Total Discharge carried by Drain Solution

STEP 0: Pre-Calculation Summary
Formula Used
Total Discharge Carried by Drain = (4*Coefficient of Permeability)/Spacing Between the Drains*((Maximum Height of the Drained Water Table^2)-(Depth of Imprevious Stratum from Centre of Drains^2))
q = (4*k)/s*((b^2)-(a^2))
This formula uses 5 Variables
Variables Used
Total Discharge Carried by Drain - (Measured in Cubic Meter per Second) - Total discharge carried by drain is the total discharge per unit length carried by drain.
Coefficient of Permeability - (Measured in Meter per Second) - Coefficient of Permeability is the velocity in meters or centimeters per second of water through soils.
Spacing Between the Drains - (Measured in Meter) - Spacing between the drains in meters.
Maximum Height of the Drained Water Table - (Measured in Meter) - Maximum height of the drained water table above the impervious layer in meters.
Depth of Imprevious Stratum from Centre of Drains - (Measured in Meter) - Depth of imprevious stratum from centre of drains in meters.
STEP 1: Convert Input(s) to Base Unit
Coefficient of Permeability: 0.001 Meter per Second --> 0.001 Meter per Second No Conversion Required
Spacing Between the Drains: 15 Meter --> 15 Meter No Conversion Required
Maximum Height of the Drained Water Table: 5.2 Meter --> 5.2 Meter No Conversion Required
Depth of Imprevious Stratum from Centre of Drains: 4.529 Meter --> 4.529 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
q = (4*k)/s*((b^2)-(a^2)) --> (4*0.001)/15*((5.2^2)-(4.529^2))
Evaluating ... ...
q = 0.0017408424
STEP 3: Convert Result to Output's Unit
0.0017408424 Cubic Meter per Second --> No Conversion Required
FINAL ANSWER
0.0017408424 0.001741 Cubic Meter per Second <-- Total Discharge Carried by Drain
(Calculation completed in 00.004 seconds)

Credits

Created by bhuvaneshwari
Coorg institute of technology (CIT), Kodagu
bhuvaneshwari has created this Calculator and 50+ more calculators!
Verified by Ayush Singh
Gautam Buddha University (GBU), Greater Noida
Ayush Singh has verified this Calculator and 100+ more calculators!

2 Relation to Predict the Spacing between Tile Drains Calculators

Spacing between Drains if Discharge is Considered
Go Spacing Between the Drains = (4*Coefficient of Permeability)/Total Discharge Carried by Drain*((Maximum Height of the Drained Water Table^2)-(Depth of Imprevious Stratum from Centre of Drains^2))
Total Discharge carried by Drain
Go Total Discharge Carried by Drain = (4*Coefficient of Permeability)/Spacing Between the Drains*((Maximum Height of the Drained Water Table^2)-(Depth of Imprevious Stratum from Centre of Drains^2))

Total Discharge carried by Drain Formula

Total Discharge Carried by Drain = (4*Coefficient of Permeability)/Spacing Between the Drains*((Maximum Height of the Drained Water Table^2)-(Depth of Imprevious Stratum from Centre of Drains^2))
q = (4*k)/s*((b^2)-(a^2))

What is discharge of a river?

River discharge is the volume of water flowing through a river channel; measured at any given point in cubic meters per second.

What is discharge in drainage?

A discharge is a measure of the quantity of any fluid flow over a unit time. The quantity may be either volume or mass. Thus, the water discharge of a tap (faucet) can be measured with a measuring jug and a stopwatch. Here the discharge might be 1 litre per 15 seconds, equivalent to 67 ml/second or 4 litres/minute.

How to Calculate Total Discharge carried by Drain?

Total Discharge carried by Drain calculator uses Total Discharge Carried by Drain = (4*Coefficient of Permeability)/Spacing Between the Drains*((Maximum Height of the Drained Water Table^2)-(Depth of Imprevious Stratum from Centre of Drains^2)) to calculate the Total Discharge Carried by Drain, The Total Discharge carried by Drain formula is defined as the volumetric flow rate of water that is transported through a given cross-sectional area. Total Discharge Carried by Drain is denoted by q symbol.

How to calculate Total Discharge carried by Drain using this online calculator? To use this online calculator for Total Discharge carried by Drain, enter Coefficient of Permeability (k), Spacing Between the Drains (s), Maximum Height of the Drained Water Table (b) & Depth of Imprevious Stratum from Centre of Drains (a) and hit the calculate button. Here is how the Total Discharge carried by Drain calculation can be explained with given input values -> 0.001741 = (4*0.001)/15*((5.2^2)-(4.529^2)).

FAQ

What is Total Discharge carried by Drain?
The Total Discharge carried by Drain formula is defined as the volumetric flow rate of water that is transported through a given cross-sectional area and is represented as q = (4*k)/s*((b^2)-(a^2)) or Total Discharge Carried by Drain = (4*Coefficient of Permeability)/Spacing Between the Drains*((Maximum Height of the Drained Water Table^2)-(Depth of Imprevious Stratum from Centre of Drains^2)). Coefficient of Permeability is the velocity in meters or centimeters per second of water through soils, Spacing between the drains in meters, Maximum height of the drained water table above the impervious layer in meters & Depth of imprevious stratum from centre of drains in meters.
How to calculate Total Discharge carried by Drain?
The Total Discharge carried by Drain formula is defined as the volumetric flow rate of water that is transported through a given cross-sectional area is calculated using Total Discharge Carried by Drain = (4*Coefficient of Permeability)/Spacing Between the Drains*((Maximum Height of the Drained Water Table^2)-(Depth of Imprevious Stratum from Centre of Drains^2)). To calculate Total Discharge carried by Drain, you need Coefficient of Permeability (k), Spacing Between the Drains (s), Maximum Height of the Drained Water Table (b) & Depth of Imprevious Stratum from Centre of Drains (a). With our tool, you need to enter the respective value for Coefficient of Permeability, Spacing Between the Drains, Maximum Height of the Drained Water Table & Depth of Imprevious Stratum from Centre of Drains and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.