (P). With our tool, you need to enter the respective value for Power Transmitted and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!