Actual Discharge given Pump Slippage Solution

STEP 0: Pre-Calculation Summary
Formula Used
Actual Discharge of Pump for Gear Pump = Theoretical Discharge of Pump in Gear Pump-Pump Slippage
Qga = Qgp-S
This formula uses 3 Variables
Variables Used
Actual Discharge of Pump for Gear Pump - (Measured in Cubic Meter per Second) - Actual discharge of pump for Gear Pump is the actual amount of liquid pumped out in a minute.
Theoretical Discharge of Pump in Gear Pump - (Measured in Cubic Meter per Second) - Theoretical Discharge of Pump in Gear Pump is the volume of liquid pumped out in unit time.
Pump Slippage - (Measured in Cubic Meter per Second) - Pump slippage is the difference between the theoretical discharge and the actual discharge.
STEP 1: Convert Input(s) to Base Unit
Theoretical Discharge of Pump in Gear Pump: 0.843 Cubic Meter per Second --> 0.843 Cubic Meter per Second No Conversion Required
Pump Slippage: 0.42 Cubic Meter per Second --> 0.42 Cubic Meter per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Qga = Qgp-S --> 0.843-0.42
Evaluating ... ...
Qga = 0.423
STEP 3: Convert Result to Output's Unit
0.423 Cubic Meter per Second --> No Conversion Required
FINAL ANSWER
0.423 Cubic Meter per Second <-- Actual Discharge of Pump for Gear Pump
(Calculation completed in 00.020 seconds)

Credits

Created by Sagar S Kulkarni
Dayananda Sagar College of Engineering (DSCE), Bengaluru
Sagar S Kulkarni has created this Calculator and 200+ more calculators!
Verified by Vaibhav Malani
National Institute of Technology (NIT), Tiruchirapalli
Vaibhav Malani has verified this Calculator and 200+ more calculators!

12 Gear Pumps Calculators

Theoretical Discharge given Outer and Inner Gear Diameter
Go Theoretical Discharge of Pump in Gear Pump = pi/4*(Outer Diameter of Gear Teeth^2-Inner Diameter of Gear Teeth^2)*Angular Speed of Driving Member in Gear Pump
Width of Rotor given Volumetric Displacement
Go Width of Rotor = (4*Theoretical Volumetric Displacement in Gear Pump)/(pi*(Outer Diameter of Gear Teeth^2-Inner Diameter of Gear Teeth^2))
Theoretical Volumetric Displacement of External Gear Pump
Go Theoretical Volumetric Displacement in Gear Pump = pi/4*Width of Rotor*(Outer Diameter of Gear Teeth^2-Inner Diameter of Gear Teeth^2)
Pump Slippage Percentage
Go Pump Slippage Percentage = ((Theoretical Discharge of Pump in Gear Pump-Actual Discharge of Pump for Gear Pump)/Theoretical Discharge of Pump in Gear Pump)*100
Angular Speed given Theoretical Discharge and Volumetric Displacement
Go Angular Speed of Driving Member in Gear Pump = Theoretical Discharge of Pump in Gear Pump/Theoretical Volumetric Displacement in Gear Pump
Theoretical Discharge of External Gear Pump
Go Theoretical Discharge of Pump in Gear Pump = Theoretical Volumetric Displacement in Gear Pump*Angular Speed of Driving Member in Gear Pump
Volumetric Efficiency of Gear Pumps
Go Volumetric Efficiency of Pump = Actual Discharge of Pump for Gear Pump/Theoretical Discharge of Pump in Gear Pump*100
Actual Discharge given Volumetric Efficiency and Theoretical Discharge
Go Actual Discharge of Pump for Gear Pump = (Volumetric Efficiency of Pump*Theoretical Discharge of Pump in Gear Pump)
Theoretical Discharge given Volumetric Efficiency and Actual Discharge
Go Theoretical Discharge of Pump in Gear Pump = Actual Discharge of Pump for Gear Pump/Volumetric Efficiency of Pump
Theoretical Discharge given Pump Slippage
Go Theoretical Discharge of Pump in Gear Pump = Pump Slippage+Actual Discharge of Pump for Gear Pump
Actual Discharge given Pump Slippage
Go Actual Discharge of Pump for Gear Pump = Theoretical Discharge of Pump in Gear Pump-Pump Slippage
Pump Slippage
Go Pump Slippage = Theoretical Discharge of Pump in Gear Pump-Actual Discharge of Pump for Gear Pump

Actual Discharge given Pump Slippage Formula

Actual Discharge of Pump for Gear Pump = Theoretical Discharge of Pump in Gear Pump-Pump Slippage
Qga = Qgp-S

What is discharge of a pump?

Discharge of a pump is defined as the amount of a liquid pumped out in unit time. It is also called as flow capacity of a pump.

How to Calculate Actual Discharge given Pump Slippage?

Actual Discharge given Pump Slippage calculator uses Actual Discharge of Pump for Gear Pump = Theoretical Discharge of Pump in Gear Pump-Pump Slippage to calculate the Actual Discharge of Pump for Gear Pump, Actual Discharge given Pump Slippage can be calculated by considering the pump slippage. Pump slippage refers to the difference between the theoretical or ideal discharge and the actual discharge due to internal losses and inefficiencies in the pump. Actual Discharge of Pump for Gear Pump is denoted by Qga symbol.

How to calculate Actual Discharge given Pump Slippage using this online calculator? To use this online calculator for Actual Discharge given Pump Slippage, enter Theoretical Discharge of Pump in Gear Pump (Qgp) & Pump Slippage (S) and hit the calculate button. Here is how the Actual Discharge given Pump Slippage calculation can be explained with given input values -> 0.42 = 0.843-0.42.

FAQ

What is Actual Discharge given Pump Slippage?
Actual Discharge given Pump Slippage can be calculated by considering the pump slippage. Pump slippage refers to the difference between the theoretical or ideal discharge and the actual discharge due to internal losses and inefficiencies in the pump and is represented as Qga = Qgp-S or Actual Discharge of Pump for Gear Pump = Theoretical Discharge of Pump in Gear Pump-Pump Slippage. Theoretical Discharge of Pump in Gear Pump is the volume of liquid pumped out in unit time & Pump slippage is the difference between the theoretical discharge and the actual discharge.
How to calculate Actual Discharge given Pump Slippage?
Actual Discharge given Pump Slippage can be calculated by considering the pump slippage. Pump slippage refers to the difference between the theoretical or ideal discharge and the actual discharge due to internal losses and inefficiencies in the pump is calculated using Actual Discharge of Pump for Gear Pump = Theoretical Discharge of Pump in Gear Pump-Pump Slippage. To calculate Actual Discharge given Pump Slippage, you need Theoretical Discharge of Pump in Gear Pump (Qgp) & Pump Slippage (S). With our tool, you need to enter the respective value for Theoretical Discharge of Pump in Gear Pump & Pump Slippage and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Actual Discharge of Pump for Gear Pump?
In this formula, Actual Discharge of Pump for Gear Pump uses Theoretical Discharge of Pump in Gear Pump & Pump Slippage. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Actual Discharge of Pump for Gear Pump = (Volumetric Efficiency of Pump*Theoretical Discharge of Pump in Gear Pump)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!