Transmitted Coefficient of Current-3 using Transmitted Voltage (Line PL) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Transmission Coefficient of Current = Transmitted Voltage*Impedance of Primary Winding/(Impedance of Tertiary Winding*Incident Voltage)
τi = Vt*Z1/(Z3*Vi)
This formula uses 5 Variables
Variables Used
Transmission Coefficient of Current - The transmission Coefficient Of Current is defined as the ratio of the transmitted current to the incident current of the Transmission line during transient.
Transmitted Voltage - (Measured in Volt) - Transmitted Voltage is defined as the Voltage wave that is traveling through the Load of the Transmission line.
Impedance of Primary Winding - (Measured in Ohm) - The Impedance of Primary Winding is the total of primary Resistance and Reactance.
Impedance of Tertiary Winding - (Measured in Ohm) - Impedance of Tertiary Winding in electrical devices, refers to the amount of opposition faced by the direct or alternating current when it passes through a conductor component, circuit, or system.
Incident Voltage - (Measured in Volt) - The Incident Voltage on the transmission line is equal to half the generator voltage.
STEP 1: Convert Input(s) to Base Unit
Transmitted Voltage: 20 Volt --> 20 Volt No Conversion Required
Impedance of Primary Winding: 18 Ohm --> 18 Ohm No Conversion Required
Impedance of Tertiary Winding: 22 Ohm --> 22 Ohm No Conversion Required
Incident Voltage: 6 Volt --> 6 Volt No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
τi = Vt*Z1/(Z3*Vi) --> 20*18/(22*6)
Evaluating ... ...
τi = 2.72727272727273
STEP 3: Convert Result to Output's Unit
2.72727272727273 --> No Conversion Required
FINAL ANSWER
2.72727272727273 2.727273 <-- Transmission Coefficient of Current
(Calculation completed in 00.004 seconds)

Credits

Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verified by Payal Priya
Birsa Institute of Technology (BIT), Sindri
Payal Priya has verified this Calculator and 1900+ more calculators!

8 Transmitted Coefficient OF Current Calculators

Transmitted Coefficient of Current-2 using Transmitted Voltage (Line PL)
Go Transmission Coefficient of Current = Transmitted Voltage*Impedance of Primary Winding/(Impedance of Secondary Winding*Incident Voltage)
Transmitted Coefficient of Current-3 using Transmitted Voltage (Line PL)
Go Transmission Coefficient of Current = Transmitted Voltage*Impedance of Primary Winding/(Impedance of Tertiary Winding*Incident Voltage)
Transmitted Coefficient of Current-2 using Transmitted Coefficient of Voltage (Line PL)
Go Transmission Coefficient of Current = Transmission Coefficient of Voltage*Impedance of Primary Winding/Impedance of Secondary Winding
Transmitted Coefficient of Current-2 using Impedance-1 and 2 (Line PL)
Go Transmission Coefficient of Current = Transmission Coefficient of Voltage*Impedance of Primary Winding/Impedance of Secondary Winding
Transmitted Coefficient of Current-3 using Impedance-1 and 3 (Line PL)
Go Transmission Coefficient of Current = Transmission Coefficient of Voltage*Impedance of Primary Winding/Impedance of Secondary Winding
Transmitted Coefficient of Current-3 using Transmitted Coefficient of Voltage (Line PL)
Go Transmission Coefficient of Current = Transmission Coefficient of Voltage*Impedance of Primary Winding/Impedance of Tertiary Winding
Transmitted Coefficient of Current-2 (Line PL)
Go Transmission Coefficient of Current = Transmitted Current/Incident Current
Transmitted Coefficient of Current-3 (Line PL)
Go Transmission Coefficient of Current = Transmitted Current/Incident Current

Transmitted Coefficient of Current-3 using Transmitted Voltage (Line PL) Formula

Transmission Coefficient of Current = Transmitted Voltage*Impedance of Primary Winding/(Impedance of Tertiary Winding*Incident Voltage)
τi = Vt*Z1/(Z3*Vi)

Define transmitted voltage.

Transmitted voltage is defined as the Voltage wave that is traveling through the Load of the Transmission line.

How to Calculate Transmitted Coefficient of Current-3 using Transmitted Voltage (Line PL)?

Transmitted Coefficient of Current-3 using Transmitted Voltage (Line PL) calculator uses Transmission Coefficient of Current = Transmitted Voltage*Impedance of Primary Winding/(Impedance of Tertiary Winding*Incident Voltage) to calculate the Transmission Coefficient of Current, The Transmitted Coefficient of Current-3 using Transmitted Voltage (line PL) formula is defined as the ratio of the transmitted current-3 to the incident current of the Transmission line. Transmission Coefficient of Current is denoted by τi symbol.

How to calculate Transmitted Coefficient of Current-3 using Transmitted Voltage (Line PL) using this online calculator? To use this online calculator for Transmitted Coefficient of Current-3 using Transmitted Voltage (Line PL), enter Transmitted Voltage (Vt), Impedance of Primary Winding (Z1), Impedance of Tertiary Winding (Z3) & Incident Voltage (Vi) and hit the calculate button. Here is how the Transmitted Coefficient of Current-3 using Transmitted Voltage (Line PL) calculation can be explained with given input values -> 2.727273 = 20*18/(22*6).

FAQ

What is Transmitted Coefficient of Current-3 using Transmitted Voltage (Line PL)?
The Transmitted Coefficient of Current-3 using Transmitted Voltage (line PL) formula is defined as the ratio of the transmitted current-3 to the incident current of the Transmission line and is represented as τi = Vt*Z1/(Z3*Vi) or Transmission Coefficient of Current = Transmitted Voltage*Impedance of Primary Winding/(Impedance of Tertiary Winding*Incident Voltage). Transmitted Voltage is defined as the Voltage wave that is traveling through the Load of the Transmission line, The Impedance of Primary Winding is the total of primary Resistance and Reactance, Impedance of Tertiary Winding in electrical devices, refers to the amount of opposition faced by the direct or alternating current when it passes through a conductor component, circuit, or system & The Incident Voltage on the transmission line is equal to half the generator voltage.
How to calculate Transmitted Coefficient of Current-3 using Transmitted Voltage (Line PL)?
The Transmitted Coefficient of Current-3 using Transmitted Voltage (line PL) formula is defined as the ratio of the transmitted current-3 to the incident current of the Transmission line is calculated using Transmission Coefficient of Current = Transmitted Voltage*Impedance of Primary Winding/(Impedance of Tertiary Winding*Incident Voltage). To calculate Transmitted Coefficient of Current-3 using Transmitted Voltage (Line PL), you need Transmitted Voltage (Vt), Impedance of Primary Winding (Z1), Impedance of Tertiary Winding (Z3) & Incident Voltage (Vi). With our tool, you need to enter the respective value for Transmitted Voltage, Impedance of Primary Winding, Impedance of Tertiary Winding & Incident Voltage and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Transmission Coefficient of Current?
In this formula, Transmission Coefficient of Current uses Transmitted Voltage, Impedance of Primary Winding, Impedance of Tertiary Winding & Incident Voltage. We can use 7 other way(s) to calculate the same, which is/are as follows -
  • Transmission Coefficient of Current = Transmitted Current/Incident Current
  • Transmission Coefficient of Current = Transmission Coefficient of Voltage*Impedance of Primary Winding/Impedance of Secondary Winding
  • Transmission Coefficient of Current = Transmission Coefficient of Voltage*Impedance of Primary Winding/Impedance of Secondary Winding
  • Transmission Coefficient of Current = Transmission Coefficient of Voltage*Impedance of Primary Winding/Impedance of Secondary Winding
  • Transmission Coefficient of Current = Transmitted Current/Incident Current
  • Transmission Coefficient of Current = Transmission Coefficient of Voltage*Impedance of Primary Winding/Impedance of Tertiary Winding
  • Transmission Coefficient of Current = Transmitted Voltage*Impedance of Primary Winding/(Impedance of Secondary Winding*Incident Voltage)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!