Pressure intensity of water flowing through fixed ram in hydraulic intensifier Solution

STEP 0: Pre-Calculation Summary
Formula Used
Pressure Intensity in Sliding Cylinder = (Pressure Intensity from supply to fixed cylinder*Area of sliding cylinder of intensifier)/Area of fixed ram of hydraulic intensifier
psc = (p*A1)/A2
This formula uses 4 Variables
Variables Used
Pressure Intensity in Sliding Cylinder - (Measured in Pascal) - Pressure intensity in sliding cylinder is defined as the pressure of water in the sliding cylinder of an hydraulic intensifier.
Pressure Intensity from supply to fixed cylinder - (Measured in Pascal) - Pressure Intensity from supply to fixed cylinder is defined as the pressure in the water that is flowing from the supply to the fixed cylinder of an hydraulic intensifier.
Area of sliding cylinder of intensifier - (Measured in Square Meter) - Area of sliding cylinder of intensifier is the cross sectional area of the sliding cylinder of an hydraulic intensifier.
Area of fixed ram of hydraulic intensifier - (Measured in Square Meter) - Area of fixed ram of hydraulic intensifier is the cross sectional area of the fixed or the non moving ram or cylinder of an hydraulic intensifier.
STEP 1: Convert Input(s) to Base Unit
Pressure Intensity from supply to fixed cylinder: 200000 Newton per Square Meter --> 200000 Pascal (Check conversion ​here)
Area of sliding cylinder of intensifier: 0.47 Square Meter --> 0.47 Square Meter No Conversion Required
Area of fixed ram of hydraulic intensifier: 0.086 Square Meter --> 0.086 Square Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
psc = (p*A1)/A2 --> (200000*0.47)/0.086
Evaluating ... ...
psc = 1093023.25581395
STEP 3: Convert Result to Output's Unit
1093023.25581395 Pascal -->1093023.25581395 Newton per Square Meter (Check conversion ​here)
FINAL ANSWER
1093023.25581395 1.1E+6 Newton per Square Meter <-- Pressure Intensity in Sliding Cylinder
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Shareef Alex
velagapudi ramakrishna siddhartha engineering college (vr siddhartha engineering college), vijayawada
Shareef Alex has created this Calculator and 100+ more calculators!
Verifier Image
Verified by Ravi Khiyani
Shri Govindram Seksaria Institute of Technology and Science (SGSITS), Indore
Ravi Khiyani has verified this Calculator and 300+ more calculators!

2 Hydraulic Intensifier Calculators

Diameter of fixed ram in hydraulic intensifier
​ Go Diameter of Ram = sqrt((4*Pressure Intensity from supply to fixed cylinder*Area of fixed cylinder of intensifier)/(Pressure Intensity in Sliding Cylinder*pi))
Pressure intensity of water flowing through fixed ram in hydraulic intensifier
​ Go Pressure Intensity in Sliding Cylinder = (Pressure Intensity from supply to fixed cylinder*Area of sliding cylinder of intensifier)/Area of fixed ram of hydraulic intensifier

Pressure intensity of water flowing through fixed ram in hydraulic intensifier Formula

Pressure Intensity in Sliding Cylinder = (Pressure Intensity from supply to fixed cylinder*Area of sliding cylinder of intensifier)/Area of fixed ram of hydraulic intensifier
psc = (p*A1)/A2

what is hydraulic intensifier ?

A hydraulic intensifier is a hydraulic machine for transforming hydraulic power at low pressure into a reduced volume at higher pressure.

what is pressure intensity of water ?

The intensity of pressure at a point is defined as the external normal force per unit area. The SI unit of pressure is Pascal which is N/m2. The stress is the resistance offered by the object upon applying the pressure.

How to Calculate Pressure intensity of water flowing through fixed ram in hydraulic intensifier?

Pressure intensity of water flowing through fixed ram in hydraulic intensifier calculator uses Pressure Intensity in Sliding Cylinder = (Pressure Intensity from supply to fixed cylinder*Area of sliding cylinder of intensifier)/Area of fixed ram of hydraulic intensifier to calculate the Pressure Intensity in Sliding Cylinder, The Pressure intensity of water flowing through fixed ram in hydraulic intensifier formula is defined as the external normal force acting per unit area so that the water flows through the fixed hydraulic ram in hydraulic intensifier. Pressure Intensity in Sliding Cylinder is denoted by psc symbol.

How to calculate Pressure intensity of water flowing through fixed ram in hydraulic intensifier using this online calculator? To use this online calculator for Pressure intensity of water flowing through fixed ram in hydraulic intensifier, enter Pressure Intensity from supply to fixed cylinder (p), Area of sliding cylinder of intensifier (A1) & Area of fixed ram of hydraulic intensifier (A2) and hit the calculate button. Here is how the Pressure intensity of water flowing through fixed ram in hydraulic intensifier calculation can be explained with given input values -> 1.1E+6 = (200000*0.47)/0.086.

FAQ

What is Pressure intensity of water flowing through fixed ram in hydraulic intensifier?
The Pressure intensity of water flowing through fixed ram in hydraulic intensifier formula is defined as the external normal force acting per unit area so that the water flows through the fixed hydraulic ram in hydraulic intensifier and is represented as psc = (p*A1)/A2 or Pressure Intensity in Sliding Cylinder = (Pressure Intensity from supply to fixed cylinder*Area of sliding cylinder of intensifier)/Area of fixed ram of hydraulic intensifier. Pressure Intensity from supply to fixed cylinder is defined as the pressure in the water that is flowing from the supply to the fixed cylinder of an hydraulic intensifier, Area of sliding cylinder of intensifier is the cross sectional area of the sliding cylinder of an hydraulic intensifier & Area of fixed ram of hydraulic intensifier is the cross sectional area of the fixed or the non moving ram or cylinder of an hydraulic intensifier.
How to calculate Pressure intensity of water flowing through fixed ram in hydraulic intensifier?
The Pressure intensity of water flowing through fixed ram in hydraulic intensifier formula is defined as the external normal force acting per unit area so that the water flows through the fixed hydraulic ram in hydraulic intensifier is calculated using Pressure Intensity in Sliding Cylinder = (Pressure Intensity from supply to fixed cylinder*Area of sliding cylinder of intensifier)/Area of fixed ram of hydraulic intensifier. To calculate Pressure intensity of water flowing through fixed ram in hydraulic intensifier, you need Pressure Intensity from supply to fixed cylinder (p), Area of sliding cylinder of intensifier (A1) & Area of fixed ram of hydraulic intensifier (A2). With our tool, you need to enter the respective value for Pressure Intensity from supply to fixed cylinder, Area of sliding cylinder of intensifier & Area of fixed ram of hydraulic intensifier and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!