How to Calculate Work done per cycle in High pressure Compressor during incomplete intercooling given suction volume?
Work done per cycle in High pressure Compressor during incomplete intercooling given suction volume calculator uses Work Done per cycle = (Polytropic Index for Compression/(Polytropic Index for Compression-1))*Discharge Pressure of Low Pressure Compressor*Discharge Volume*((Discharge Pressure of High Pressure Compressor/Discharge Pressure of Low Pressure Compressor)^((Polytropic Index for Compression-1)/Polytropic Index for Compression)-1) to calculate the Work Done per cycle, The Work done per cycle in High pressure Compressor during incomplete intercooling given suction volume formula is defined as the amount of work done per cycle by the High-Pressure compressor in a Multistage compressor when Intercooling is incomplete and Suction Volume is given. Work Done per cycle is denoted by w symbol.
How to calculate Work done per cycle in High pressure Compressor during incomplete intercooling given suction volume using this online calculator? To use this online calculator for Work done per cycle in High pressure Compressor during incomplete intercooling given suction volume, enter Polytropic Index for Compression (nc), Discharge Pressure of Low Pressure Compressor (P2), Discharge Volume (V2) & Discharge Pressure of High Pressure Compressor (P3) and hit the calculate button. Here is how the Work done per cycle in High pressure Compressor during incomplete intercooling given suction volume calculation can be explained with given input values -> 910180.5 = (1.2/(1.2-1))*700000*1.6*((1500000/700000)^((1.2-1)/1.2)-1).