Total Number of Connectors Resisting Total Horizontal Shear Solution

STEP 0: Pre-Calculation Summary
Formula Used
Number of Shear Connectors = Total Horizontal Shear/Allowable Shear for One Connector
N = Vh/q
This formula uses 3 Variables
Variables Used
Number of Shear Connectors - Number of Shear Connectors can be described as the number of connectors required for building construction.
Total Horizontal Shear - (Measured in Newton) - Total Horizontal Shear is the shear force between the maximum positive moment at each end of steel beams or between the point of contra flexure in a continuous beam.
Allowable Shear for One Connector - (Measured in Newton) - Allowable Shear for One Connector is the shear force that can be sustained by one shear connector before failure.
STEP 1: Convert Input(s) to Base Unit
Total Horizontal Shear: 4207.5 Kilonewton --> 4207500 Newton (Check conversion here)
Allowable Shear for One Connector: 175 Newton --> 175 Newton No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
N = Vh/q --> 4207500/175
Evaluating ... ...
N = 24042.8571428571
STEP 3: Convert Result to Output's Unit
24042.8571428571 --> No Conversion Required
FINAL ANSWER
24042.8571428571 24042.86 <-- Number of Shear Connectors
(Calculation completed in 00.020 seconds)

Credits

Created by M Naveen
National Institute of Technology (NIT), Warangal
M Naveen has created this Calculator and 500+ more calculators!
Verified by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has verified this Calculator and 1700+ more calculators!

5 Number of Connectors Required for Building Construction Calculators

Moment at Concentrated Load given Number of Shear Connectors
Go Moment at Concentrated Load = (((Number of Shear Connectors*(Beta-1))+No. of Shear Connectors Required)/(No. of Shear Connectors Required*Beta))*Maximum Moment in Span
Maximum Moment in Span given Number of Shear Connectors
Go Maximum Moment in Span = (Moment at Concentrated Load*No. of Shear Connectors Required*Beta)/((Number of Shear Connectors*(Beta-1))+No. of Shear Connectors Required)
Number of Shear Connectors required between Maximum and Zero Moment
Go No. of Shear Connectors Required = (Number of Shear Connectors*(Beta-1))/(((Moment at Concentrated Load*Beta)/Maximum Moment in Span)-1)
Number of Shear Connectors
Go Number of Shear Connectors = No. of Shear Connectors Required*((((Moment at Concentrated Load*Beta)/Maximum Moment in Span)-1))/(Beta-1)
Total Number of Connectors Resisting Total Horizontal Shear
Go Number of Shear Connectors = Total Horizontal Shear/Allowable Shear for One Connector

Total Number of Connectors Resisting Total Horizontal Shear Formula

Number of Shear Connectors = Total Horizontal Shear/Allowable Shear for One Connector
N = Vh/q

What is a Shear Connector?

The Shear Connector is the steel projection provided on the top flange of steel in a span of a construction building with heavy concentrated loads.

What is Maximum Moment & Total Horizontal Shear?

The Maximum Moment can be represented as where the shear force becomes zero on the particular member of the structure.
The Total Horizontal Shear can be defined as a measure of the resistance to shear stress along the longitudinal axis of a member.

How to Calculate Total Number of Connectors Resisting Total Horizontal Shear?

Total Number of Connectors Resisting Total Horizontal Shear calculator uses Number of Shear Connectors = Total Horizontal Shear/Allowable Shear for One Connector to calculate the Number of Shear Connectors, The Total Number of Connectors Resisting Total Horizontal Shear formula is defined as the total number of shear connectors required by the structure to resist the total horizontal shear Vh. Number of Shear Connectors is denoted by N symbol.

How to calculate Total Number of Connectors Resisting Total Horizontal Shear using this online calculator? To use this online calculator for Total Number of Connectors Resisting Total Horizontal Shear, enter Total Horizontal Shear (Vh) & Allowable Shear for One Connector (q) and hit the calculate button. Here is how the Total Number of Connectors Resisting Total Horizontal Shear calculation can be explained with given input values -> 24.04286 = 4207.5/175.

FAQ

What is Total Number of Connectors Resisting Total Horizontal Shear?
The Total Number of Connectors Resisting Total Horizontal Shear formula is defined as the total number of shear connectors required by the structure to resist the total horizontal shear Vh and is represented as N = Vh/q or Number of Shear Connectors = Total Horizontal Shear/Allowable Shear for One Connector. Total Horizontal Shear is the shear force between the maximum positive moment at each end of steel beams or between the point of contra flexure in a continuous beam & Allowable Shear for One Connector is the shear force that can be sustained by one shear connector before failure.
How to calculate Total Number of Connectors Resisting Total Horizontal Shear?
The Total Number of Connectors Resisting Total Horizontal Shear formula is defined as the total number of shear connectors required by the structure to resist the total horizontal shear Vh is calculated using Number of Shear Connectors = Total Horizontal Shear/Allowable Shear for One Connector. To calculate Total Number of Connectors Resisting Total Horizontal Shear, you need Total Horizontal Shear (Vh) & Allowable Shear for One Connector (q). With our tool, you need to enter the respective value for Total Horizontal Shear & Allowable Shear for One Connector and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Number of Shear Connectors?
In this formula, Number of Shear Connectors uses Total Horizontal Shear & Allowable Shear for One Connector. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Number of Shear Connectors = No. of Shear Connectors Required*((((Moment at Concentrated Load*Beta)/Maximum Moment in Span)-1))/(Beta-1)