RMS Magnitude of Fundamental Source Current for Constant Load Current Solution

STEP 0: Pre-Calculation Summary
Formula Used
RMS Fundamental Current Component Full Converter = 0.707*Load Current Full converter
Irms(full) = 0.707*IL(full)
This formula uses 2 Variables
Variables Used
RMS Fundamental Current Component Full Converter - (Measured in Ampere) - RMS Fundamental Current Component Full Converter is the first harmonic of the current in the harmonic analysis of the square wave of source current.
Load Current Full converter - (Measured in Ampere) - Load Current Full converter is defined as the current flowing through the load terminal of a full converter circuit.
STEP 1: Convert Input(s) to Base Unit
Load Current Full converter: 0.5 Ampere --> 0.5 Ampere No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Irms(full) = 0.707*IL(full) --> 0.707*0.5
Evaluating ... ...
Irms(full) = 0.3535
STEP 3: Convert Result to Output's Unit
0.3535 Ampere --> No Conversion Required
FINAL ANSWER
0.3535 Ampere <-- RMS Fundamental Current Component Full Converter
(Calculation completed in 00.004 seconds)

Credits

Created by Devyaani Garg
Shiv Nadar University (SNU), Greater Noida
Devyaani Garg has created this Calculator and 50+ more calculators!
Verified by Nikita Suryawanshi
Vellore Institute of Technology (VIT), Vellore
Nikita Suryawanshi has verified this Calculator and 25+ more calculators!

10+ Single Phase Full Converter Calculators

Fundamental Component of Source Current for Constant Load Current
Go Fundamental Current Component Full Converter = Load Current Full converter/(sqrt(2)*cos(Power Factor Full Converter))
Real Power for Constant Load Current
Go Real Power Full Converter = Load Voltage Full Converter*Load Current Full converter*cos(Firing Angle Full Converter)
Average DC Output Voltage of Single Phase Full Converter
Go Average Voltage Full Converter = (2*Maximum DC Output Voltage Full Converter*cos(Firing Angle Full Converter))/pi
Apparent Power using RMS Value
Go Apparent Power Full Converter = (Load Current Full converter*Maximum DC Output Voltage Full Converter)/2
Maximum Output DC Voltage of Single Phase Full Converter
Go Maximum DC Output Voltage Full Converter = (2*Maximum Input Voltage Full Converter)/pi
Apparent Power for Constant Load Current
Go Apparent Power Full Converter = Load Current Full converter*Load Voltage Full Converter
RMS Output Voltage of Single Phase Full Converter
Go RMS Output Voltage Full Converter = Maximum Input Voltage Full Converter/(sqrt(2))
Normalized Output Voltage of Single Phase Full Converter
Go Normalized Output Voltage Full Converter = cos(Firing Angle Full Converter)
Total Power Factor for Continuous Load Current
Go Power Factor Full Converter = cos(Firing Angle Full Converter)
RMS Magnitude of Fundamental Source Current for Constant Load Current
Go RMS Fundamental Current Component Full Converter = 0.707*Load Current Full converter

RMS Magnitude of Fundamental Source Current for Constant Load Current Formula

RMS Fundamental Current Component Full Converter = 0.707*Load Current Full converter
Irms(full) = 0.707*IL(full)

How is harmonic analysis useful?

The harmonic is a voltage or current at a multiple of the fundamental frequency of the system, produced by the action of non-linear loads. High levels of Harmonics in the system may lead to overheating component thus causing shorten the life of the equipment, reduced power factors. So, harmonic analysis is needed to use the appropriate harmonics of current or voltage to reduce the overheating problem.

How to Calculate RMS Magnitude of Fundamental Source Current for Constant Load Current?

RMS Magnitude of Fundamental Source Current for Constant Load Current calculator uses RMS Fundamental Current Component Full Converter = 0.707*Load Current Full converter to calculate the RMS Fundamental Current Component Full Converter, The RMS magnitude of fundamental source current for constant load current formula is the first harmonic of the current in the harmonic analysis of the square wave of source current (IS). Here the load current is considered constant. The rms of the fundamental component is found by dividing the fundamental component by √2. RMS Fundamental Current Component Full Converter is denoted by Irms(full) symbol.

How to calculate RMS Magnitude of Fundamental Source Current for Constant Load Current using this online calculator? To use this online calculator for RMS Magnitude of Fundamental Source Current for Constant Load Current, enter Load Current Full converter (IL(full)) and hit the calculate button. Here is how the RMS Magnitude of Fundamental Source Current for Constant Load Current calculation can be explained with given input values -> 0.3535 = 0.707*0.5.

FAQ

What is RMS Magnitude of Fundamental Source Current for Constant Load Current?
The RMS magnitude of fundamental source current for constant load current formula is the first harmonic of the current in the harmonic analysis of the square wave of source current (IS). Here the load current is considered constant. The rms of the fundamental component is found by dividing the fundamental component by √2 and is represented as Irms(full) = 0.707*IL(full) or RMS Fundamental Current Component Full Converter = 0.707*Load Current Full converter. Load Current Full converter is defined as the current flowing through the load terminal of a full converter circuit.
How to calculate RMS Magnitude of Fundamental Source Current for Constant Load Current?
The RMS magnitude of fundamental source current for constant load current formula is the first harmonic of the current in the harmonic analysis of the square wave of source current (IS). Here the load current is considered constant. The rms of the fundamental component is found by dividing the fundamental component by √2 is calculated using RMS Fundamental Current Component Full Converter = 0.707*Load Current Full converter. To calculate RMS Magnitude of Fundamental Source Current for Constant Load Current, you need Load Current Full converter (IL(full)). With our tool, you need to enter the respective value for Load Current Full converter and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!