Uniform Pressure on Soil given Maximum Moment Solution

STEP 0: Pre-Calculation Summary
Formula Used
Uniform Pressure on Soil = (8*Maximum Moment)/((Width of Footing-Wall Thickness)^2)
P = (8*M'max)/((b-t)^2)
This formula uses 4 Variables
Variables Used
Uniform Pressure on Soil - (Measured in Pascal) - Uniform Pressure on Soil is described as the pressure incurred at the soil under the wall footing.
Maximum Moment - (Measured in Newton Meter) - The maximum Moment is the absolute value of the maximum moment in the unbraced beam segment.
Width of Footing - (Measured in Meter) - Width of Footing is the shorter dimension of the footing.
Wall Thickness - (Measured in Meter) - Wall Thickness is simply the width of the wall that we are taking under consideration.
STEP 1: Convert Input(s) to Base Unit
Maximum Moment: 50.01 Newton Meter --> 50.01 Newton Meter No Conversion Required
Width of Footing: 0.2 Meter --> 0.2 Meter No Conversion Required
Wall Thickness: 7.83 Meter --> 7.83 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
P = (8*M'max)/((b-t)^2) --> (8*50.01)/((0.2-7.83)^2)
Evaluating ... ...
P = 6.87223125930786
STEP 3: Convert Result to Output's Unit
6.87223125930786 Pascal --> No Conversion Required
FINAL ANSWER
6.87223125930786 6.872231 Pascal <-- Uniform Pressure on Soil
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by M Naveen
National Institute of Technology (NIT), Warangal
M Naveen has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

3 Footing Calculators

Uniform Pressure on Soil given Maximum Moment
​ Go Uniform Pressure on Soil = (8*Maximum Moment)/((Width of Footing-Wall Thickness)^2)
Maximum Moment for Symmetrical Concrete Wall Footing
​ Go Maximum Moment = (Uniform Pressure on Soil/8)*(Width of Footing-Wall Thickness)^2
Tensile Bending Stress at Bottom when Footing is Deep
​ Go Tensile Bending Stress = (6*Factored Moment/Depth of Footing^2)

Uniform Pressure on Soil given Maximum Moment Formula

Uniform Pressure on Soil = (8*Maximum Moment)/((Width of Footing-Wall Thickness)^2)
P = (8*M'max)/((b-t)^2)

How to Calculate Uniform Pressure on Soil?

Uniform pressure on soil can be calculated on the basis of weight of concrete footing in an area of soil by using the above formula.

How to Calculate Uniform Pressure on Soil given Maximum Moment?

Uniform Pressure on Soil given Maximum Moment calculator uses Uniform Pressure on Soil = (8*Maximum Moment)/((Width of Footing-Wall Thickness)^2) to calculate the Uniform Pressure on Soil, The Uniform Pressure on Soil given Maximum Moment formula is defined as the pressure occured on the soil due to weight of concrete wall footing uniformly. Uniform Pressure on Soil is denoted by P symbol.

How to calculate Uniform Pressure on Soil given Maximum Moment using this online calculator? To use this online calculator for Uniform Pressure on Soil given Maximum Moment, enter Maximum Moment (M'max), Width of Footing (b) & Wall Thickness (t) and hit the calculate button. Here is how the Uniform Pressure on Soil given Maximum Moment calculation can be explained with given input values -> 6.870857 = (8*50.01)/((0.2-7.83)^2).

FAQ

What is Uniform Pressure on Soil given Maximum Moment?
The Uniform Pressure on Soil given Maximum Moment formula is defined as the pressure occured on the soil due to weight of concrete wall footing uniformly and is represented as P = (8*M'max)/((b-t)^2) or Uniform Pressure on Soil = (8*Maximum Moment)/((Width of Footing-Wall Thickness)^2). The maximum Moment is the absolute value of the maximum moment in the unbraced beam segment, Width of Footing is the shorter dimension of the footing & Wall Thickness is simply the width of the wall that we are taking under consideration.
How to calculate Uniform Pressure on Soil given Maximum Moment?
The Uniform Pressure on Soil given Maximum Moment formula is defined as the pressure occured on the soil due to weight of concrete wall footing uniformly is calculated using Uniform Pressure on Soil = (8*Maximum Moment)/((Width of Footing-Wall Thickness)^2). To calculate Uniform Pressure on Soil given Maximum Moment, you need Maximum Moment (M'max), Width of Footing (b) & Wall Thickness (t). With our tool, you need to enter the respective value for Maximum Moment, Width of Footing & Wall Thickness and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!