Air supply required in Grit Chamber Solution

STEP 0: Pre-Calculation Summary
Formula Used
Air supply required = Chosen air supply/Length of grit chamber
As = A/L
This formula uses 3 Variables
Variables Used
Air supply required - (Measured in Cubic Meter per Second) - Air supply required in the aerated grit chamber.
Chosen air supply - (Measured in Square Meter per Second) - Chosen air supply is the amout of air chosen to supply in grit chamber.
Length of grit chamber - (Measured in Meter) - Length of grit chamber is the longer dimension of the grit chamber.
STEP 1: Convert Input(s) to Base Unit
Chosen air supply: 10 Square Meter per Second --> 10 Square Meter per Second No Conversion Required
Length of grit chamber: 20 Meter --> 20 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
As = A/L --> 10/20
Evaluating ... ...
As = 0.5
STEP 3: Convert Result to Output's Unit
0.5 Cubic Meter per Second --> No Conversion Required
FINAL ANSWER
0.5 Cubic Meter per Second <-- Air supply required
(Calculation completed in 00.004 seconds)

Credits

Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

16 Design of an Aerated Grit Chamber Calculators

Width using Length of Grit Chamber
Go Width of grit chamber = (Volume/(Depth of grit chamber*Length of grit chamber))
Depth given Length of Grit Chamber
Go Depth of grit chamber = (Volume/(Length of grit chamber*Width of grit chamber))
Length of Grit Chamber
Go Length of grit chamber = (Volume/(Width of grit chamber*Depth of grit chamber))
Volume using Length of Grit Chamber
Go Volume = (Length of grit chamber*Width of grit chamber*Depth of grit chamber)
Width of Grit Chamber
Go Width of grit chamber = (Selected width ratio*Depth of grit chamber)
Selected Width-Ratio given Width of Grit Chamber
Go Selected width ratio = Width of grit chamber/Depth of grit chamber
Chosen Depth given Width of Grit Chamber
Go Depth of grit chamber = Width of grit chamber/Selected width ratio
Chamber Length using Air supply required
Go Length of grit chamber = (Chosen air supply/Air supply required)
Chosen Air Supply given Air supply required
Go Chosen air supply = Air supply required*Length of grit chamber
Air supply required in Grit Chamber
Go Air supply required = Chosen air supply/Length of grit chamber
Assumed Grit Quantity given Volume of Aerated Grit Chamber
Go Assumed grit quantity = (Volume/Volumetric Flow Rate)
Volume Flow Rate given Volume of Aerated Grit Chamber
Go Volumetric Flow Rate = (Volume/Assumed grit quantity)
Volume of Each Grit Chamber
Go Volume = (Peak flow rate*Detention time)/(7.48*24*60)
Peak Flow Rate given Volume of Each Grit Chamber
Go Peak flow rate = (Volume*7.48*24*60)/Detention time
Detention Time given Volume of each Grit Chamber
Go Detention time = (Volume*7.48*24*60)/Peak flow rate
Volume of Aerated Grit Chamber
Go Volume = Assumed grit quantity*Volumetric Flow Rate

Air supply required in Grit Chamber Formula

Air supply required = Chosen air supply/Length of grit chamber
As = A/L

What is grit chamber ?

Grit chambers are long narrow tanks that are designed to slow down the flow so that solids such as sand, coffee grounds, and eggshells will settle out of the water.

How to Calculate Air supply required in Grit Chamber?

Air supply required in Grit Chamber calculator uses Air supply required = Chosen air supply/Length of grit chamber to calculate the Air supply required, The Air supply required in Grit Chamber calculates the value of air supply required when we have prior information of chosen air supply and length of grit chamber. Air supply required is denoted by As symbol.

How to calculate Air supply required in Grit Chamber using this online calculator? To use this online calculator for Air supply required in Grit Chamber, enter Chosen air supply (A) & Length of grit chamber (L) and hit the calculate button. Here is how the Air supply required in Grit Chamber calculation can be explained with given input values -> 0.5 = 10/20.

FAQ

What is Air supply required in Grit Chamber?
The Air supply required in Grit Chamber calculates the value of air supply required when we have prior information of chosen air supply and length of grit chamber and is represented as As = A/L or Air supply required = Chosen air supply/Length of grit chamber. Chosen air supply is the amout of air chosen to supply in grit chamber & Length of grit chamber is the longer dimension of the grit chamber.
How to calculate Air supply required in Grit Chamber?
The Air supply required in Grit Chamber calculates the value of air supply required when we have prior information of chosen air supply and length of grit chamber is calculated using Air supply required = Chosen air supply/Length of grit chamber. To calculate Air supply required in Grit Chamber, you need Chosen air supply (A) & Length of grit chamber (L). With our tool, you need to enter the respective value for Chosen air supply & Length of grit chamber and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!