Thickness of Plate for H shaped Column Solution

STEP 0: Pre-Calculation Summary
Formula Used
Minimum Plate Thickness = Flange Thickness of H Shaped Columns*sqrt((3*Actual Bearing Pressure)/Allowable Bending Stress)
t = Tf*sqrt((3*fp)/Fb)
This formula uses 1 Functions, 4 Variables
Functions Used
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
Minimum Plate Thickness - (Measured in Meter) - Minimum Plate Thickness is the distance between the top and bottom surfaces of a flat, solid plate. This distance is typically measured in millimeters or inches.
Flange Thickness of H Shaped Columns - (Measured in Meter) - Flange Thickness of H Shaped Columns is the thickness or the distance through the flange in H shaped columns.
Actual Bearing Pressure - (Measured in Pascal) - Actual Bearing Pressure is the exact bearing capacity of the given structure, in simple words it is the ratio of the applied load to the contact area.
Allowable Bending Stress - (Measured in Pascal) - Allowable Bending Stress is the maximum bending stress that can be applied to a material or a structural element without causing failure.
STEP 1: Convert Input(s) to Base Unit
Flange Thickness of H Shaped Columns: 5 Millimeter --> 0.005 Meter (Check conversion here)
Actual Bearing Pressure: 10 Megapascal --> 10000000 Pascal (Check conversion here)
Allowable Bending Stress: 3 Megapascal --> 3000000 Pascal (Check conversion here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
t = Tf*sqrt((3*fp)/Fb) --> 0.005*sqrt((3*10000000)/3000000)
Evaluating ... ...
t = 0.0158113883008419
STEP 3: Convert Result to Output's Unit
0.0158113883008419 Meter -->15.8113883008419 Millimeter (Check conversion here)
FINAL ANSWER
15.8113883008419 15.81139 Millimeter <-- Minimum Plate Thickness
(Calculation completed in 00.020 seconds)

Credits

Created by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has created this Calculator and 500+ more calculators!
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

8 Column Base Plates Calculators

Thickness of Plate for H shaped Column
Go Minimum Plate Thickness = Flange Thickness of H Shaped Columns*sqrt((3*Actual Bearing Pressure)/Allowable Bending Stress)
Plate Length
Go Bearing or Plate Length = sqrt(Area required by Bearing Plate)+(0.5*((0.95*Column Depth)-(0.80*Width of Plate)))
Column Flange Width given Plate Length
Go Width of Plate = (0.95*Column Depth-(Bearing or Plate Length-sqrt(Area required by Bearing Plate))/0.5)/0.80
Column Depth using Plate Length
Go Column Depth = (Bearing or Plate Length-(sqrt(Area required by Bearing Plate))+(0.80*Width of Plate))/0.95
Thickness of Plate
Go Minimum Plate Thickness = 2*Limiting Size*sqrt(Actual Bearing Pressure/Yield Stress of Steel)
Bearing Pressure given Plate Thickness
Go Actual Bearing Pressure = (Minimum Plate Thickness/(2*Limiting Size))^2*Yield Stress of Steel
Area Required by Base Plate
Go Area required by Bearing Plate = Column Load/(0.7*Specified Compressive Strength of Concrete)
Column Load for given Base Plate Area
Go Column Load = Area required by Bearing Plate*0.7*Specified Compressive Strength of Concrete

Thickness of Plate for H shaped Column Formula

Minimum Plate Thickness = Flange Thickness of H Shaped Columns*sqrt((3*Actual Bearing Pressure)/Allowable Bending Stress)
t = Tf*sqrt((3*fp)/Fb)

What is Base Plate & types of Columns based on Slenderness Ratio?

The Base plates are usually used to distribute column loads over a large enough area of supporting concrete construction that the design bearing strength of the concrete is not exceeded. It acts as a support to transfer the compression load acting over the columns. Column bases are usually assumed to be subject to axial compression and shear only.
Types of columns are as follows:
Long or Slender column: Length is more than critical buckling length and hence fails due to buckling.
Short column: The length is less than the critical buckling length and it fails by shearing.

What is the difference between Columns and Struts?

The Strut is mainly used in roof trusses and steel bridges. The main purpose of a strut is to maintain the rigidity of the structure and to take compressive force and is not designed to take any gravity load, but
the column is designed for various types of loads acting on it such as axial load bending moment gravity load shear forces buckling and horizontal load like earthquake load and wind load.
Both Column and Strut are comprehensive members but the main difference between them is column is a comprehensive member of the frame structure and the strut is a comprehensive member of the truss structure.

How to Calculate Thickness of Plate for H shaped Column?

Thickness of Plate for H shaped Column calculator uses Minimum Plate Thickness = Flange Thickness of H Shaped Columns*sqrt((3*Actual Bearing Pressure)/Allowable Bending Stress) to calculate the Minimum Plate Thickness, The Thickness of Plate for H shaped Column formula is defined as the relation between bearing and bending stress and flange thickness. Minimum Plate Thickness is denoted by t symbol.

How to calculate Thickness of Plate for H shaped Column using this online calculator? To use this online calculator for Thickness of Plate for H shaped Column, enter Flange Thickness of H Shaped Columns (Tf), Actual Bearing Pressure (fp) & Allowable Bending Stress (Fb) and hit the calculate button. Here is how the Thickness of Plate for H shaped Column calculation can be explained with given input values -> 15811.39 = 0.005*sqrt((3*10000000)/3000000).

FAQ

What is Thickness of Plate for H shaped Column?
The Thickness of Plate for H shaped Column formula is defined as the relation between bearing and bending stress and flange thickness and is represented as t = Tf*sqrt((3*fp)/Fb) or Minimum Plate Thickness = Flange Thickness of H Shaped Columns*sqrt((3*Actual Bearing Pressure)/Allowable Bending Stress). Flange Thickness of H Shaped Columns is the thickness or the distance through the flange in H shaped columns, Actual Bearing Pressure is the exact bearing capacity of the given structure, in simple words it is the ratio of the applied load to the contact area & Allowable Bending Stress is the maximum bending stress that can be applied to a material or a structural element without causing failure.
How to calculate Thickness of Plate for H shaped Column?
The Thickness of Plate for H shaped Column formula is defined as the relation between bearing and bending stress and flange thickness is calculated using Minimum Plate Thickness = Flange Thickness of H Shaped Columns*sqrt((3*Actual Bearing Pressure)/Allowable Bending Stress). To calculate Thickness of Plate for H shaped Column, you need Flange Thickness of H Shaped Columns (Tf), Actual Bearing Pressure (fp) & Allowable Bending Stress (Fb). With our tool, you need to enter the respective value for Flange Thickness of H Shaped Columns, Actual Bearing Pressure & Allowable Bending Stress and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Minimum Plate Thickness?
In this formula, Minimum Plate Thickness uses Flange Thickness of H Shaped Columns, Actual Bearing Pressure & Allowable Bending Stress. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Minimum Plate Thickness = 2*Limiting Size*sqrt(Actual Bearing Pressure/Yield Stress of Steel)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!