Resistance Ratio in Wien Bridge Solution

STEP 0: Pre-Calculation Summary
Formula Used
Resistance Ratio in Wein Bridge = (Known Resistance 2 in Wein Bridge/Known Resistance 1 in Wein Bridge)+(Known Capacitance 1 in Wein Bridge/Known Capacitance 2 in Wein Bridge)
RR(wein) = (R2(wein)/R1(wein))+(C1(wein)/C2(wein))
This formula uses 5 Variables
Variables Used
Resistance Ratio in Wein Bridge - Resistance Ratio in Wein Bridge refers to the ratio of resistance connected to arm 3 and arm 4 of a Wein bridge circuit.
Known Resistance 2 in Wein Bridge - (Measured in Ohm) - Known Resistance 2 in Wein Bridge refers to the total resistance in Wein bridge which is variable and can be used to determine the frequency.
Known Resistance 1 in Wein Bridge - (Measured in Ohm) - Known Resistance 1 in Wein Bridge refers to the total resistance in Wein bridge which is variable and can be used to determine the frequency.
Known Capacitance 1 in Wein Bridge - (Measured in Farad) - Known Capacitance 1 in Wein Bridge refers to the total capacitance in Wein bridge which is variable and can be used to determine the frequency.
Known Capacitance 2 in Wein Bridge - (Measured in Farad) - Known Capacitance 2 in Wein Bridge refers to the total capacitance in Wein bridge which is variable and can be used to determine the frequency.
STEP 1: Convert Input(s) to Base Unit
Known Resistance 2 in Wein Bridge: 26 Ohm --> 26 Ohm No Conversion Required
Known Resistance 1 in Wein Bridge: 27 Ohm --> 27 Ohm No Conversion Required
Known Capacitance 1 in Wein Bridge: 270 Microfarad --> 0.00027 Farad (Check conversion ​here)
Known Capacitance 2 in Wein Bridge: 275 Microfarad --> 0.000275 Farad (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
RR(wein) = (R2(wein)/R1(wein))+(C1(wein)/C2(wein)) --> (26/27)+(0.00027/0.000275)
Evaluating ... ...
RR(wein) = 1.94478114478114
STEP 3: Convert Result to Output's Unit
1.94478114478114 --> No Conversion Required
FINAL ANSWER
1.94478114478114 1.944781 <-- Resistance Ratio in Wein Bridge
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Nikita Suryawanshi
Vellore Institute of Technology (VIT), Vellore
Nikita Suryawanshi has created this Calculator and 100+ more calculators!
Verifier Image
Verified by Devyaani Garg
Shiv Nadar University (SNU), Greater Noida
Devyaani Garg has verified this Calculator and 25+ more calculators!

3 Wien Bridge Calculators

Unknown Frequency in Wien Bridge
​ Go Unknown Frequency in Wein Bridge = 1/(2*pi*(sqrt(Known Resistance 1 in Wein Bridge*Known Resistance 2 in Wein Bridge*Known Capacitance 1 in Wein Bridge*Known Capacitance 2 in Wein Bridge)))
Angular Frequency in Wien's Bridge
​ Go Angular Frequency in Wein Bridge = 1/sqrt(Known Resistance 1 in Wein Bridge*Known Resistance 2 in Wein Bridge*Known Capacitance 1 in Wein Bridge*Known Capacitance 2 in Wein Bridge)
Resistance Ratio in Wien Bridge
​ Go Resistance Ratio in Wein Bridge = (Known Resistance 2 in Wein Bridge/Known Resistance 1 in Wein Bridge)+(Known Capacitance 1 in Wein Bridge/Known Capacitance 2 in Wein Bridge)

Resistance Ratio in Wien Bridge Formula

Resistance Ratio in Wein Bridge = (Known Resistance 2 in Wein Bridge/Known Resistance 1 in Wein Bridge)+(Known Capacitance 1 in Wein Bridge/Known Capacitance 2 in Wein Bridge)
RR(wein) = (R2(wein)/R1(wein))+(C1(wein)/C2(wein))

What are the limitations of Wien's bridge?

Wien's bridge is a sensitive thermometric technique, but it has some limitations. Firstly, it is only applicable to thin samples, as the heat flow is too small to be measured in thick samples. Secondly, the technique is sensitive to vibrations, which can introduce errors in the measurement.

How to Calculate Resistance Ratio in Wien Bridge?

Resistance Ratio in Wien Bridge calculator uses Resistance Ratio in Wein Bridge = (Known Resistance 2 in Wein Bridge/Known Resistance 1 in Wein Bridge)+(Known Capacitance 1 in Wein Bridge/Known Capacitance 2 in Wein Bridge) to calculate the Resistance Ratio in Wein Bridge, The Resistance Ratio in Wien Bridge formula is used to determine the relationship between the impedances of the bridge. Resistance Ratio in Wein Bridge is denoted by RR(wein) symbol.

How to calculate Resistance Ratio in Wien Bridge using this online calculator? To use this online calculator for Resistance Ratio in Wien Bridge, enter Known Resistance 2 in Wein Bridge (R2(wein)), Known Resistance 1 in Wein Bridge (R1(wein)), Known Capacitance 1 in Wein Bridge (C1(wein)) & Known Capacitance 2 in Wein Bridge (C2(wein)) and hit the calculate button. Here is how the Resistance Ratio in Wien Bridge calculation can be explained with given input values -> 1.944781 = (26/27)+(0.00027/0.000275).

FAQ

What is Resistance Ratio in Wien Bridge?
The Resistance Ratio in Wien Bridge formula is used to determine the relationship between the impedances of the bridge and is represented as RR(wein) = (R2(wein)/R1(wein))+(C1(wein)/C2(wein)) or Resistance Ratio in Wein Bridge = (Known Resistance 2 in Wein Bridge/Known Resistance 1 in Wein Bridge)+(Known Capacitance 1 in Wein Bridge/Known Capacitance 2 in Wein Bridge). Known Resistance 2 in Wein Bridge refers to the total resistance in Wein bridge which is variable and can be used to determine the frequency, Known Resistance 1 in Wein Bridge refers to the total resistance in Wein bridge which is variable and can be used to determine the frequency, Known Capacitance 1 in Wein Bridge refers to the total capacitance in Wein bridge which is variable and can be used to determine the frequency & Known Capacitance 2 in Wein Bridge refers to the total capacitance in Wein bridge which is variable and can be used to determine the frequency.
How to calculate Resistance Ratio in Wien Bridge?
The Resistance Ratio in Wien Bridge formula is used to determine the relationship between the impedances of the bridge is calculated using Resistance Ratio in Wein Bridge = (Known Resistance 2 in Wein Bridge/Known Resistance 1 in Wein Bridge)+(Known Capacitance 1 in Wein Bridge/Known Capacitance 2 in Wein Bridge). To calculate Resistance Ratio in Wien Bridge, you need Known Resistance 2 in Wein Bridge (R2(wein)), Known Resistance 1 in Wein Bridge (R1(wein)), Known Capacitance 1 in Wein Bridge (C1(wein)) & Known Capacitance 2 in Wein Bridge (C2(wein)). With our tool, you need to enter the respective value for Known Resistance 2 in Wein Bridge, Known Resistance 1 in Wein Bridge, Known Capacitance 1 in Wein Bridge & Known Capacitance 2 in Wein Bridge and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.