Thickness of Column Web given Cross-Sectional Area of Column Web Stiffeners Solution

STEP 0: Pre-Calculation Summary
Formula Used
Column Web Thickness = (Computed Force-(Cross Sectional Plate Area*Stiffener Yield Stress))/(Column Yield Stress*(Flange Thickness+5*Distance Between Flange and Web))
twc = (Pbf-(Acs*Fyst))/(Fyc*(tf+5*K))
This formula uses 7 Variables
Variables Used
Column Web Thickness - (Measured in Millimeter) - Column Web Thickness is the smallest dimension measured perpendicular to height of column web.
Computed Force - (Measured in Kilonewton) - Computed Force delivered by the flange of a moment connection plate multiplied by 5/3 (dead and live loads only) and 4/3 (live and dead loads in conjunction with wind & earthquake forces).
Cross Sectional Plate Area - (Measured in Square Meter) - Cross Sectional Plate Area is the area of a two-dimensional shape that is obtained when a three-dimensional shape is sliced perpendicular to some specified axis at a point.
Stiffener Yield Stress - (Measured in Megapascal) - Stiffener Yield Stress is the minimum stress at which a stiffener will undergo permanent deformation or plastic flow without a significant increase in load.
Column Yield Stress - (Measured in Megapascal) - Column Yield Stress is the minimum stress at which a column will undergo permanent deformation or plastic flow without a significant increase in load.
Flange Thickness - (Measured in Millimeter) - The Flange Thickness is the thickness of a flange in a protruded ridge, lip or rim, either external or internal of a beam such as an I-beam or a T-beam.
Distance Between Flange and Web - (Measured in Millimeter) - Distance Between Flange and Web is the measured distance from the outer face of the flange to the web toe of its fillet if the section is in rolled shape.
STEP 1: Convert Input(s) to Base Unit
Computed Force: 5000 Kilonewton --> 5000 Kilonewton No Conversion Required
Cross Sectional Plate Area: 20 Square Meter --> 20 Square Meter No Conversion Required
Stiffener Yield Stress: 50 Megapascal --> 50 Megapascal No Conversion Required
Column Yield Stress: 50 Megapascal --> 50 Megapascal No Conversion Required
Flange Thickness: 15 Millimeter --> 15 Millimeter No Conversion Required
Distance Between Flange and Web: 5 Millimeter --> 5 Millimeter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
twc = (Pbf-(Acs*Fyst))/(Fyc*(tf+5*K)) --> (5000-(20*50))/(50*(15+5*5))
Evaluating ... ...
twc = 2
STEP 3: Convert Result to Output's Unit
0.002 Meter -->2 Millimeter (Check conversion here)
FINAL ANSWER
2 Millimeter <-- Column Web Thickness
(Calculation completed in 00.004 seconds)

Credits

Created by M Naveen
National Institute of Technology (NIT), Warangal
M Naveen has created this Calculator and 500+ more calculators!
Verified by Mridul Sharma
Indian Institute of Information Technology (IIIT), Bhopal
Mridul Sharma has verified this Calculator and 1700+ more calculators!

12 Design of Stiffeners under Loads Calculators

Distance between Outer Face of Column Flange and Web Toe given Cross-Sectional Area
Go Distance Between Flange and Web = (((Computed Force-(Cross Sectional Plate Area*Stiffener Yield Stress))/(Column Yield Stress*Column Web Thickness))-Flange Thickness)/5
Thickness of Column Web given Cross-Sectional Area of Column Web Stiffeners
Go Column Web Thickness = (Computed Force-(Cross Sectional Plate Area*Stiffener Yield Stress))/(Column Yield Stress*(Flange Thickness+5*Distance Between Flange and Web))
Column Yield Stress given Cross-Sectional Area of Column Web Stiffeners
Go Column Yield Stress = (Computed Force-(Cross Sectional Plate Area*Stiffener Yield Stress))/(Column Web Thickness*(Flange Thickness+5*Distance Between Flange and Web))
Computed Load given Cross-Sectional Area of Column Web Stiffeners
Go Computed Force = (Cross Sectional Plate Area*Stiffener Yield Stress)+(Column Yield Stress*Column Web Thickness*(Flange Thickness+5*Distance Between Flange and Web))
Stiffener Yield Stress given Cross Sectional Area of Column Web Stiffeners
Go Stiffener Yield Stress = (Computed Force-Column Yield Stress*Column Web Thickness*(Flange Thickness+5*Distance Between Flange and Web))/Cross Sectional Plate Area
Cross sectional area of Column Web Stiffeners
Go Cross Sectional Plate Area = (Computed Force-Column Yield Stress*Column Web Thickness*(Flange Thickness+5*Distance Between Flange and Web))/Stiffener Yield Stress
Thickness of Column Web given Column Web Depth Clear of Fillets
Go Column Web Thickness = ((Web Depth*Computed Force)/(4100*sqrt(Column Yield Stress)))^(1/3)
Computed Force for Column-Web Depth of Fillets
Go Computed Force = (4100*Column Web Thickness^3*sqrt(Column Yield Stress))/Web Depth
Column-Web Depth Clear of Fillets
Go Web Depth = (4100*Column Web Thickness^3*sqrt(Column Yield Stress))/Computed Force
Thickness of Column Flange
Go Flange Thickness = 0.4*sqrt(Computed Force/Column Yield Stress)
Tensile Strength of Connected Part using Allowable Bearing Stress
Go Tensile Strength MPA = Allowable Bearing Stress/1.2
Allowable Bearing Stress on Projected Area of Fasteners
Go Allowable Bearing Stress = 1.2*Tensile Strength MPA

Thickness of Column Web given Cross-Sectional Area of Column Web Stiffeners Formula

Column Web Thickness = (Computed Force-(Cross Sectional Plate Area*Stiffener Yield Stress))/(Column Yield Stress*(Flange Thickness+5*Distance Between Flange and Web))
twc = (Pbf-(Acs*Fyst))/(Fyc*(tf+5*K))

What is Computed Force?

The Computed Force is defined as the force delivered by a flange of the moment connection plate when the stiffeners are under load.

What is Allowable Bearing Stress?

The Allowable Bearing Stress is defined as the maximum load that the footing can support without failure with appropriate factors of safety.

How to Calculate Thickness of Column Web given Cross-Sectional Area of Column Web Stiffeners?

Thickness of Column Web given Cross-Sectional Area of Column Web Stiffeners calculator uses Column Web Thickness = (Computed Force-(Cross Sectional Plate Area*Stiffener Yield Stress))/(Column Yield Stress*(Flange Thickness+5*Distance Between Flange and Web)) to calculate the Column Web Thickness, The Thickness of Column Web given Cross-Sectional Area of Column Web Stiffeners formula is defined as the measurement of the column web thickness. Column Web Thickness is denoted by twc symbol.

How to calculate Thickness of Column Web given Cross-Sectional Area of Column Web Stiffeners using this online calculator? To use this online calculator for Thickness of Column Web given Cross-Sectional Area of Column Web Stiffeners, enter Computed Force (Pbf), Cross Sectional Plate Area (Acs), Stiffener Yield Stress (Fyst), Column Yield Stress (Fyc), Flange Thickness (tf) & Distance Between Flange and Web (K) and hit the calculate button. Here is how the Thickness of Column Web given Cross-Sectional Area of Column Web Stiffeners calculation can be explained with given input values -> 2175 = (5000000-(20*50000000))/(50000000*(0.015+5*0.005)).

FAQ

What is Thickness of Column Web given Cross-Sectional Area of Column Web Stiffeners?
The Thickness of Column Web given Cross-Sectional Area of Column Web Stiffeners formula is defined as the measurement of the column web thickness and is represented as twc = (Pbf-(Acs*Fyst))/(Fyc*(tf+5*K)) or Column Web Thickness = (Computed Force-(Cross Sectional Plate Area*Stiffener Yield Stress))/(Column Yield Stress*(Flange Thickness+5*Distance Between Flange and Web)). Computed Force delivered by the flange of a moment connection plate multiplied by 5/3 (dead and live loads only) and 4/3 (live and dead loads in conjunction with wind & earthquake forces), Cross Sectional Plate Area is the area of a two-dimensional shape that is obtained when a three-dimensional shape is sliced perpendicular to some specified axis at a point, Stiffener Yield Stress is the minimum stress at which a stiffener will undergo permanent deformation or plastic flow without a significant increase in load, Column Yield Stress is the minimum stress at which a column will undergo permanent deformation or plastic flow without a significant increase in load, The Flange Thickness is the thickness of a flange in a protruded ridge, lip or rim, either external or internal of a beam such as an I-beam or a T-beam & Distance Between Flange and Web is the measured distance from the outer face of the flange to the web toe of its fillet if the section is in rolled shape.
How to calculate Thickness of Column Web given Cross-Sectional Area of Column Web Stiffeners?
The Thickness of Column Web given Cross-Sectional Area of Column Web Stiffeners formula is defined as the measurement of the column web thickness is calculated using Column Web Thickness = (Computed Force-(Cross Sectional Plate Area*Stiffener Yield Stress))/(Column Yield Stress*(Flange Thickness+5*Distance Between Flange and Web)). To calculate Thickness of Column Web given Cross-Sectional Area of Column Web Stiffeners, you need Computed Force (Pbf), Cross Sectional Plate Area (Acs), Stiffener Yield Stress (Fyst), Column Yield Stress (Fyc), Flange Thickness (tf) & Distance Between Flange and Web (K). With our tool, you need to enter the respective value for Computed Force, Cross Sectional Plate Area, Stiffener Yield Stress, Column Yield Stress, Flange Thickness & Distance Between Flange and Web and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Column Web Thickness?
In this formula, Column Web Thickness uses Computed Force, Cross Sectional Plate Area, Stiffener Yield Stress, Column Yield Stress, Flange Thickness & Distance Between Flange and Web. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Column Web Thickness = ((Web Depth*Computed Force)/(4100*sqrt(Column Yield Stress)))^(1/3)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!