Power Transmitted using V Belt Solution

STEP 0: Pre-Calculation Summary
Formula Used
Power transmitted by belt = (Belt Tension on Tight Side-Belt Tension on Loose Side)*Belt Velocity
Pt = (P1-P2)*vb
This formula uses 4 Variables
Variables Used
Power transmitted by belt - (Measured in Watt) - Power transmitted by belt is the amount of power that is transmitted from the belt of a belt drive to the pulley.
Belt Tension on Tight Side - (Measured in Newton) - Belt Tension on Tight Side is defined as the belt's tension on the belt's tight side.
Belt Tension on Loose Side - (Measured in Newton) - Belt Tension on Loose Side is defined as the belt's tension on the belt's loose side.
Belt Velocity - (Measured in Meter per Second) - Belt Velocity is defined as the velocity of the belt used in a belt drive.
STEP 1: Convert Input(s) to Base Unit
Belt Tension on Tight Side: 800 Newton --> 800 Newton No Conversion Required
Belt Tension on Loose Side: 550 Newton --> 550 Newton No Conversion Required
Belt Velocity: 25.81 Meter per Second --> 25.81 Meter per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Pt = (P1-P2)*vb --> (800-550)*25.81
Evaluating ... ...
Pt = 6452.5
STEP 3: Convert Result to Output's Unit
6452.5 Watt -->6.4525 Kilowatt (Check conversion here)
FINAL ANSWER
6.4525 Kilowatt <-- Power transmitted by belt
(Calculation completed in 00.004 seconds)

Credits

Created by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has created this Calculator and 1000+ more calculators!
Verified by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has verified this Calculator and 1900+ more calculators!

6 Power Transmission Calculators

Drive Power to be Transmitted given Number of Belts Required
Go Power transmitted by belt = Number of Belts*(Correction Factor for Belt Length*Correction Factor for Arc of Contact*Power Rating of Single V-Belt)/Correction Factor for Industrial Service
Power Rating of Single V-Belt given Number of Belts Required
Go Power Rating of Single V-Belt = Power transmitted by belt*Correction Factor for Industrial Service/(Correction Factor for Belt Length*Correction Factor for Arc of Contact*Number of Belts)
Belt Velocity given Power Transmitted using V-Belt
Go Belt Velocity = Power transmitted by belt/(Belt Tension on Tight Side-Belt Tension on Loose Side)
Power Transmitted using V Belt
Go Power transmitted by belt = (Belt Tension on Tight Side-Belt Tension on Loose Side)*Belt Velocity
Belt Tension in Tight Side of Belt given Power Transmitted using V-Belt
Go Belt Tension on Tight Side = Power transmitted by belt/Belt Velocity+Belt Tension on Loose Side
Belt Tension in Loose Side of V-Belt given Power Transmitted
Go Belt Tension on Loose Side = Belt Tension on Tight Side-Power transmitted by belt/Belt Velocity

Power Transmitted using V Belt Formula

Power transmitted by belt = (Belt Tension on Tight Side-Belt Tension on Loose Side)*Belt Velocity
Pt = (P1-P2)*vb

Define Power Tranmsitted?

Power transmission is the movement of energy from its place of generation to a location where it is applied to perform useful work. Power is defined formally as units of energy per unit time.

How to Calculate Power Transmitted using V Belt?

Power Transmitted using V Belt calculator uses Power transmitted by belt = (Belt Tension on Tight Side-Belt Tension on Loose Side)*Belt Velocity to calculate the Power transmitted by belt, The Power Transmitted using V Belt formula is defined as the movement of energy from its place of generation to a location where it is applied to perform useful work. Power is defined formally as units of energy per unit time. Power transmitted by belt is denoted by Pt symbol.

How to calculate Power Transmitted using V Belt using this online calculator? To use this online calculator for Power Transmitted using V Belt, enter Belt Tension on Tight Side (P1), Belt Tension on Loose Side (P2) & Belt Velocity (vb) and hit the calculate button. Here is how the Power Transmitted using V Belt calculation can be explained with given input values -> 0.006452 = (800-550)*25.81.

FAQ

What is Power Transmitted using V Belt?
The Power Transmitted using V Belt formula is defined as the movement of energy from its place of generation to a location where it is applied to perform useful work. Power is defined formally as units of energy per unit time and is represented as Pt = (P1-P2)*vb or Power transmitted by belt = (Belt Tension on Tight Side-Belt Tension on Loose Side)*Belt Velocity. Belt Tension on Tight Side is defined as the belt's tension on the belt's tight side, Belt Tension on Loose Side is defined as the belt's tension on the belt's loose side & Belt Velocity is defined as the velocity of the belt used in a belt drive.
How to calculate Power Transmitted using V Belt?
The Power Transmitted using V Belt formula is defined as the movement of energy from its place of generation to a location where it is applied to perform useful work. Power is defined formally as units of energy per unit time is calculated using Power transmitted by belt = (Belt Tension on Tight Side-Belt Tension on Loose Side)*Belt Velocity. To calculate Power Transmitted using V Belt, you need Belt Tension on Tight Side (P1), Belt Tension on Loose Side (P2) & Belt Velocity (vb). With our tool, you need to enter the respective value for Belt Tension on Tight Side, Belt Tension on Loose Side & Belt Velocity and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Power transmitted by belt?
In this formula, Power transmitted by belt uses Belt Tension on Tight Side, Belt Tension on Loose Side & Belt Velocity. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Power transmitted by belt = Number of Belts*(Correction Factor for Belt Length*Correction Factor for Arc of Contact*Power Rating of Single V-Belt)/Correction Factor for Industrial Service
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!