Quadrature Potentiometer Reading Solution

STEP 0: Pre-Calculation Summary
Formula Used
Quadrature Potentiometer Reading = Magnetizing Component of Current*Resistance
Vq = IM*R
This formula uses 3 Variables
Variables Used
Quadrature Potentiometer Reading - (Measured in Volt) - Quadrature Potentiometer Reading is used to measure the in-phase factor of an unknown e.m.f.
Magnetizing Component of Current - (Measured in Ampere) - Magnetizing Component of Current is defined as the current produced due to the magnetization in the primary winding.
Resistance - (Measured in Ohm) - Resistance is a measure of the opposition to current flow in an electrical circuit. Its S.I unit is ohm.
STEP 1: Convert Input(s) to Base Unit
Magnetizing Component of Current: 5.11 Ampere --> 5.11 Ampere No Conversion Required
Resistance: 10.25 Ohm --> 10.25 Ohm No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Vq = IM*R --> 5.11*10.25
Evaluating ... ...
Vq = 52.3775
STEP 3: Convert Result to Output's Unit
52.3775 Volt --> No Conversion Required
FINAL ANSWER
52.3775 Volt <-- Quadrature Potentiometer Reading
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Shobhit Dimri
Bipin Tripathi Kumaon Institute of Technology (BTKIT), Dwarahat
Shobhit Dimri has created this Calculator and 900+ more calculators!
Verifier Image
Verified by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has verified this Calculator and 1900+ more calculators!

9 AC Circuits Calculators

Resistance of Coil in Transfer Type Potentiometer
​ Go Resistance of Coil = (Output Resistance*Voltage across Coil/Voltage across Shunt)*cos(Phase Angle in Coil-Phase Angle in Shunt)
Effective Resistance in Coordinate Type Potentiometer
​ Go Output Resistance = Sensitivity*Voltage across Coil/Voltage across Shunt
In-Phase Potentiometer Reading
​ Go In-Phase Potentiometer Reading = Loss Component of Current in Primary Winding*Resistance
Voltage Magnitude of AC Potentiometer
​ Go Total Voltage AC = sqrt((Voltage 1^2)+(Voltage 2^2))
Quadrature Potentiometer Reading
​ Go Quadrature Potentiometer Reading = Magnetizing Component of Current*Resistance
Full-Scale Voltage Reading
​ Go Full-scale Voltage Reading = Current at Full-Scale Reading*Resistance of Meter
AC Potentiometer Phase Angle
​ Go Phase Angle = atan(Voltage 2/Voltage 1)
Potentiometer Voltage
​ Go Output Voltage = Line Voltage/Voltage Division Ratio
Voltage Output of Volt Ratio Box in Coordinate Type Potentiometer
​ Go Output Voltage = Input Voltage/1.5

Quadrature Potentiometer Reading Formula

Quadrature Potentiometer Reading = Magnetizing Component of Current*Resistance
Vq = IM*R

What is an AC Potentiometer?

An AC Potentiometer measures the unknown ac voltage or EMF similar to DC Potentiometers used for measuring DC voltage.It is a type of electrical instrument used to measure alternating current (AC) voltage. It consists of a variable resistor called a potentiometer and a known reference voltage source.

How to Calculate Quadrature Potentiometer Reading?

Quadrature Potentiometer Reading calculator uses Quadrature Potentiometer Reading = Magnetizing Component of Current*Resistance to calculate the Quadrature Potentiometer Reading, The Quadrature Potentiometer Reading is the product of magnetising component of the current in the primary winding and the standard resistance in an AC Potentiometer. Quadrature Potentiometer Reading is denoted by Vq symbol.

How to calculate Quadrature Potentiometer Reading using this online calculator? To use this online calculator for Quadrature Potentiometer Reading, enter Magnetizing Component of Current (IM) & Resistance (R) and hit the calculate button. Here is how the Quadrature Potentiometer Reading calculation can be explained with given input values -> 52.3775 = 5.11*10.25.

FAQ

What is Quadrature Potentiometer Reading?
The Quadrature Potentiometer Reading is the product of magnetising component of the current in the primary winding and the standard resistance in an AC Potentiometer and is represented as Vq = IM*R or Quadrature Potentiometer Reading = Magnetizing Component of Current*Resistance. Magnetizing Component of Current is defined as the current produced due to the magnetization in the primary winding & Resistance is a measure of the opposition to current flow in an electrical circuit. Its S.I unit is ohm.
How to calculate Quadrature Potentiometer Reading?
The Quadrature Potentiometer Reading is the product of magnetising component of the current in the primary winding and the standard resistance in an AC Potentiometer is calculated using Quadrature Potentiometer Reading = Magnetizing Component of Current*Resistance. To calculate Quadrature Potentiometer Reading, you need Magnetizing Component of Current (IM) & Resistance (R). With our tool, you need to enter the respective value for Magnetizing Component of Current & Resistance and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.