Volume of Conductor Material(Single-Phase Two-Wire OS) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Volume of Conductor = 2*Area of Overhead AC Wire*Length of Overhead AC Wire
V = 2*A*L
This formula uses 3 Variables
Variables Used
Volume of Conductor - (Measured in Cubic Meter) - Volume of Conductor is the total volume of the material used to make the conductor of an overhead ac line.
Area of Overhead AC Wire - (Measured in Square Meter) - Area of Overhead AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
Length of Overhead AC Wire - (Measured in Meter) - Length of Overhead AC Wire is the total length of the wire from one end to other end.
STEP 1: Convert Input(s) to Base Unit
Area of Overhead AC Wire: 0.79 Square Meter --> 0.79 Square Meter No Conversion Required
Length of Overhead AC Wire: 10.63 Meter --> 10.63 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
V = 2*A*L --> 2*0.79*10.63
Evaluating ... ...
V = 16.7954
STEP 3: Convert Result to Output's Unit
16.7954 Cubic Meter --> No Conversion Required
FINAL ANSWER
16.7954 Cubic Meter <-- Volume of Conductor
(Calculation completed in 00.004 seconds)

Credits

Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verified by Payal Priya
Birsa Institute of Technology (BIT), Sindri
Payal Priya has verified this Calculator and 1900+ more calculators!

15 Wire Parameters Calculators

Line Losses using Area of X-Section(Single-Phase Two-Wire OS)
Go Line Losses = (4*Length of Overhead AC Wire*Resistivity*(Power Transmitted^2))/(Area of Overhead AC Wire*(Maximum Voltage Overhead AC^2)*((cos(Phase Difference))^2))
Length of Wire using Area of X-Section(Single-Phase Two-Wire OS)
Go Length of Overhead AC Wire = (Area of Overhead AC Wire*Maximum Voltage Overhead AC^2*Line Losses*cos(Phase Difference)^2)/(4*Resistivity*(Power Transmitted^2))
Length using Line Losses (Single-Phase Two-Wire OS)
Go Length of Overhead AC Wire = (Line Losses*Area of Overhead AC Wire*(Maximum Voltage Overhead AC*cos(Phase Difference))^2)/(4*(Power Transmitted^2)*Resistivity)
Area of X-Section using Line Losses (Single-Phase Two-Wire OS)
Go Area of Overhead AC Wire = (4*Resistivity*Length of Overhead AC Wire*Power Transmitted^2)/(Line Losses*(Maximum Voltage Overhead AC*cos(Phase Difference))^2)
Area of X-Section(Single-Phase Two-Wire OS)
Go Area of Overhead AC Wire = (4*(Power Transmitted^2)*Resistivity*Length of Overhead AC Wire)/(((cos(Phase Difference))^2)*Line Losses*(Voltage Overhead AC^2))
Volume of Conductor Material using Line Losses (Single-Phase Two-Wire OS)
Go Volume of Conductor = (8*Resistivity*(Power Transmitted*Length of Overhead AC Wire)^2)/(Line Losses*(Maximum Voltage Overhead AC*cos(Phase Difference))^2)
Constant using Load Current (Single-Phase Two-Wire OS)
Go Constant Overhead AC = (2*Current Overhead AC^2*cos(Phase Difference)^2*Resistivity*Length of Overhead AC Wire^2)/Line Losses
Constant using Line Losses (Single-Phase Two-Wire OS)
Go Constant Overhead AC = (4*Resistivity*(Power Transmitted*Length of Overhead AC Wire)^2)/(Line Losses*(Maximum Voltage Overhead AC)^2)
Constant(Single-Phase Two-Wire OS)
Go Constant Overhead AC = (4*(Power Transmitted^2)*Resistivity*Length of Overhead AC Wire)/(Line Losses*(Voltage Overhead AC^2))
Length using Load Current (Single-Phase Two-Wire OS)
Go Length of Overhead AC Wire = (Line Losses*Area of Overhead AC Wire)/(2*(Current Overhead AC)^2*Resistivity)
Volume of Conductor Material using Load Current (Single-Phase Two-Wire OS)
Go Volume of Conductor = (4*(Current Overhead AC^2)*Resistivity*(Length of Overhead AC Wire^2))/(Line Losses)
Area of X-Section using Load Current (Single-Phase Two-Wire OS)
Go Area of Overhead AC Wire = (2*Current Overhead AC^2*Resistivity*Length of Overhead AC Wire)/(Line Losses)
Volume of Conductor Material(Single-Phase Two-Wire OS)
Go Volume of Conductor = 2*Area of Overhead AC Wire*Length of Overhead AC Wire
Line Losses(Single-Phase Two-Wire OS)
Go Line Losses = (2)*((Current Overhead AC)^2)*Resistance Overhead AC
Line Losses using Load Current (Single-Phase Two-Wire OS)
Go Line Losses = 2*Resistance Overhead AC*(Current Overhead AC)^2

Volume of Conductor Material(Single-Phase Two-Wire OS) Formula

Volume of Conductor = 2*Area of Overhead AC Wire*Length of Overhead AC Wire
V = 2*A*L

What is the value of maximum voltage and volume of conductor material in this system?

The volume of conductor material required in this system is 2/cos2θ times that of 2-wire d.c.system with the one conductor earthed. The maximum voltage between conductors is vm so that r.m.s. value of voltage between them is vm/√2.

How to Calculate Volume of Conductor Material(Single-Phase Two-Wire OS)?

Volume of Conductor Material(Single-Phase Two-Wire OS) calculator uses Volume of Conductor = 2*Area of Overhead AC Wire*Length of Overhead AC Wire to calculate the Volume of Conductor, The Volume of Conductor Material(single-Phase two-Wire OS) formula is defined as the 3-dimensional space enclosed by a conductor material of a single-phase two-wire overhead system. Volume of Conductor is denoted by V symbol.

How to calculate Volume of Conductor Material(Single-Phase Two-Wire OS) using this online calculator? To use this online calculator for Volume of Conductor Material(Single-Phase Two-Wire OS), enter Area of Overhead AC Wire (A) & Length of Overhead AC Wire (L) and hit the calculate button. Here is how the Volume of Conductor Material(Single-Phase Two-Wire OS) calculation can be explained with given input values -> 16.7954 = 2*0.79*10.63.

FAQ

What is Volume of Conductor Material(Single-Phase Two-Wire OS)?
The Volume of Conductor Material(single-Phase two-Wire OS) formula is defined as the 3-dimensional space enclosed by a conductor material of a single-phase two-wire overhead system and is represented as V = 2*A*L or Volume of Conductor = 2*Area of Overhead AC Wire*Length of Overhead AC Wire. Area of Overhead AC Wire is defined as the cross-sectional area of the wire of an AC supply system & Length of Overhead AC Wire is the total length of the wire from one end to other end.
How to calculate Volume of Conductor Material(Single-Phase Two-Wire OS)?
The Volume of Conductor Material(single-Phase two-Wire OS) formula is defined as the 3-dimensional space enclosed by a conductor material of a single-phase two-wire overhead system is calculated using Volume of Conductor = 2*Area of Overhead AC Wire*Length of Overhead AC Wire. To calculate Volume of Conductor Material(Single-Phase Two-Wire OS), you need Area of Overhead AC Wire (A) & Length of Overhead AC Wire (L). With our tool, you need to enter the respective value for Area of Overhead AC Wire & Length of Overhead AC Wire and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Volume of Conductor?
In this formula, Volume of Conductor uses Area of Overhead AC Wire & Length of Overhead AC Wire. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Volume of Conductor = (8*Resistivity*(Power Transmitted*Length of Overhead AC Wire)^2)/(Line Losses*(Maximum Voltage Overhead AC*cos(Phase Difference))^2)
  • Volume of Conductor = (4*(Current Overhead AC^2)*Resistivity*(Length of Overhead AC Wire^2))/(Line Losses)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!