Quality Factor of Hay Bridge using Capacitance Solution

STEP 0: Pre-Calculation Summary
Formula Used
Quality Factor in Hay Bridge = 1/(Capacitance in Hay Bridge*Known Resistance 4 in Hay Bridge*Angular Frequency)
Q(hay) = 1/(C4(hay)*R4(hay)*ω)
This formula uses 4 Variables
Variables Used
Quality Factor in Hay Bridge - Quality Factor in Hay Bridge refers to a measure of the efficiency and performance of an inductor or resonant circuit.
Capacitance in Hay Bridge - (Measured in Farad) - Capacitance in Hay Bridge refers to the capacitance connected in series with non-inductive resistance whose value is known and is varied in the bridge circuit.
Known Resistance 4 in Hay Bridge - (Measured in Ohm) - Known Resistance 4 in Hay Bridge refers to the capacitive resistor whose value is known and is varied in the bridge circuit.
Angular Frequency - (Measured in Radian per Second) - Angular Frequency relates to the rate at which an object or system oscillates or rotates in circular motion.
STEP 1: Convert Input(s) to Base Unit
Capacitance in Hay Bridge: 260 Microfarad --> 0.00026 Farad (Check conversion here)
Known Resistance 4 in Hay Bridge: 24.5 Ohm --> 24.5 Ohm No Conversion Required
Angular Frequency: 200 Radian per Second --> 200 Radian per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Q(hay) = 1/(C4(hay)*R4(hay)*ω) --> 1/(0.00026*24.5*200)
Evaluating ... ...
Q(hay) = 0.784929356357928
STEP 3: Convert Result to Output's Unit
0.784929356357928 --> No Conversion Required
FINAL ANSWER
0.784929356357928 0.784929 <-- Quality Factor in Hay Bridge
(Calculation completed in 00.004 seconds)

Credits

Created by Nikita Suryawanshi
Vellore Institute of Technology (VIT), Vellore
Nikita Suryawanshi has created this Calculator and 100+ more calculators!
Verified by Payal Priya
Birsa Institute of Technology (BIT), Sindri
Payal Priya has verified this Calculator and 1900+ more calculators!

3 Hay Bridge Calculators

Unknown Resistance of Hay Bridge
Go Unknown Resistance in Hay Bridge = (Angular Frequency^2*Known Resistance 2 in Hay Bridge*Known Resistance 3 in Hay Bridge*Known Resistance 4 in Hay Bridge*Capacitance in Hay Bridge^2)/(1+(Angular Frequency^2*Known Resistance 4 in Hay Bridge^2*Capacitance in Hay Bridge^2))
Unknown Inductance in Hay Bridge
Go Unknown Inductance in Hay Bridge = (Known Resistance 2 in Hay Bridge*Known Resistance 3 in Hay Bridge*Capacitance in Hay Bridge)/(1+Angular Frequency^2*Capacitance in Hay Bridge^2*Known Resistance 4 in Hay Bridge^2)
Quality Factor of Hay Bridge using Capacitance
Go Quality Factor in Hay Bridge = 1/(Capacitance in Hay Bridge*Known Resistance 4 in Hay Bridge*Angular Frequency)

Quality Factor of Hay Bridge using Capacitance Formula

Quality Factor in Hay Bridge = 1/(Capacitance in Hay Bridge*Known Resistance 4 in Hay Bridge*Angular Frequency)
Q(hay) = 1/(C4(hay)*R4(hay)*ω)

What are the limitations for Hay bridge?

Hay bridge is a type of stress analysis that takes into account the effects of quality factors such as material properties, manufacturing variability, and testing errors. The limitations of Hay bridge include the assumption of linear elastic behavior, the simplification of complex geometries, and the neglect of non-probabilistic errors. Additionally, the accuracy of Hay bridge depends on the quality of the input data and assumptions made.

How to Calculate Quality Factor of Hay Bridge using Capacitance?

Quality Factor of Hay Bridge using Capacitance calculator uses Quality Factor in Hay Bridge = 1/(Capacitance in Hay Bridge*Known Resistance 4 in Hay Bridge*Angular Frequency) to calculate the Quality Factor in Hay Bridge, The Quality Factor of Hay Bridge using Capacitance formula is used to calculate the quality factor of Hay bridge. It is dependent on the elements in arm AD. Quality Factor in Hay Bridge is denoted by Q(hay) symbol.

How to calculate Quality Factor of Hay Bridge using Capacitance using this online calculator? To use this online calculator for Quality Factor of Hay Bridge using Capacitance, enter Capacitance in Hay Bridge (C4(hay)), Known Resistance 4 in Hay Bridge (R4(hay)) & Angular Frequency (ω) and hit the calculate button. Here is how the Quality Factor of Hay Bridge using Capacitance calculation can be explained with given input values -> 0.784929 = 1/(0.00026*24.5*200).

FAQ

What is Quality Factor of Hay Bridge using Capacitance?
The Quality Factor of Hay Bridge using Capacitance formula is used to calculate the quality factor of Hay bridge. It is dependent on the elements in arm AD and is represented as Q(hay) = 1/(C4(hay)*R4(hay)*ω) or Quality Factor in Hay Bridge = 1/(Capacitance in Hay Bridge*Known Resistance 4 in Hay Bridge*Angular Frequency). Capacitance in Hay Bridge refers to the capacitance connected in series with non-inductive resistance whose value is known and is varied in the bridge circuit, Known Resistance 4 in Hay Bridge refers to the capacitive resistor whose value is known and is varied in the bridge circuit & Angular Frequency relates to the rate at which an object or system oscillates or rotates in circular motion.
How to calculate Quality Factor of Hay Bridge using Capacitance?
The Quality Factor of Hay Bridge using Capacitance formula is used to calculate the quality factor of Hay bridge. It is dependent on the elements in arm AD is calculated using Quality Factor in Hay Bridge = 1/(Capacitance in Hay Bridge*Known Resistance 4 in Hay Bridge*Angular Frequency). To calculate Quality Factor of Hay Bridge using Capacitance, you need Capacitance in Hay Bridge (C4(hay)), Known Resistance 4 in Hay Bridge (R4(hay)) & Angular Frequency (ω). With our tool, you need to enter the respective value for Capacitance in Hay Bridge, Known Resistance 4 in Hay Bridge & Angular Frequency and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!