Rotor Frequency in Induction Motor Solution

STEP 0: Pre-Calculation Summary
Formula Used
Rotor Frequency = (Number of Poles/120)*(Synchronous Speed-Motor Speed)
fr = (n/120)*(Ns-Nm)
This formula uses 4 Variables
Variables Used
Rotor Frequency - (Measured in Hertz) - Rotor frequency is the number of cycles per second of the rotor.
Number of Poles - Number of Polesis defined as the number of poles in an electrical machine for the flux generation.
Synchronous Speed - (Measured in Radian per Second) - Synchronous speed is a definite speed for an alternating-current machine that is dependent on the frequency of the supply circuit.
Motor Speed - (Measured in Radian per Second) - Motor Speed is the speed of the rotor(motor).
STEP 1: Convert Input(s) to Base Unit
Number of Poles: 4 --> No Conversion Required
Synchronous Speed: 15660 Revolution per Minute --> 1639.91136509036 Radian per Second (Check conversion ​here)
Motor Speed: 14350 Revolution per Minute --> 1502.72848589059 Radian per Second (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
fr = (n/120)*(Ns-Nm) --> (4/120)*(1639.91136509036-1502.72848589059)
Evaluating ... ...
fr = 4.57276263999233
STEP 3: Convert Result to Output's Unit
4.57276263999233 Hertz --> No Conversion Required
FINAL ANSWER
4.57276263999233 4.572763 Hertz <-- Rotor Frequency
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Parminder Singh
Chandigarh University (CU), Punjab
Parminder Singh has created this Calculator and 100+ more calculators!
Verifier Image
Verified by Aman Dhussawat
GURU TEGH BAHADUR INSTITUTE OF TECHNOLOGY (GTBIT), NEW DELHI
Aman Dhussawat has verified this Calculator and 100+ more calculators!

3 Frequency Calculators

Rotor Frequency in Induction Motor
​ Go Rotor Frequency = (Number of Poles/120)*(Synchronous Speed-Motor Speed)
Frequency given Number of Poles in Induction Motor
​ Go Frequency = (Number of Poles*Synchronous Speed)/120
Rotor Frequency given Supply Frequency
​ Go Rotor Frequency = Slip*Frequency

Rotor Frequency in Induction Motor Formula

Rotor Frequency = (Number of Poles/120)*(Synchronous Speed-Motor Speed)
fr = (n/120)*(Ns-Nm)

Explain the rotor circuit model?

the greater the relative motion between the rotor and the stator magnetic fields, the greater the resulting rotor voltage and rotorfrequency, The largest relative motion occurs when the rotor is stationary, called the locked-rotor or blocked-rotor condition, so the largest voltage and rotor frequency arc induced in the rotor at that condition,

How to Calculate Rotor Frequency in Induction Motor?

Rotor Frequency in Induction Motor calculator uses Rotor Frequency = (Number of Poles/120)*(Synchronous Speed-Motor Speed) to calculate the Rotor Frequency, The Rotor Frequency in Induction Motor formula is defined as the frequency of the rotating part of an induction motor. Rotor Frequency is denoted by fr symbol.

How to calculate Rotor Frequency in Induction Motor using this online calculator? To use this online calculator for Rotor Frequency in Induction Motor, enter Number of Poles (n), Synchronous Speed (Ns) & Motor Speed (Nm) and hit the calculate button. Here is how the Rotor Frequency in Induction Motor calculation can be explained with given input values -> 4.572763 = (4/120)*(1639.91136509036-1502.72848589059).

FAQ

What is Rotor Frequency in Induction Motor?
The Rotor Frequency in Induction Motor formula is defined as the frequency of the rotating part of an induction motor and is represented as fr = (n/120)*(Ns-Nm) or Rotor Frequency = (Number of Poles/120)*(Synchronous Speed-Motor Speed). Number of Polesis defined as the number of poles in an electrical machine for the flux generation, Synchronous speed is a definite speed for an alternating-current machine that is dependent on the frequency of the supply circuit & Motor Speed is the speed of the rotor(motor).
How to calculate Rotor Frequency in Induction Motor?
The Rotor Frequency in Induction Motor formula is defined as the frequency of the rotating part of an induction motor is calculated using Rotor Frequency = (Number of Poles/120)*(Synchronous Speed-Motor Speed). To calculate Rotor Frequency in Induction Motor, you need Number of Poles (n), Synchronous Speed (Ns) & Motor Speed (Nm). With our tool, you need to enter the respective value for Number of Poles, Synchronous Speed & Motor Speed and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Rotor Frequency?
In this formula, Rotor Frequency uses Number of Poles, Synchronous Speed & Motor Speed. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Rotor Frequency = Slip*Frequency
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!