Formula Used
Resolution given NP and SF = (sqrt(Number of Theoretical Plates)/4)*(Separation Factor-1)
RNPandSF = (sqrt(N)/4)*(β-1)
This formula uses 1 Functions, 3 Variables
Functions Used
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
Resolution given NP and SF - Resolution given NP and SF is defined as the resolving power of the column.
Number of Theoretical Plates - The Number of Theoretical Plates is defined as used to determine column efficiency based on the calculation in which the larger the theoretical plate number the sharper the peaks.
Separation Factor - The Separation Factor is the term that describes the effectiveness of separation of two solutes.
STEP 1: Convert Input(s) to Base Unit
Number of Theoretical Plates: 10 --> No Conversion Required
Separation Factor: 7 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
RNPandSF = (sqrt(N)/4)*(β-1) --> (sqrt(10)/4)*(7-1)
Evaluating ... ...
RNPandSF = 4.74341649025257
STEP 3: Convert Result to Output's Unit
4.74341649025257 --> No Conversion Required
FINAL ANSWER
4.74341649025257 4.743416 <-- Resolution given NP and SF
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Prashant Singh
K J Somaiya College of science (K J Somaiya), Mumbai
Prashant Singh has created this Calculator and 700+ more calculators!
Verifier Image
Verified by Prerana Bakli
University of Hawaiʻi at Mānoa (UH Manoa), Hawaii, USA
Prerana Bakli has verified this Calculator and 1600+ more calculators!

4 Resolution Calculators

Resolution given Number of Theoretical Plates and Separation Factor
​ Go Resolution given NP and SF = (sqrt(Number of Theoretical Plates)/4)*(Separation Factor-1)
Resolution of Two Peaks given Change in Retention Volume
​ Go Resolution given Retention volume = (Change in retention volume/Average Width of Peaks)
Resolution of Two Peaks given Half of Average Width of Peaks
​ Go Resolution given HP = (0.589*Change in Retention Time)/Half of Average Width of Peaks
Resolution of Two Peaks given Change in Retention Time
​ Go Resolution given NP and SF = (Change in Retention Time/Average Width of Peaks)

Resolution given Number of Theoretical Plates and Separation Factor Formula

Resolution given NP and SF = (sqrt(Number of Theoretical Plates)/4)*(Separation Factor-1)
RNPandSF = (sqrt(N)/4)*(β-1)

What is Chromatography?

A separation process based on the various partitioning coefficients of different solutes between the two phases.
Involving the interaction of solute(s) and two phases
Mobile phase: A gas or liquid that moves through the column.
Stationary phase: A solid or liquid that remains in place.

What are the types of Chromatography?

1) Adsorption chromatography
2) Ion-exchange chromatography
3) Partition chromatography
4) Molecular Size exclusion chromatography
5) Affinity chromatography

How to Calculate Resolution given Number of Theoretical Plates and Separation Factor?

Resolution given Number of Theoretical Plates and Separation Factor calculator uses Resolution given NP and SF = (sqrt(Number of Theoretical Plates)/4)*(Separation Factor-1) to calculate the Resolution given NP and SF, The Resolution given number of theoretical plates and separation factor formula is defined as the relation of resolution of the peak with the square root of a number of the theoretical plates and with the separation factor. Resolution given NP and SF is denoted by RNPandSF symbol.

How to calculate Resolution given Number of Theoretical Plates and Separation Factor using this online calculator? To use this online calculator for Resolution given Number of Theoretical Plates and Separation Factor, enter Number of Theoretical Plates (N) & Separation Factor (β) and hit the calculate button. Here is how the Resolution given Number of Theoretical Plates and Separation Factor calculation can be explained with given input values -> 4.743416 = (sqrt(10)/4)*(7-1).

FAQ

What is Resolution given Number of Theoretical Plates and Separation Factor?
The Resolution given number of theoretical plates and separation factor formula is defined as the relation of resolution of the peak with the square root of a number of the theoretical plates and with the separation factor and is represented as RNPandSF = (sqrt(N)/4)*(β-1) or Resolution given NP and SF = (sqrt(Number of Theoretical Plates)/4)*(Separation Factor-1). The Number of Theoretical Plates is defined as used to determine column efficiency based on the calculation in which the larger the theoretical plate number the sharper the peaks & The Separation Factor is the term that describes the effectiveness of separation of two solutes.
How to calculate Resolution given Number of Theoretical Plates and Separation Factor?
The Resolution given number of theoretical plates and separation factor formula is defined as the relation of resolution of the peak with the square root of a number of the theoretical plates and with the separation factor is calculated using Resolution given NP and SF = (sqrt(Number of Theoretical Plates)/4)*(Separation Factor-1). To calculate Resolution given Number of Theoretical Plates and Separation Factor, you need Number of Theoretical Plates (N) & Separation Factor (β). With our tool, you need to enter the respective value for Number of Theoretical Plates & Separation Factor and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Resolution given NP and SF?
In this formula, Resolution given NP and SF uses Number of Theoretical Plates & Separation Factor. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Resolution given NP and SF = (Change in Retention Time/Average Width of Peaks)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!