Static Viscosity using Wall Temperature and Static Temperature Solution

STEP 0: Pre-Calculation Summary
Formula Used
Static Viscosity = Wall Viscosity/(Wall Temperature/Static Temperature)
μe = μw/(Tw/Tstatic)
This formula uses 4 Variables
Variables Used
Static Viscosity - (Measured in Pascal Second) - Static viscosity, is the viscosity of continuous flow, viscosity measures the ratio of the viscous force to the inertial force on the fluid.
Wall Viscosity - (Measured in Pascal Second) - Wall viscosity is the viscosity of fluid in near wall during the turbulent flow.
Wall Temperature - (Measured in Kelvin) - Wall Temperature is the temperature at the wall.
Static Temperature - (Measured in Kelvin) - The Static Temperature is defined as the temperature of the gas if it had no ordered motion and was not flowing.
STEP 1: Convert Input(s) to Base Unit
Wall Viscosity: 0.1 Poise --> 0.01 Pascal Second (Check conversion here)
Wall Temperature: 15 Kelvin --> 15 Kelvin No Conversion Required
Static Temperature: 350 Kelvin --> 350 Kelvin No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
μe = μw/(Tw/Tstatic) --> 0.01/(15/350)
Evaluating ... ...
μe = 0.233333333333333
STEP 3: Convert Result to Output's Unit
0.233333333333333 Pascal Second -->2.33333333333333 Poise (Check conversion here)
FINAL ANSWER
2.33333333333333 2.333333 Poise <-- Static Viscosity
(Calculation completed in 00.004 seconds)

Credits

Created by Sanjay Krishna
Amrita School of Engineering (ASE), Vallikavu
Sanjay Krishna has created this Calculator and 300+ more calculators!
Verified by Maiarutselvan V
PSG College of Technology (PSGCT), Coimbatore
Maiarutselvan V has verified this Calculator and 300+ more calculators!

6 Static Parameters for Hypersonic Flow Calculators

Static Temperature over Flat Plate under Viscous, Very High Mach Flow
Go Static Temperature = Temperature of wall in Kelvin/(((Specific Heat Ratio-1)/2)*Mach Number^2)
Static Temperature of Plate using Wall Viscosity
Go Static Temperature = Temperature of wall in Kelvin/(Wall Viscosity/Static Viscosity)
Static Temperature over Flat Plate using Static Mach Number
Go Static Temperature = Wall Temperature/((1+(Specific Heat Ratio-1)/2)*Mach Number^2)
Static Temperature of Fluid over Flat Plate
Go Static Temperature = Temperature of wall in Kelvin/(Static density/Wall Density)
Static Viscosity using Wall Temperature and Static Temperature
Go Static Viscosity = Wall Viscosity/(Wall Temperature/Static Temperature)
Static Density of Fluid over Flat Plate
Go Static density = Wall Temperature/Static Temperature*Wall Density

Static Viscosity using Wall Temperature and Static Temperature Formula

Static Viscosity = Wall Viscosity/(Wall Temperature/Static Temperature)
μe = μw/(Tw/Tstatic)

What is Viscosity ?

Viscosity is a measure of a fluid's resistance to flow. It describes the internal friction of a moving fluid. A fluid with large viscosity resists motion because its molecular makeup gives it a lot of internal friction.

How to Calculate Static Viscosity using Wall Temperature and Static Temperature?

Static Viscosity using Wall Temperature and Static Temperature calculator uses Static Viscosity = Wall Viscosity/(Wall Temperature/Static Temperature) to calculate the Static Viscosity, The Static viscosity using wall temperature and static temperature formula is defined as the function of wall viscosity, wall temperature, and static temperature. Static Viscosity is denoted by μe symbol.

How to calculate Static Viscosity using Wall Temperature and Static Temperature using this online calculator? To use this online calculator for Static Viscosity using Wall Temperature and Static Temperature, enter Wall Viscosity w), Wall Temperature (Tw) & Static Temperature (Tstatic) and hit the calculate button. Here is how the Static Viscosity using Wall Temperature and Static Temperature calculation can be explained with given input values -> 23.33333 = 0.01/(15/350).

FAQ

What is Static Viscosity using Wall Temperature and Static Temperature?
The Static viscosity using wall temperature and static temperature formula is defined as the function of wall viscosity, wall temperature, and static temperature and is represented as μe = μw/(Tw/Tstatic) or Static Viscosity = Wall Viscosity/(Wall Temperature/Static Temperature). Wall viscosity is the viscosity of fluid in near wall during the turbulent flow, Wall Temperature is the temperature at the wall & The Static Temperature is defined as the temperature of the gas if it had no ordered motion and was not flowing.
How to calculate Static Viscosity using Wall Temperature and Static Temperature?
The Static viscosity using wall temperature and static temperature formula is defined as the function of wall viscosity, wall temperature, and static temperature is calculated using Static Viscosity = Wall Viscosity/(Wall Temperature/Static Temperature). To calculate Static Viscosity using Wall Temperature and Static Temperature, you need Wall Viscosity w), Wall Temperature (Tw) & Static Temperature (Tstatic). With our tool, you need to enter the respective value for Wall Viscosity, Wall Temperature & Static Temperature and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!