Reactant Concentration of Macrofluid in Mixed Flow Reactor at First Order Solution

STEP 0: Pre-Calculation Summary
Formula Used
Reactant Concentration in Macrofluids = Initial Concentration in Macro and Micro Fluid/(1+(Rate Constant for First Order Reaction*Mean Pulse Curve))
CA,Macrofluids = CA0/(1+(K1*T))
This formula uses 4 Variables
Variables Used
Reactant Concentration in Macrofluids - (Measured in Mole per Cubic Meter) - Reactant Concentration in Macrofluids is the Converted Reactant in the Macrofluid.
Initial Concentration in Macro and Micro Fluid - (Measured in Mole per Cubic Meter) - Initial Concentration in Macro and Micro Fluid refers to the Concentration of that Reactant at the Beginning of a Chemical Reaction, precisely when the Reaction is initiated.
Rate Constant for First Order Reaction - (Measured in 1 Per Second) - The Rate Constant for First Order Reaction is defined as the rate of the reaction divided by the concentration of the reactant.
Mean Pulse Curve - (Measured in Second) - Mean Pulse Curve is the ratio between Volume of Reactor and Volumetric Flow Rate.
STEP 1: Convert Input(s) to Base Unit
Initial Concentration in Macro and Micro Fluid: 80 Mole per Cubic Meter --> 80 Mole per Cubic Meter No Conversion Required
Rate Constant for First Order Reaction: 7.2 1 Per Second --> 7.2 1 Per Second No Conversion Required
Mean Pulse Curve: 3 Second --> 3 Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
CA,Macrofluids = CA0/(1+(K1*T)) --> 80/(1+(7.2*3))
Evaluating ... ...
CA,Macrofluids = 3.53982300884956
STEP 3: Convert Result to Output's Unit
3.53982300884956 Mole per Cubic Meter --> No Conversion Required
FINAL ANSWER
3.53982300884956 3.539823 Mole per Cubic Meter <-- Reactant Concentration in Macrofluids
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Pavan Kumar
Anurag Group of Institutions (AGI), Hyderabad
Pavan Kumar has created this Calculator and 100+ more calculators!
Verifier Image
Verified by Vaibhav Mishra
DJ Sanghvi College of Engineering (DJSCE), Mumbai
Vaibhav Mishra has verified this Calculator and 200+ more calculators!

9 Earliness of Mixing,Segregation,RTD Calculators

Reactant Concentration of Macrofluid in Mixed Flow Reactor at Zero Order
​ Go Reactant Concentration in Macrofluids = Initial Concentration in Macro and Micro Fluid-(Rate Constant of Zero Order Rxns for Macrofluids*Reaction Time*(1-exp(-Initial Concentration in Macro and Micro Fluid/(Rate Constant of Zero Order Rxns for Macrofluids*Reaction Time))))
Reactant Concentration of Microfluid and Macrofluid in Plug Flow Reactor at Second Order
​ Go Concentration of Soln for Macro and Micro Fluid = Initial Concentration in Macro and Micro Fluid/(1+(Initial Concentration in Macro and Micro Fluid*Second Order Rate Constant*Mean Pulse Curve))
Initial Reactant Concentration of Macrofluid in Mixed Flow Reactor at First Order
​ Go Initial Concentration in Macro and Micro Fluid = Reactant Concentration in Macrofluids*(1+(Rate Constant for First Order Reaction*Mean Pulse Curve))
Initial Reactant Concentration of Microfluid in Mixed Flow Reactor at First Order
​ Go Initial Concentration in Macro and Micro Fluid = Reactant Concentration in Microfluids*(1+(Rate Constant for First Order Reaction*Mean Pulse Curve))
Initial Reactant Concentration of Microfluid in Mixed Flow Reactor at Zero Order
​ Go Initial Concentration of Reactant in MFR = Reactant Concentration in Microfluids+(Rate Constant of Zero Order Rxns for Microfluids*Mean Pulse Curve)
Reactant Concentration of Macrofluid in Mixed Flow Reactor at First Order
​ Go Reactant Concentration in Macrofluids = Initial Concentration in Macro and Micro Fluid/(1+(Rate Constant for First Order Reaction*Mean Pulse Curve))
Reactant Concentration of Microfluid treated in Mixed Flow Reactor
​ Go Reactant Concentration = (Initial Concentration in Macro and Micro Fluid-((Rate of Reactant A Determining Concentration)*Mean Pulse Curve))
Initial Reactant Concentration of Microfluid treated in Mixed Flow Reactor
​ Go Initial Concentration of Reactant in MFR = Reactant Concentration in Microfluids+((Rate of Reactant A for Microfluids))*Mean Pulse Curve
Life of Element in Fluid
​ Go Life of Element of Fluid = (Size of Element)^2/Diffusion Coefficient of Flow

Reactant Concentration of Macrofluid in Mixed Flow Reactor at First Order Formula

Reactant Concentration in Macrofluids = Initial Concentration in Macro and Micro Fluid/(1+(Rate Constant for First Order Reaction*Mean Pulse Curve))
CA,Macrofluids = CA0/(1+(K1*T))

What is Macrofluid ?

In a macrofluid, molecules move together in clumps; the clumps are distributed in residence times, but all molecules within a clump have the same age.

What is Mixed Flow Reactor?

The continuous stirred-tank reactor (CSTR), also known as vat- or backmix reactor, mixed flow reactor (MFR), or a continuous-flow stirred-tank reactor (CFSTR), is a common model for a chemical reactor in chemical engineering and environmental engineering. A CSTR often refers to a model used to estimate the key unit operation variables when using a continuous agitated-tank reactor to reach a specified output.

How to Calculate Reactant Concentration of Macrofluid in Mixed Flow Reactor at First Order?

Reactant Concentration of Macrofluid in Mixed Flow Reactor at First Order calculator uses Reactant Concentration in Macrofluids = Initial Concentration in Macro and Micro Fluid/(1+(Rate Constant for First Order Reaction*Mean Pulse Curve)) to calculate the Reactant Concentration in Macrofluids, The Reactant Concentration of Macrofluid in Mixed Flow Reactor at First Order formula is defined as the Concentration of the Reactant, present in the Reactor. Reactant Concentration in Macrofluids is denoted by CA,Macrofluids symbol.

How to calculate Reactant Concentration of Macrofluid in Mixed Flow Reactor at First Order using this online calculator? To use this online calculator for Reactant Concentration of Macrofluid in Mixed Flow Reactor at First Order, enter Initial Concentration in Macro and Micro Fluid (CA0), Rate Constant for First Order Reaction (K1) & Mean Pulse Curve (T) and hit the calculate button. Here is how the Reactant Concentration of Macrofluid in Mixed Flow Reactor at First Order calculation can be explained with given input values -> 3.539823 = 80/(1+(7.2*3)).

FAQ

What is Reactant Concentration of Macrofluid in Mixed Flow Reactor at First Order?
The Reactant Concentration of Macrofluid in Mixed Flow Reactor at First Order formula is defined as the Concentration of the Reactant, present in the Reactor and is represented as CA,Macrofluids = CA0/(1+(K1*T)) or Reactant Concentration in Macrofluids = Initial Concentration in Macro and Micro Fluid/(1+(Rate Constant for First Order Reaction*Mean Pulse Curve)). Initial Concentration in Macro and Micro Fluid refers to the Concentration of that Reactant at the Beginning of a Chemical Reaction, precisely when the Reaction is initiated, The Rate Constant for First Order Reaction is defined as the rate of the reaction divided by the concentration of the reactant & Mean Pulse Curve is the ratio between Volume of Reactor and Volumetric Flow Rate.
How to calculate Reactant Concentration of Macrofluid in Mixed Flow Reactor at First Order?
The Reactant Concentration of Macrofluid in Mixed Flow Reactor at First Order formula is defined as the Concentration of the Reactant, present in the Reactor is calculated using Reactant Concentration in Macrofluids = Initial Concentration in Macro and Micro Fluid/(1+(Rate Constant for First Order Reaction*Mean Pulse Curve)). To calculate Reactant Concentration of Macrofluid in Mixed Flow Reactor at First Order, you need Initial Concentration in Macro and Micro Fluid (CA0), Rate Constant for First Order Reaction (K1) & Mean Pulse Curve (T). With our tool, you need to enter the respective value for Initial Concentration in Macro and Micro Fluid, Rate Constant for First Order Reaction & Mean Pulse Curve and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Reactant Concentration in Macrofluids?
In this formula, Reactant Concentration in Macrofluids uses Initial Concentration in Macro and Micro Fluid, Rate Constant for First Order Reaction & Mean Pulse Curve. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Reactant Concentration in Macrofluids = Initial Concentration in Macro and Micro Fluid-(Rate Constant of Zero Order Rxns for Macrofluids*Reaction Time*(1-exp(-Initial Concentration in Macro and Micro Fluid/(Rate Constant of Zero Order Rxns for Macrofluids*Reaction Time))))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!