Allowable Static Thrust Load on Groove Solution

STEP 0: Pre-Calculation Summary
Formula Used
Allowable static thrust load on groove wall = (Conversion factor*Shaft Diameter*Depth of groove*pi*Tensile Yield Strength of Groove Material)/(Factor of Safety*Reduction Factor)
Ftg = (C*D*d*pi*σsy)/(fs*Φ)
This formula uses 1 Constants, 7 Variables
Constants Used
pi - Archimedes' constant Value Taken As 3.14159265358979323846264338327950288
Variables Used
Allowable static thrust load on groove wall - (Measured in Newton) - Allowable static thrust load on groove wall is the amount of measured force directed at and from a turning mechanism.
Conversion factor - Conversion factor is to account for change from metric units used in development of the formula.
Shaft Diameter - (Measured in Meter) - The Shaft Diameter is defined as the diameter of the hole in the iron laminations that contains the shaft.
Depth of groove - (Measured in Meter) - Depth of groove is the perpendicular distance from a real or calculated reference plane defined by edges of two adjacent ribs to the lowest point in the groove.
Tensile Yield Strength of Groove Material - (Measured in Pascal) - Tensile yield strength of groove material is the stress that causes a material to lose its elastic behavior.
Factor of Safety - Factor of Safety expresses how much stronger a system is than it needs to be for an intended load.
Reduction Factor - Reduction Factor is constant term used as factor for load calculation.
STEP 1: Convert Input(s) to Base Unit
Conversion factor: 1.486 --> No Conversion Required
Shaft Diameter: 3.6 Meter --> 3.6 Meter No Conversion Required
Depth of groove: 3.5 Meter --> 3.5 Meter No Conversion Required
Tensile Yield Strength of Groove Material: 9 Pascal --> 9 Pascal No Conversion Required
Factor of Safety: 2.8 --> No Conversion Required
Reduction Factor: 0.85 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Ftg = (C*D*d*pi*σsy)/(fs*Φ) --> (1.486*3.6*3.5*pi*9)/(2.8*0.85)
Evaluating ... ...
Ftg = 222.435847848229
STEP 3: Convert Result to Output's Unit
222.435847848229 Newton --> No Conversion Required
FINAL ANSWER
222.435847848229 222.4358 Newton <-- Allowable static thrust load on groove wall
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by sanjay shiva
national institute of technology hamirpur (NITH ), hamirpur , himachal pradesh
sanjay shiva has created this Calculator and 100+ more calculators!
Verifier Image
Verified by Anshika Arya
National Institute Of Technology (NIT), Hamirpur
Anshika Arya has verified this Calculator and 2500+ more calculators!

5 Load Capacities of Groove Calculators

Tensile Yield Strength of Groove Material given allowable Static Thrust Load on Groove
​ Go Tensile Yield Strength of Groove Material = (Factor of Safety*Reduction Factor*Allowable static thrust load on groove wall)/(Conversion factor*Shaft Diameter*pi*Depth of groove)
Shaft Diameter given allowable Static Thrust Load on Groove
​ Go Shaft Diameter = (Allowable static thrust load on groove wall*Factor of Safety*Reduction Factor)/(Conversion factor*Depth of groove*pi*Tensile Yield Strength of Groove Material)
Allowable Static Thrust Load on Groove
​ Go Allowable static thrust load on groove wall = (Conversion factor*Shaft Diameter*Depth of groove*pi*Tensile Yield Strength of Groove Material)/(Factor of Safety*Reduction Factor)
Allowable impact loading on groove
​ Go Allowable impact loading on groove = (Allowable static thrust load on groove wall*Depth of groove)/2
Allowable Static Thrust Load given Allowable Impact Loading on Groove
​ Go Allowable static thrust load on groove wall = Allowable impact loading on groove*2/Depth of groove

Allowable Static Thrust Load on Groove Formula

Allowable static thrust load on groove wall = (Conversion factor*Shaft Diameter*Depth of groove*pi*Tensile Yield Strength of Groove Material)/(Factor of Safety*Reduction Factor)
Ftg = (C*D*d*pi*σsy)/(fs*Φ)

What is static thrust load?

Static thrust load is the amount of measured force directed at and from a turning mechanism. As the mechanism such as a gear turns on a shaft, there is both load emitted from the gear in the direction it is turning as well as against the shaft it is turning on, either forward or to the rear.

How to Calculate Allowable Static Thrust Load on Groove?

Allowable Static Thrust Load on Groove calculator uses Allowable static thrust load on groove wall = (Conversion factor*Shaft Diameter*Depth of groove*pi*Tensile Yield Strength of Groove Material)/(Factor of Safety*Reduction Factor) to calculate the Allowable static thrust load on groove wall, The Allowable Static Thrust Load on Groove formula is defined as the amount of measured force directed at and from a turning mechanism. Allowable static thrust load on groove wall is denoted by Ftg symbol.

How to calculate Allowable Static Thrust Load on Groove using this online calculator? To use this online calculator for Allowable Static Thrust Load on Groove, enter Conversion factor (C), Shaft Diameter (D), Depth of groove (d), Tensile Yield Strength of Groove Material sy), Factor of Safety (fs) & Reduction Factor (Φ) and hit the calculate button. Here is how the Allowable Static Thrust Load on Groove calculation can be explained with given input values -> 207.6068 = (1.486*3.6*3.5*pi*9)/(2.8*0.85).

FAQ

What is Allowable Static Thrust Load on Groove?
The Allowable Static Thrust Load on Groove formula is defined as the amount of measured force directed at and from a turning mechanism and is represented as Ftg = (C*D*d*pi*σsy)/(fs*Φ) or Allowable static thrust load on groove wall = (Conversion factor*Shaft Diameter*Depth of groove*pi*Tensile Yield Strength of Groove Material)/(Factor of Safety*Reduction Factor). Conversion factor is to account for change from metric units used in development of the formula, The Shaft Diameter is defined as the diameter of the hole in the iron laminations that contains the shaft, Depth of groove is the perpendicular distance from a real or calculated reference plane defined by edges of two adjacent ribs to the lowest point in the groove, Tensile yield strength of groove material is the stress that causes a material to lose its elastic behavior, Factor of Safety expresses how much stronger a system is than it needs to be for an intended load & Reduction Factor is constant term used as factor for load calculation.
How to calculate Allowable Static Thrust Load on Groove?
The Allowable Static Thrust Load on Groove formula is defined as the amount of measured force directed at and from a turning mechanism is calculated using Allowable static thrust load on groove wall = (Conversion factor*Shaft Diameter*Depth of groove*pi*Tensile Yield Strength of Groove Material)/(Factor of Safety*Reduction Factor). To calculate Allowable Static Thrust Load on Groove, you need Conversion factor (C), Shaft Diameter (D), Depth of groove (d), Tensile Yield Strength of Groove Material sy), Factor of Safety (fs) & Reduction Factor (Φ). With our tool, you need to enter the respective value for Conversion factor, Shaft Diameter, Depth of groove, Tensile Yield Strength of Groove Material, Factor of Safety & Reduction Factor and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Allowable static thrust load on groove wall?
In this formula, Allowable static thrust load on groove wall uses Conversion factor, Shaft Diameter, Depth of groove, Tensile Yield Strength of Groove Material, Factor of Safety & Reduction Factor. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Allowable static thrust load on groove wall = Allowable impact loading on groove*2/Depth of groove