Value of Omega if Neutral Axis is in Flange Solution

STEP 0: Pre-Calculation Summary
Formula Used
Value of Omega = Distance from Compression Fiber to NA*Constant β1/(1.18*Effective Depth of Beam)
ω = Kd*β1/(1.18*deff)
This formula uses 4 Variables
Variables Used
Value of Omega - The Value of Omega is a simplified variable used instead of (As*Fy)/(b*d*fc').
Distance from Compression Fiber to NA - (Measured in Meter) - Distance from Compression Fiber to NA is the distance from the extreme compression fiber or surface to the neutral axis.
Constant β1 - Constant β1 is the value used for determining the distance from compression fiber to neutral axis.
Effective Depth of Beam - (Measured in Meter) - Effective Depth of Beam is the distance from the centroid of tension steel to the outermost face of the compression fiber.
STEP 1: Convert Input(s) to Base Unit
Distance from Compression Fiber to NA: 100.2 Millimeter --> 0.1002 Meter (Check conversion ​here)
Constant β1: 2.4 --> No Conversion Required
Effective Depth of Beam: 4 Meter --> 4 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
ω = Kd*β1/(1.18*deff) --> 0.1002*2.4/(1.18*4)
Evaluating ... ...
ω = 0.0509491525423729
STEP 3: Convert Result to Output's Unit
0.0509491525423729 --> No Conversion Required
FINAL ANSWER
0.0509491525423729 0.050949 <-- Value of Omega
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Mridul Sharma
Indian Institute of Information Technology (IIIT), Bhopal
Mridul Sharma has created this Calculator and 200+ more calculators!
Verifier Image
Verified by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has verified this Calculator and 1700+ more calculators!

4 Flanged Sections Calculators

Maximum Ultimate Moment when Neutral Axis Lies in Web
​ Go Maximum Ultimate Moment = 0.9*((Area of Tension Reinforcement-Tensile Steel Area for Strength)*Yield Strength of Steel*(Effective Depth of Beam-Equivalent Depth/2)+Tensile Steel Area for Strength*Yield Strength of Steel*(Effective Depth of Beam-Flange Thickness/2))
Value of Omega if Neutral Axis is in Flange
​ Go Value of Omega = Distance from Compression Fiber to NA*Constant β1/(1.18*Effective Depth of Beam)
Distance when Neutral Axis Lies in Flange
​ Go Distance from Compression Fiber to NA = (1.18*Value of Omega*Effective Depth of Beam)/Constant β1
Depth when Neutral Axis is in Flange
​ Go Effective Depth of Beam = Distance from Compression Fiber to NA*Constant β1/(1.18*Value of Omega)

Value of Omega if Neutral Axis is in Flange Formula

Value of Omega = Distance from Compression Fiber to NA*Constant β1/(1.18*Effective Depth of Beam)
ω = Kd*β1/(1.18*deff)

What is a Flange?

A flange is a projecting ridge, rim, collar or ring on an object such as a column, beam, pipe and so on that provides additional strength or stiffness or additional surface area for the attachment of, or to, another object.

How to Calculate Value of Omega if Neutral Axis is in Flange?

Value of Omega if Neutral Axis is in Flange calculator uses Value of Omega = Distance from Compression Fiber to NA*Constant β1/(1.18*Effective Depth of Beam) to calculate the Value of Omega, Value of omega if neutral axis is in flange formula calculates omega when the distance c from compression surface to neutral axis is known and the neutral axis lies in the flange. Value of Omega is denoted by ω symbol.

How to calculate Value of Omega if Neutral Axis is in Flange using this online calculator? To use this online calculator for Value of Omega if Neutral Axis is in Flange, enter Distance from Compression Fiber to NA (Kd), Constant β1 (β1) & Effective Depth of Beam (deff) and hit the calculate button. Here is how the Value of Omega if Neutral Axis is in Flange calculation can be explained with given input values -> 0.050847 = 0.1002*2.4/(1.18*4).

FAQ

What is Value of Omega if Neutral Axis is in Flange?
Value of omega if neutral axis is in flange formula calculates omega when the distance c from compression surface to neutral axis is known and the neutral axis lies in the flange and is represented as ω = Kd*β1/(1.18*deff) or Value of Omega = Distance from Compression Fiber to NA*Constant β1/(1.18*Effective Depth of Beam). Distance from Compression Fiber to NA is the distance from the extreme compression fiber or surface to the neutral axis, Constant β1 is the value used for determining the distance from compression fiber to neutral axis & Effective Depth of Beam is the distance from the centroid of tension steel to the outermost face of the compression fiber.
How to calculate Value of Omega if Neutral Axis is in Flange?
Value of omega if neutral axis is in flange formula calculates omega when the distance c from compression surface to neutral axis is known and the neutral axis lies in the flange is calculated using Value of Omega = Distance from Compression Fiber to NA*Constant β1/(1.18*Effective Depth of Beam). To calculate Value of Omega if Neutral Axis is in Flange, you need Distance from Compression Fiber to NA (Kd), Constant β1 (β1) & Effective Depth of Beam (deff). With our tool, you need to enter the respective value for Distance from Compression Fiber to NA, Constant β1 & Effective Depth of Beam and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.